




版權說明:本文檔由用戶提供并上傳,收益歸屬內容提供方,若內容存在侵權,請進行舉報或認領
文檔簡介
目錄1工程概況····························································222編制依據····························································223臨電組織管管理·······················································34施工用電負負荷運算···················································45配電箱安裝裝技術要求及及保護措施····································666線路敷設技技術要求···················································77現場照明措措施·······················································78防雷與接地地·························································79安全措施····························································8810雨季施工工措施······················································11附1臨電平面面布置圖附2臨時用電電作業危險分分析工程概況本項目包括66個單體,分分別是:倉庫庫D7011-D7022、消防廢水水緩沖池D7705、叉車車及蓄電池充充電區D7006、變配配電站D7007以及管廊廊D708,35kv開關站、門門衛、地磅1和22為已建,倉倉庫D7003和DD704屬屬于項目二期期建設范圍。本本項目與廠區區內其他項目目共用大門,停停車場,門衛衛及主要管廊廊。編制依據在建設工程施工工現場供、用用電中貫徹執執行“安全第一,預預防為主”的方針,確確保在施現場場供、用電中中的人身安全全和設備安全全,并使施工工現場供、用用電設施的設設計、施工、運運行及維護做做到安全可靠靠,確保質量量,經濟合理理,特制定本本施工方案。序號規范、法規編號備注1施工現場臨時用用電安全技術術規范JGJ46-220052建設工程施工現現場消防安全全技術規范GB507200-201113建設工程施工現現場供用電安安全規范GB501944-934建筑電氣安裝工工程施工質量量驗收規范GB503033-200225手持式電動工具具的管理、使使用、檢查和和維修安全技技術規程6特種作業人員安安全技術考核核管理規則7安全生產文明施施工手冊臨電組織管理機構公司成立用電安安全領導小組組:施工現場場成立以項目目經理為首的的用電安全管管理小組,直直接負責臨電電安全工作。公司成立安全用用電專職保障障隊伍:為保保證現場用電電安全,由安安全經理負責責專業電工和和安全人員參參加,對現場場臨時用電及及時檢查。職責項目經理負責臨臨電實用組織織工作,主持持雨期施工生生產會,對雨雨期施工所需需的人、財、物物等進行統籌籌安排。技術人員負責編編制臨電施工工技術措施大大綱,審核項項目安全用電電施工技術措措施,并進行行詳細指導;;協助項目經經理組織協調調好臨電施工工,并跟蹤檢檢查質量、安安全。安全組負責檢查查、監督措施施的落實、執執行情況。安全人員職責確保臨電安裝過過程中不留隱隱患,及時對對存在問題的的部位進行改改進,保證施施工人員用電電安全。指導本單位用電電人員遵守安安全用電規程程,不得將沒沒有用電資格格的人員派往往現場安裝用用電設備。對現場施工人員員進行教育,不不得私自移動動、亂接臨電電器具,發現現違反用電規規程的人員及及時制止,并并做相應處罰罰。