




版權說明:本文檔由用戶提供并上傳,收益歸屬內容提供方,若內容存在侵權,請進行舉報或認領
文檔簡介
1、打開交換機端口,查看ip地址首先等入交換機brocade8Gb:USERID> switchshowswitchName: brocade8GbswitchType: 73.6switchState: Online switchMode: NativeswitchRole: PrincipalswitchDomain: 1switchId: fffc01switchWwn: 10:00:00:27:f8:66:79:03zoning: OFFswitchBeacon: OFFIndex Port Address Media Speed State Proto= 0 0 010000 id
2、 N8 No_Light FC Disabled (Persistent) 1 1 010100 cu N8 Online FC F-Port 10:00:00:90:fa:17:dc:20 2 2 010200 cu N8 Online FC F-Port 10:00:00:90:fa:17:dd:d2 3 3 010300 cu N8 Online FC F-Port 10:00:00:90:fa:17:db:a0 4 4 010400 cu N8 Online FC F-Port 10:00:00:90:fa:17:33:1a 5 5 010500 cu N8 Online FC F-P
3、ort 10:00:00:90:fa:17:de:28 6 6 010600 cu N8 Online FC F-Port 10:00:00:90:fa:17:dc:80 7 7 010700 cu N8 Online FC F-Port 10:00:00:90:fa:17:de:48 8 8 010800 cu N8 Online FC F-Port 10:00:00:90:fa:17:de:02 9 9 010900 cu N8 Online FC F-Port 10:00:00:90:fa:17:dd:2a 10 10 010a00 cu N8 Online FC F-Port 10:0
4、0:00:90:fa:17:dc:e6 11 11 010b00 cu N8 Online FC F-Port 10:00:00:90:fa:17:30:dc 12 12 010c00 cu N8 Online FC F-Port 10:00:00:90:fa:17:de:10 13 13 010d00 cu N8 Online FC F-Port 10:00:00:90:fa:17:dc:0a 14 14 010e00 cu N8 Online FC F-Port 10:00:00:90:fa:17:33:82 15 15 010f00 id N8 No_Light FC Disabled
5、(Persistent) 16 16 011000 - N8 No_Module FC Disabled (Persistent) 17 17 011100 - N8 No_Module FC Disabled (Persistent) 18 18 011200 - N8 No_Module FC Disabled (Persistent) 19 19 011300 - N8 No_Module FC Disabled (Persistent)brocade8Gb:USERID> version 查看版本Kernel: 2.6.14.2 Made on: Thu Aug 9 21:10:
6、00 2012Flash: Fri Mar 15 14:33:49 2013brocade8Gb:USERID> switchdisable 關閉交換機模式brocade8Gb:USERID> ag -modeenable開啟ag模式WARNING: Access Gateway mode changes the standard behavior of the switch. Please check Access Gateway Administrator's Guide before proceeding.Enabling agmode will remove all
7、 the configuration data on the switchincluding zoning configuration and security database. Please backup yourconfiguration using configupload.This operation will reboot the switch.Do you want to continue? (yes, y, no, n): no y這個時候會提示重新啟動Access Gateway mode was enabled successfullySwitch is being reb
8、ooted.客戶只有在0號段口上有一根尾纖,這里做的都是把端口全部綁定在0號口上由于關閉了交換機模式,交換機上無法再顯示wwn號了.brocade8Gb:USERID> switchshowswitchName: brocade8GbswitchType: 73.6switchState: Online switchMode: Access Gateway ModeswitchWwn: 10:00:00:27:f8:66:bd:d8switchBeacon: OFFIndex Port Address Media Speed State Proto= 0 0 010000 id N8 N
9、o_Light FC 1 1 010100 cu AN No_Sync FC Disabled (N-Port Offline for F-Port) 2 2 010200 cu AN No_Sync FC Disabled (N-Port Offline for F-Port) 3 3 010300 cu AN No_Sync FC Disabled (N-Port Offline for F-Port) 4 4 010400 cu AN No_Sync FC Disabled (N-Port Offline for F-Port) 5 5 010500 cu AN No_Sync FC D
