HP常用存儲介紹
issue1.0第二章HP存儲產品介紹
HP存儲AUTORAIDHP存儲FC60
HP存儲VA系列HP存儲DS2405HP存儲EVA系列
AutoRaid12H特性(性能指標)磁盤插槽:12個處理器:1-2個電源模塊:2-3個風扇:3個存儲容量: 37.8GB(max,使用4.3GB磁盤) 82.3GB(max,使用9.1GB磁盤) 182.8GB(max,使用18.2GB磁盤)支持RAID:動態地在1/0,或5之間變換支持接口標準:FWDSCSI,或通過FC-SCSI多路轉換器使用光纖通道(FiberChannel)接口功耗:870VA(最大值)散熱量:2560BTUs/小時AutoRaid12H前視圖
注意AutoRaid的硬盤安裝順序應從上至下,從左到右,否則會影響系統的I/O性能。
ModuleLayoutFanmodulesDiskmodulesPowersupplymodulesControllermodules*Minimumsupportedconfiguration:2PowerSupplies4DiskModules(4or9Gbyte)3FanModules1ControllerModules
RearPanelFeaturesControllerX,SCSIConnector1ControllerX,SCSIConnector2ControllerY,SCSIConnector1ControllerY,SCSIConnector23ACPowerConnectorsSCSIbusresetswitchesareundertherearcover.SeetheServiceManualforsettings.ControllershaveseparateFWDSCSIconnectors,canbeonsame/separatebussesOneACconnectorforeachpowermodule,canconnecttoseparateUPSorPDU
ArrayModuleMapPowerSupplies-P1,P2,P3DiskModules-A1-A6,B1-B6FanModules-F1,F2,F3Controllers-X,YLettersareembossednexttoslotsControlpanelmessagesrefertothismappingSCSIaddressingispresetonthebackplane(exceptControllers)ControllersareaddressedthroughutilitiesortheControlPanel
ControllerModules(cont.)Twocontrollermodulesprovideredundancy每個控制器都有個分離的SCSIID同一總線的控制器SCSIID不能相同SCSI地址和參數可以通過軟件或控制面板設置
Controllers包括96MB的NVRAM/DRAM控制器之間NVRAM是鏡像的;如果一個失敗,另一個會接管工作NVRAM包括所有的logical到physicalmemorymaps和寫cache一個正確的shutdown會復制NVRAMmaps到每個安裝的硬盤上SCSIAddressingNVRAMBasicsNote:NVRAM是電池保護的.永遠小心移動或更換控制卡的動作.
ConnectingSCSICabling擴展總線是68針高密SCSI類型每個總線必須要用一個SCSI終結器控制器之間連接的SCSI線纜大概0.5米內部和外部的SCSI線纜不能超過25米SCSI68-pinto68-pinCable(HBAtoY2)SCSI68-pinto68-pinCable(Y1toX1)SCSIPassiveDifferentialTerminator(X2)ConnectingSCSICablingConnectingSCSICablingConnectingSCSICablingN4000雙機連單個AutoRaid
UsingtheControlPanelSimpleconfigurationmenusPressMENUtoselecttheMainMenu.Press+or-toscrolltoamenu.PressENTERtoselectamenu.Press+or-toscrollthroughthemenuitems.PressENTERtoselectadisplayeditem.Press+or-thenpressENTERtoselectvaluesforatask,enable/disable,andconfirm/cancel.ControlPanelMenu
ControlPanelLights&Messages初始化失敗則狀態燈保持熄滅.狀態燈熄滅則陣列不可用.橙色燈亮代表有錯誤,但是控制器可以和主機通訊即使開始重建,橙色等仍然會點亮,直到壞盤被從陣列中分離.錯誤信息會在控制面板中顯示出來ColorIndicationOffNopower,arraynotavailable,orinitializingSolidGreenDiskarrayready.SolidAmberDiskarrayself-testorarrayfault.RandomFlashingGreenDiskarrayI/Oactivity.RandomFlashingAmberDiskarrayI/Oactivity,WarningMode.
ModuleStatusLightsForfans,powermodules,anddiskmodules綠燈表示工作正常.不亮表示沒有上電,或磁盤沒有活動數據橙色燈不是在自檢時點亮表示有故障當插拔模塊時要小心,防止數據活電源丟失Forcontrollermodules綠燈表示待機狀態,沒有活動數據隨機閃爍表示工作正常熄滅代表沒有上電,沒有自檢或不可認的SCSI總線橙色燈常亮表示有故障
ApropershutdownprotectsthedataProperShutdown關閉陣列,使其對主機不可用執行關閉動作會復制maps信息到所有的硬盤正常的關閉后,控制器和磁盤是相互獨立狀態關閉過程完成后,控制器發送NVRAM信息到硬盤,然后進入離線狀態關閉動作可以通過
ControlPanel->Utilities,或
pressingthepowerbuttononthearray.
A"SystemWarning"indicatesanerrorcondition.Thearrayremainson-line.Correcttheerrorbeforemakinganyconfigurationchanges.