3.4臨設設布置本項目施工用電電,按照業主主提出的方案案,采用項目目正式電源電電纜10kvv加臨時變壓壓器,作為施施工電源,由由于電纜敷設設路徑按照正正式工程要求求,現階段不不具備施工用用電的條件,為為此,項目決決定采用柴油油發電機臨時時供電,解決決施工用電的的需求,根據據現場實際情情況結合電纜纜敷設的時間間和可行性,進進過現場勘查查,我們決定定10kv電電纜敷設采用用界區外正式式埋管敷設,界界區內8#到到10#井之之間采用正式式埋管路徑敷敷設,高壓電電纜進到界區區內在8#電電纜井出地面面,采用腳手手架架空敷設設的辦法,將將多余電纜放放到項目界區區內的土堆上上面,周邊用用腳手桿圍住住掛警告牌,選選擇這個地點點是綜合考慮慮的結果,110kv變壓壓器放在界區區內,將來正正式變壓器運運行前再拆除除高壓電纜沿沿電纜埋管,敷敷設到7077變壓器。樁樁機施工采用用柴油發電機機。臨時用電電計算就不考考慮樁基施工工,只考慮除除樁基外的其其他用電符荷荷施工用電負荷計計算計算說明考慮全工地所使使用的機械動動力設備,其其他電氣工具具及照明用電電量。采用施工總進度度計劃中施工工高峰階段同同時用電的機機械設備的最最大數量。本工程機械設備備計劃在生產產廠房施工時時采用的1臺樁基施工工為用電高峰峰期,高峰階階段同時用電電的機械設備備數量最高,現現場所使用的的機械動力設設備,其他電電氣工具及照照明用電高峰峰時期的數量量《用電高峰峰期間現場用用電量一覽表表》。負荷計算用電高峰期間現現場用電量一一覽表序號機械或設備名稱型號規格數量額定功率(KWW)總功率(KW)1照明201202打樁機21503003焊機10202004清水泵122225鋼筋切斷機GQ-4014.04.06鋼筋彎曲機GW4014.04.07鋼筋套絲機2-414.04.08木工圓盤鋸MJ22511.51.59交流弧焊機BX-30052010010砂輪切割機Θ50055.527.511熱熔焊接機23.06.012直流弧焊機BX3-5000-24.48.813電動套絲機B-15020.71.414卷板機12.02.015單平咬口機?12.52.516聯合咬口機?=0.8-44mm11.51.517氬弧焊機LTN25533.610.818焊條烘干箱YZH2-155011.81.819焊條恒溫箱14.04.020電稿東誠-35040.20.821電錘東誠-28040.20.822抽水泵WQD-18--0.7540.753.023塔吊QTZ40125.8225.82本工程施工用電電負荷計算如如下:施工臨時用電高高峰設備表::(1)塔吊25.8821臺(2)鋼筋切斷斷機4KWW11臺(3)鋼筋彎曲曲機4KW1臺臺(7)電焊機200kww110臺(8)零星電動動工具15KKW(9)照明用電電200KW電動機額定功率率:∑P1=255.82+44+4+155=48.88KW電焊機額定功率率:ΣP2=2000kw照明用電負荷::∑P3=200KW供電設備總需要要容量:S=1.05**(K1*∑∑P1/COOSφ1+K2**∑P2+K33*∑P3/COOSφ2)=1.05**(0.6**48.8//0.75++0.6*2220+0..8*20//0.85)=199KVVA選擇360KVVA變壓器一一臺。計算電流:I==KS/1..732U==0.8*1199*10000/1..732*3380=2441.88AA根據查表得知,995平方電纜纜的安全載流流量為2988安培,故此此,選擇VVV-YJV2223x995+2x550電纜作為為項目施工電電源。配電箱安裝技術術要求及保護護措施配電箱的采購嚴嚴格按JGJJ46-20005《施工工現場臨時用用電安全技術術規范》等規規范標準進行行。現場配電箱四周周設置防護欄欄桿及防砸棚棚。防護欄桿桿及防砸棚采采用建管部們們的推薦產品品。欄桿刷紅紅白色警示漆漆,籠門上鎖鎖,并有警示示標志。籠體體安裝在基礎礎上,距地220cm以上上,內填砂土土,配有4LL干粉滅火器器一臺。現場臨電須有專專人維修,每每天定期檢查查。