10、isabled (N-Port Offline for F-Port) 6 6 010600 cu AN No_Sync FC Disabled (N-Port Offline for F-Port) 7 7 010700 cu AN No_Sync FC Disabled (N-Port Offline for F-Port) 8 8 010800 cu AN No_Sync FC Disabled (N-Port Offline for F-Port) 9 9 010900 cu AN No_Sync FC Disabled (N-Port Offline for F-Port) 10 1
11、0 010a00 cu AN No_Sync FC Disabled (N-Port Offline for F-Port) 11 11 010b00 cu AN No_Sync FC 12 12 010c00 cu AN No_Sync FC 13 13 010d00 cu AN No_Sync FC 14 14 010e00 cu AN No_Sync FC 15 15 010f00 id N8 No_Light FC 16 16 011000 - N8 No_Module FC 17 17 011100 - N8 No_Module FC 18 18 011200 - N8 No_Mod
12、ule FC 19 19 011300 - N8 No_Module FC brocade8Gb:USERID> LOCAL : SEND0: window-change (rows: 24, cols: 80) brocade8Gb:USERID> ag mapshow 這個是默認的設置N_Port Configured_F_Ports Current_F_Ports Failover Failback PG_ID PG_Name- 0 1;2 None 1 1 0 pg0 15 3;4 None 1 1 0 pg0 16 5;6;7 None 1 1 0 pg0 17 8;9
13、None 1 1 0 pg0 18 10;11 None 1 1 0 pg0 19 12;13;14 None 1 1 0 pg0-brocade8Gb:USERID> ag -mapdel 15 "3;4"F_Port to N_Port mapping has been updated successfullybrocade8Gb:USERID> ag -mapdel 16 "5;6;7"F_Port to N_Port mapping has been updated successfullybrocade8Gb:USERID>
14、ag -mapdel 17 "8;9" F_Port to N_Port mapping has been updated successfullybrocade8Gb:USERID> ag -mapdel 18 "10;11"F_Port to N_Port mapping has been updated successfullybrocade8Gb:USERID> ag -mapdel 19 "12;13;14"F_Port to N_Port mapping has been updated successfull
15、ybrocade8Gb:USERID> ag -mapadd 0"3;4;5;6;7;8;9;10;11;12;13;14"要注意空格USAGE: ag -mapadd <N_Port> "< fport; fport >" Adds specified list of F_Ports to the mapping for a given N_Port. It will add the current to the existing mappings if any for that N_Port. An F_Port can
16、not be mapped to more than one N_Port at the same timebrocade8Gb:USERID> ag -mapadd 0"3;4" USAGE: ag -mapadd <N_Port> "< fport; fport >" Adds specified list of F_Ports to the mapping for a given N_Port. It will add the current to the existing mappings if any for th
17、at N_Port. An F_Port cannot be mapped to more than one N_Port at the same timebrocade8Gb:USERID> ag -mapadd 0 "3;4;5;6;7;8;9;10;11;12;13;14"F_Port to N_Port mapping has been updated successfully 成功brocade8Gb:USERID> ag -mapshowN_Port Configured_F_Ports Current_F_Ports Failover Failba
18、ck PG_ID PG_Name- 0 1;2;3;4;5; None 1 1 0 pg0 6;7;8;9;10; 11;12;13;14 15 None None 1 1 0 pg0 16 None None 1 1 0 pg0 17 None None 1 1 0 pg0 18 None None 1 1 0 pg0 19 None None 1 1 0 pg0brocade8Gb:USERID> switchshowswitchName: brocade8GbswitchType: 73.6switchState: Online switchMode: Access Gateway