/opt/hparray/bin/ARMServerARMServerCommandUtilitiesDetailedmanpagesexistforeachofthesecommands,andalsoforARMServer.TheArrayMonitorDaemon(arraymond)monitorsthesysteminregularintervalsCommandNameDescription
arraydspProvidesinformationabouttheconfigurationandoperatingstateofthearray.
arraymgrConfigurestheoveralloperatingcharacteristicsofthearray,suchastheSCSIprotocol,cachingandactivehotspare.
arraycfgConfiguresthe"logical"parametersofthearray,primarilyLUNconfiguration,alongwithdiskutilization.
arrayfmtFormatsthearray.
arrayrbldUsedtoinitiate,terminateandevaluatetherebuildofadiskinthearray.
arraydsp-iThiscommandisusedtodisplaytheserialnumbersofallarraysknownbythehost.ARMServercommandstypicallyrequirean<array-id>,whichiseitherthearrayserialnumber,orthearray'scharacterdevicefilename.Youmightthenchoosetocommandtosetupashorteridentifier:#exporta1=000000786B74OR#a1=000000786B74Theidentifier$a1cannowbeusedtoidentifythearrayratherthantypinginthelengthyserialnumber.#arraydsp-iArraysknowntotheARMServer:arrayswithS/N:000000786B74Displayarrayserialnumber(s):#arraydsp-RRescanthebus:Findthearrayidentifiers:#ioscan-fn-Cdisk
ArraydspCommandSummaryCommandsusedtoviewarraysettingsarraydsp Nooption,displaysgeneralarrayinformation.arraydsp-i Displaysallarrayscurrentlyknownbythehost.arraydsp-l DisplaysLUNspecificinformation.arraydsp-d Displaysdiskinformation.arraydsp-s Displaysgeneralsettingsinformation.arraydsp-v DisplaysRAID0/1capacity.arraydsp-a Quickviewofallconfigurationandstatusinformation.arraydsp-c Displayscontrollerinformation.arraydsp-h Displayshardwareinformation.arraydsp-m Displaysdetailedperformancemetricsbydate&time.SeeManpagesforadditionalinformationonarraydspoptions
arraydsp<array-id>ViewinggeneralarrayinformationUSESAMManagerAutoraidClickingonanyofthemoduleimagesprovidesinformationforthatmoduleinthelowerleftcornerofthescreen.Greenstatuslightsaredisplayedforgoodworkingmodules,amberisdisplayedforfailures,andnolightisdisplayedformissingmodules.Itisimportanttonotethatthedisplayisnotupdatedrealtime.USESAMManagerAutoraidAutoRaid使用注意事項磁盤陣列是高可用性設備,但是一樣也可能發生嚴重故障,造成數據完全丟失的災難性后果,所以任何高可用性設備也不能取代數據備份,系統管理員一定要做好有效的數據備份。當AutoRaid陣列系統啟動后或運行過程中有任何部件的指示黃燈變亮不滅,說明陣列系統正在報警。這時請及時與惠普公司或專業人員聯系,千萬不要輕易關閉陣列電源或重新啟動系統,以免早造成數據丟失等難以挽回的后果。雖然AutoRaid中的磁盤模塊允許帶電熱插拔操作。但是磁盤的位置有一定的次序,并且在每次拔插后,磁盤組需要一定的時間進行重構,因此在陣列有數據的情況下,不要隨意拔插磁盤,特別禁止交換磁盤的位置。磁盤陣列是按照長時間穩定運行的模式設計的。所以在運行條件具備的情況下,建議盡量減少開,關機次數,否則會影響系統的壽命。第二章HP存儲產品介紹
HP存儲AUTORAIDHP存儲FC60
HP存儲VA系列HP存儲DS2405HP存儲EVA系列
FC60/SC10特性
磁盤插槽:每個SC10可插10塊硬盤,每個FC60最多可接6個SC10
處理器:1-2個電源模塊:2個風扇組件:2個 支持的硬盤容量:9.1GB,18.2GB,36GB
存儲容量:最大可支持36GB*10*6(SC10)
支持RAID1,1/0,5
接口標準:光纖通道(FibreChannel)
功耗: FC60180W(MAX) SC10467W(MAX)
FC60/SC10外觀說明
FCControllerDiagramArrayControllersControllerFansControllerBatteriesPowerSuppliesPowerSupplyFansSC10DiskEnclosureDisksPowerSuppliesFansBusControlCardsSC10前、后視圖SC10DIPSwitchSC10兩種總線結構
FULLBUSa.Full-bus模式智能通過一個BCC接入到盤柜的所有硬盤.b.一個盤柜的兩個BCC共有四個SCSI外接接口.c.Full-bus模式的2個BCC是相互冗余的.