總配電箱相應設設在靠近電源源的地區,分分配電相應裝裝設在或負荷荷相對集中的的地區,分配配電箱與開關關箱的距離不不得超過300M,開關箱箱與其控制的的固定式用電電設備的水平平距離不宜超超過3M;電箱、開關箱應應裝設在干燥燥、通風及常常溫場所,不不得裝設在易易受外來固體體物撞擊、強強烈振動、液液體浸濺及熱熱源烘烤的場場所,否則,需需作特殊防護護處理;配電箱、開關箱箱周圍應有足足夠二人同時時工作的空間間和通道,不不得堆放任何何妨礙操作、維維修的物品;;配電箱、開關箱箱應裝設端正正、牢固、移移動式配電箱箱,開關箱應應裝設在堅固固的支架上;;配電箱、開關箱箱內的電器(含含插座),應應按其規定的的位置固定在在電器安裝板板上,不得歪歪斜和松動。線路敷設技術要要求線路敷設方式為為明敷和直埋埋相結合,電電纜干線嚴禁禁在地面明設設,并應避免免機械損傷和和介質腐蝕;;電纜直埋時其表表面距地面的的距離不宜小小于0.6MM,電纜上下下應鋪軟土或或砂土,其厚厚度不得小于于100MMM,加硬質物物覆蓋。埋地敷設電纜的的接頭應設在在地面上的接接線盒內,接接線盒應能防防水、防塵、防防機械損傷,并并應遠離易燃燃、易腐蝕場場所;電纜與熱力管道道(管溝)及及熱力設備平平行,交叉應應采取隔熱措措施,使周圍圍土壤的溫升升不超過100℃;橡套電纜架空敷敷設時,應沿沿墻壁或電桿桿設置,并用用絕緣子固定定,嚴禁使用用金屬裸線作作綁線,固定定點間距不得得小于2.55M。現場照明措施施工現場封閉空空間內疏散照照明由區域內內專用照明控控制箱低壓(336V)供電電;照明燈具具功率不大于于60W。施工現場照明采采用鏑燈,安安裝在施工現現場的鏑燈必必須要有可靠靠的接地保護護,每一個鏑鏑燈必須有腳腳手管搭設的的燈架,鏑燈燈電源線用絕絕緣子固定好好,且保證施施工現場的照照片足夠。施工現場小面積積照明采用移移動式1KWW密閉式碘鎢鎢燈(帶防護護罩),碘鎢鎢燈架必須有有接地保護,碘碘鎢燈嚴禁架架設固定在易易燃易爆處。辦公室設專用支支路配電箱控控制,箱內裝裝有靈敏的漏漏電保護器,室室內電線全部部采用穿管或或者明線槽敷敷設,燈頭距距地不得低于于2.4m,燈燈泡不大于660W,相線線經開關控制制。室內配線必須采采用絕緣導線線,采用瓷瓶瓶、瓷夾等固固定,距地面面高度不得小小于2.5mm。防雷與接地接地體安裝工藝藝:鍍鋅圓鋼DN550mm,壁壁厚3.5mmm,扁鋼440X4mmm。接地體頂面埋設設深度不應小小于0.6mm,鋼管接地地體垂直配置置。接地體長度2..5m,相互互之間為5mm。接地體埋設位置置距建筑物不不宜小于1..5m,遇有有垃圾灰渣等等地埋設接地地體時,應換換土并分層夯夯實。接地體采用焊接接,焊接處焊焊縫飽滿,并并有足夠的機機械強度,不不得有夾渣、咬咬肉、虛焊、氣氣孔等缺陷。焊焊接處藥皮敲敲凈后,刷瀝瀝青做防腐處處理。鍍鋅扁鋼焊接不不小于其寬度度的2倍,且且至少3個,棱棱邊焊接敷設設時調直,煨煨彎不得過死死,并立放。鍍鋅鋼管焊接時時,為了連接接可靠,除在在其接觸部位位兩側焊接外外,應將扁鋼鋼彎成弧形焊焊接。遇有白灰焦渣層層,應做砂漿漿全面保護。采用化學方法降降低土壤電阻阻率注意保護接地體體鍍鋅層人工接地體安裝裝接地體加工:切切割鋼管的長長不小于2..5m,遇松松軟土壤時,可可切成斜面,遇遇硬質土時,可可加工成圓錐錐形(入土部部位120mmm處)。挖溝:深為0..8-1m,寬寬為0.5mm。溝上部稍稍寬,底部漸漸窄,溝底如如有石子應及及時清除。接地體安裝:溝溝挖好后,應應立即安裝接接地體和敷設設接地扁鋼,防防止土方坍塌塌,將接地體體放在溝的中中心線上,手手錘打入地中中,一人扶著著接地體,一一人打錘,接接地體管頭可可加一個護管管帽,防止打打劈。手錘敲敲打平穩,錘錘擊正中不得得打偏,與地地面保護垂直直,當接地體體頂端距離地地面0.6mm時,停止打打入。扁鋼敷設:調直直扁鋼,放入入溝內,扁鋼鋼側放,與鋼鋼管上口反110cm處焊焊接,焊好后后,清除藥皮皮,刷瀝青,做做好防腐處理理,并將接地地線引出至需需要的位置。此做法適用于防防雷接地、保保護接地、工工作接地、重重復接地等。防防雷接地、保保護接地阻值值不大于4ΩΩ,重復接地地阻值不大于于10Ω。