19、 ModeswitchWwn: 10:00:00:27:f8:66:c1:ddswitchBeacon: OFFIndex Port Address Media Speed State Proto= 0 0 010000 id N8 No_Light FC 1 1 010100 cu AN No_Sync FC Disabled (N-Port Offline for F-Port) 2 2 010200 cu AN No_Sync FC Disabled (N-Port Offline for F-Port) 3 3 010300 cu AN No_Sync FC Disabled (N-P
20、ort Offline for F-Port) 4 4 010400 cu AN No_Sync FC Disabled (N-Port Offline for F-Port) 5 5 010500 cu AN No_Sync FC Disabled (N-Port Offline for F-Port) 6 6 010600 cu AN No_Sync FC Disabled (N-Port Offline for F-Port) 7 7 010700 cu AN No_Sync FC Disabled (N-Port Offline for F-Port) 8 8 010800 cu AN
21、 No_Sync FC Disabled (N-Port Offline for F-Port) 9 9 010900 cu AN No_Sync FC Disabled (N-Port Offline for F-Port) 10 10 010a00 cu AN No_Sync FC Disabled (N-Port Offline for F-Port) 11 11 010b00 cu AN No_Sync FC 12 12 010c00 cu AN No_Sync FC 13 13 010d00 cu AN No_Sync FC 14 14 010e00 cu AN No_Sync FC
22、 15 15 010f00 id N8 No_Light FC 16 16 011000 - N8 No_Module FC 17 17 011100 - N8 No_Module FC 18 18 011200 - N8 No_Module FC 19 19 011300 - N8 No_Module FCbrocade8Gb:USERID> portenable 0 打開端口 或是switchenablebrocade8Gb:USERID> switchshowswitchName: brocade8GbswitchType: 73.6switchState: Online s
23、witchMode: Access Gateway ModeswitchWwn: 10:00:00:27:f8:66:bd:d8switchBeacon: OFFIndex Port Address Media Speed State Proto= 0 0 010000 id N4 Online FC N-Port 20:0c:00:0d:ec:c1:f1:41 0x7a002b 1 1 010100 cu N8 Online FC F-Port 10:00:00:90:fa:17:32:fe 0x7a003d 2 2 010200 cu N8 Online FC F-Port 10:00:00:90:fa:17:db:ea 0x7a003e 3 3 010300 cu N8 Online FC F-Port 10:00:
溫馨提示
- 1. 本站所有資源如無特殊說明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請下載最新的WinRAR軟件解壓。
- 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請聯系上傳者。文件的所有權益歸上傳用戶所有。
- 3. 本站RAR壓縮包中若帶圖紙,網頁內容里面會有圖紙預覽,若沒有圖紙預覽就沒有圖紙。
- 4. 未經權益所有人同意不得將文件中的內容挪作商業或盈利用途。
- 5. 人人文庫網僅提供信息存儲空間,僅對用戶上傳內容的表現方式做保護處理,對用戶上傳分享的文檔內容本身不做任何修改或編輯,并不能對任何下載內容負責。
- 6. 下載文件中如有侵權或不適當內容,請與我們聯系,我們立即糾正。
- 7. 本站不保證下載資源的準確性、安全性和完整性, 同時也不承擔用戶因使用這些下載資源對自己和他人造成任何形式的傷害或損失。
最新文檔
- 監理工程師職業素養與法律法規遵守考核試卷
- 入院護理宣教
- 食管癌護理查房
- 蘇州工藝美術職業技術學院《韓語語法三》2023-2024學年第一學期期末試卷
- 江蘇省宿遷2024-2025學年初三全真模擬考試(一)生物試題試卷含解析
- 烏魯木齊市沙依巴克區2025年五下數學期末調研模擬試題含答案
- 江西省樟樹市2025年初三4月教學質量檢測試題生物試題含解析
- 江西財經大學現代經濟管理學院《基礎俄語Ⅳ》2023-2024學年第一學期期末試卷
- 民辦四川天一學院《醫學文獻檢索》2023-2024學年第一學期期末試卷
- 吉林省白山市江源縣2025年數學五下期末考試模擬試題含答案
- 腎臟移植課件
- 食品生產許可審查通則解讀課件
- 美麗的晉祠-完整版課件
- 醫院“雙培養”制度
- 時區與區時課件
- 許慎《說文解字》(全文)
- DB34∕T 1948-2013 建設工程造價咨詢檔案立卷標準
- 通用門座機安裝工藝2
- 企業集團財務管理綜合練習計算
- 養老機構服務高質量115項明細
- 圓管涵結構計算
評論
0/150
提交評論