安全措施安全用電技術措措施及電氣防防火措施施工現場臨時用用電設備設置置、設備安裝裝、設備防護護、設備使用用及電氣設備備的操作、維維修必須符合合JGJ466-20055《施工現場場臨時用電安安全技術規范范》的要求;;電源進線(N線線)在1#總總計量配電箱箱處做重復接接地。在各總總級箱處另作作PE線(必必須采用黃———綠雙色線線)與N線自自總箱接地體體各自獨立敷敷設,嚴格與與相線、零線線相區別,杜杜絕混用;嚴禁部分電氣設設備做保護接接零,另一部部分設備做到到保護接地。整個施工現場必必須嚴格按三三級配電逐級級保護內容形形式布置:總總配電箱→分配電箱→開關箱→用電設備,二二級漏電保護護:分配電箱箱→開關箱設置置漏電保護。具具備分級保護護功能,開關關箱實行一機機一閘,在任任何情況下漏漏電保護器只只能通過工作作線,而不能能通過保護線線。電氣裝置置必須裝設端端正、牢固、完完好,不得拖拖地放置;導導線間接必須須絕緣包扎并并保證絕緣強強度、機械強強度。所有導導線與器具的的聯接必須壓壓接牢固可靠靠。配電箱的位置應應按本方案平平面布置示意意圖設置,盡盡力做到:靠近負荷中心;;進出線方便;與水源、火源保保持一定距離離,并要防止止地面低洼積積水。開關箱內所有開開關用明顯的的標志注明其其回路和控制制用電設備等等,嚴格按三三級配電,二二級漏電保護護(配電箱++開關箱)設設置配電開關關箱,使之具具有分級保護護功能。末端端形狀箱必須須安裝漏電保保護器,開關關箱做到一箱箱一閘一漏電電。漏電保護護器安裝運行行均應按規范范規定,漏電電保護器應使使用總公司選選擇的指定廠廠家產品,其其它非定點產產品不得安裝裝使用。根據據電器設備的的供電方式正正確選用漏電電保護器的額額定動作電流流應大于300MA,額定定動作時間應應大于0.11S。應充分分考慮到供電電線路、供電電方式、供電電電壓的特性性,漏電保護護器投入運行行后,應按規規定要求填寫寫運行紀錄,每每月至少二次次在通電的狀狀態下監測漏漏電開關動作作是否可靠,雷雷雨季節應加加強試驗次數數。配電箱、開關箱箱進出線口一一律設在箱體體的下底,而而且有防絕緣緣損壞措施,做做到有門、有有鎖、有防雨雨、防砸及維維護措施,箱箱內沒雜物。做做到PE線與與N線嚴格分分開使用,PPE線嚴禁通通過工作電流流。線路敷設根據環環境靈活運用用,既要考慮慮減小線路負負荷矩,又要要整齊的敷設設保持線路的的有條不紊和和相對的固定定,原則上必必須做到地埋埋的有保護,架架空、沿墻敷敷設,按《施施工現場臨時時用電安全技技術規范》相相關條文執行行。移動電器設備及及產生振動的的電器設備其其PE線與金金屬外殼的連連接點不得少少于二點,電電源線必須有有防脫落措施施。局部照明明原則上采用用36V低壓壓系統,采用用漏電保護器器,外露金屬屬部分必須與與PE線可靠靠連接。從臨時用電工程程開始到工程程竣工,所有有需新增的線線路安裝、使使用,必須報報審,批準后后方可開始安安裝。專業工長在本方方案開始實施施前,必須組組織專業電工工學習本方案案及技術交底底,進行職業業道德、責任任心的教育,掌掌握本施工方方案和安全用用電技術措施施的總體意圖圖、技術措施施及注意事項項。專業工長長必須在本方方案實施前完完成書面的技技術交底,并并要求在技術術交底書上履履行交底人與與被交底人的的簽字手續,并并注明交底日日期。安全運行與維修修管理制度建立用電安全崗崗位責任制,明明確各級用電電負責人;所有配電箱均應應標明其名稱稱、用途,并并作分路登記記,所有配電電箱門應配鎖鎖,所有配電電箱和開關箱箱應由專人負負責;用電設施的運行行及維護,必必須配備足夠夠的常用電器器絕緣工具,并并按有關規定定,定期進行行電器性能檢檢驗;電氣絕絕緣工具嚴禁禁挪作它用;;對配電箱、開關關箱進行檢查查、維修時,必必須將前一級級相應的電源源開關分閘斷斷電,并懸掛掛停電標志牌牌,嚴禁帶電電作業;現場需要用電時時,必須提前前提出申請,經經用電管理部部門批準,通通知維護班組組進行接線,接接引電源工作作必須由持證證維修電工進進行,并設專專人進行監護護;熔斷器的熔體更更換時,嚴禁禁用不按條例例規定的熔體體代替,配電電箱、開關箱箱的進線和出出線不得承受受外力;手持電動工具必必須設置經檢檢驗后動作靈靈敏的漏電保保安器;安全運行電工管管理制度現場值班人員必必須持證上崗崗,掌握運行行知識和操作作技術;現場值班維修管管理人員必須須熟知全部供供電線路走向向和各種機械械設備的銘牌牌參數,各種種設備的安全全過流保護選選配合理;值班人員在工作作期間不得擅擅自離開工作作崗位,有事事向班長請假假,工作時間間嚴禁酗酒;;重要施工項目要要在現場巡視視,發生故障障及時處理;;夜間照明應在施施工場地設專專人值班,遇遇到故障應一一人檢修,一一人監護;所有配電箱、開開關箱每半月月檢查和維修修一次,檢查查維修時,必必須停電并按按規定穿絕緣緣鞋、戴絕緣緣手套,必須須使用電工絕絕緣工具;維修電工必須持持有本市勞動動部門核發有有效的操作證證。從臨時用電工程程開始至工程程竣工,本著著以防為主、防防患未然的精精神,建立巡巡視、安檢、電電器維修制度度,工作內容容是:漏電開開關動作是否否可靠,電氣氣設備絕緣電電阻值是否符符合要求,電電氣設備金屬屬外殼的PEE線連接是否否可靠,各類類用電人員使使用是否正確確,是否做到到人走斷電,當當有開道挖溝溝作業時是否否有損地埋電電纜的可能,并并通知作業人人員注意事項項,以防意外外。當遇有大大風雷雨時應應加強巡視,在在發生短路故故障后,應重重點檢查有關關的線路,防防止留下隱患患,對現場配配電箱應檢查查所處位置是是否妥當,必必要時考慮移移位,對流動動箱的檢查應應注意其安全全使用的可靠靠性,對于大大面積停電事事故處理應分分為三個步驟驟進行:線路、設備功率率,和配置各各類保護電器器及線纜,加加強電器設備備的絕緣、運運行電流的檢檢測,發現問問題及時處理理。經常進行電氣防防火知識教育育,提高各類類用電人員的的電氣防火意意識。合理設設置防雷裝置置,電氣裝置置周圍禁止堆堆放易燃、易易爆物品并配配置絕緣滅火火器材(四氯氯化碳或
溫馨提示
- 1. 本站所有資源如無特殊說明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請下載最新的WinRAR軟件解壓。
- 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請聯系上傳者。文件的所有權益歸上傳用戶所有。
- 3. 本站RAR壓縮包中若帶圖紙,網頁內容里面會有圖紙預覽,若沒有圖紙預覽就沒有圖紙。
- 4. 未經權益所有人同意不得將文件中的內容挪作商業或盈利用途。
- 5. 人人文庫網僅提供信息存儲空間,僅對用戶上傳內容的表現方式做保護處理,對用戶上傳分享的文檔內容本身不做任何修改或編輯,并不能對任何下載內容負責。
- 6. 下載文件中如有侵權或不適當內容,請與我們聯系,我們立即糾正。
- 7. 本站不保證下載資源的準確性、安全性和完整性, 同時也不承擔用戶因使用這些下載資源對自己和他人造成任何形式的傷害或損失。
最新文檔
- 影視錄放設備的智能抗干擾優化技術發展現狀考核試卷
- 竹材采運項目管理與團隊溝通考核試卷
- 碩士答辯精準指南
- 江蘇省江都區丁伙中學2024-2025學年初三下學期第二次質量檢測試題(化學試題)含解析
- 天津農學院《營養生理學》2023-2024學年第二學期期末試卷
- 嘉興學院《基礎西班牙語(Ⅱ)》2023-2024學年第二學期期末試卷
- 四川省廣安市華鎣市市級名校2024-2025學年初三全真模擬考試(一)生物試題試卷含解析
- 沈陽航空航天大學北方科技學院《進階英語(2)》2023-2024學年第一學期期末試卷
- 江蘇省徐州市市區部分校2024-2025學年下學期初三物理試題第三次月考考試試卷含解析
- 山東省青島市42中學2025年初三第一次模擬考試適應性測試化學試題含解析
- 科技創業孵化園項目書專題培訓課件
- 市供銷社規章制度匯編
- 辦公用品及辦公耗材售后維護服務方案
- 思想道德與法治 第三章
- 信息光學課件
- 北師大版數學八年級下冊全冊同步練習附答案
- 開放水域潛水員理論知識考試試題與答案
- 機械設計基礎課程設計題目范文
- 報價單報價表
- 職業衛生檔案全套
- 大象版小學《科學》實驗目錄
評論
0/150
提交評論