SPLITBUSSplit-bus模式允許在一個盤柜中做磁盤鏡像.b.Split-bus模式使用很少的SCSIID,提高了總線性能.BatteryControllersFansController
LEDsFC60控制柜前視圖LEDsFC60控制柜后視圖FC60HA環境FC60MaximumConfigurationFC60HighPerformance/LowCostConfigOptimus`ConfigurationSPUFCAdapterAFCAdapterBFCAL-BLVDSCSILVDSCSIFCAL-ALUN0LUN1LUN2LUN3LUN4OptimusControllerAControllerBMegatronJBODBCC1BCC2SingleSPU,singlearrayoftwocontrollers&1JBOD,RAID-1RecommendedOptimus`HAConfigurationMegatronJBODSPUFCAdapterAFCAdapterBFCAL-BLVDSCSILVDSCSIFCAL-ALUN01234OptimusControllerAControllerBBCC1BCC2BCC2BCC157689SingleSPU,singlearrayoftwocontrollers&2JBODs,RAID-1RecommendedOptimus`HAConfiguration
SPUFCAdapterAFCAdapterBFCAL-BLVDSCSILVDSCSIFCAL-AOptimusControllerAControllerBMegatronJBODBCC2BCC1BCC1BCC1BCC2BCC2LUN01LUN92345678SingleSPU,singlearrayoftwocontrollers&3JBODs,RAID-5AlternateOptimus`HAConfiguration:SPUFCAdapterAFCAdapterBFCAL-BFCAL-ALUN0LUN1LUN2LUN3LUN4OptimusControllerAControllerBLUN5LUN6LUN7MegatronJBODBCC1BCC1BCC1BCC1BCC1BCC1LUN8LUN9BCC2BCC2BCC2BCC2BCC2BCC2SingleSPU,singlearrayoftwocontrollers&6JBODs,RAID-5FC60控制柜指示燈SC10磁盤柜指示燈
/opt/hparray/bin/AM60SrvrAM60SrvrCommandUtilitiesDetailedmanpagesexistforeachofthesecommands,andalsoforAM60Srvr.TheArrayMonitorDaemon(arraymond)monitorsthesysteminregularintervalsCommandNameDescription
amdspProvidesinformationabouttheconfigurationandoperatingstateofthearray.
ammgrConfigurestheoveralloperatingcharacteristicsofthearray,suchastheControlActive,cachingandactivehotspare.
amcfgmanagesLUN(logicaldrive)configurationonthediskarray
amutilcontrolsvariousdiskarraymanagementfunctions.Suchasflashled.
amrbldUsedtoinitiate,terminateandevaluatetherebuildofadiskinthearray.
amdsp-iThiscommandisusedtodisplaytheserialnumbersofallarraysknownbythehost.AM60Srvrcommandstypicallyrequirean<array-id>,whichiseitherthearrayserialnumber,orthearray'scharacterdevicefilename.Youmightthenchoosetocommandtosetupashorteridentifier:#exporta1=0000C00A0B8090ECE
OR#a1=0000C00A0B8090ECETheidentifier$a1cannowbeusedtoidentifythearrayratherthantypinginthelengthyserialnumber.#amdsp-iArraysknowntotheAM60Srvr:arrayswithS/N:0000C00A0B8090ECEDisplayarrayserialnumber(s):#amdsp-RRescanthebus:Findthearrayidentifiers:#ioscan-fnCdiskcommands
ArraydspCommandSummaryCommandsusedtoviewarraysettingsamdsp的格式:amdsp<option><arrayid|alias>amdsp Nooption,displaysgeneralarrayinformation.amdsp-i Displaysallarrayscurrentlyknownbythehost.amdsp-l DisplaysLUNspecificinformation.amdsp-d Displaysdiskinformation.amdsp-s Displaysdiskarraystateinformation.amdsp-a Quickviewofallconfigurationandstatusinformation.amdsp-c Displayscontrollerinformation.amdsp-h Displayshardwareinformation.SeeManpagesforadditionalinformationonamdspoptionsamdsp–a<array-id>#amdsp–a000C00A0B8090ECEVendorID=HPProductID=A5277AArrayID=000C00A0B8090ECEArrayalias=array
ArrayState=READYServername=gbm2Arraytype=3Mfg.ProductCode=348-0040789DiskspaceusageTotalphysical=271.4GBAllocatedtoLUNs=169.4GBUsedasHotspare=33.9GBUnallocated(availforLUNs)=0.0GB
VendorID=HPProductID=A5277AArrayID=000C00A0B8090ECEArrayalias=array
B)useSAMManagerFC60useSAMManagerFC60FC60使用注意事項磁盤陣列是高可用性設備,但是一樣也可能發生嚴重故障,造成數據完全丟失的災難性后果,所以任何高可用性設備也不能取代數據備份,系統管理員一定要做好有效的數據備份。當FC60陣列系統啟動后或運行過程中有任何部件的指示黃燈變亮不滅,說明陣列系統正在報警。這時請及時與惠普公司或專業人員聯系,千萬不要輕易關閉陣列電源或重新啟動系統,以免早造成數據丟失等難以挽回的后果。雖然FC60中的磁盤模塊允許帶電熱插拔操作。但是磁盤的位置有一定的次序,并且在每次拔插后,磁盤組需要一定的時間進行重構,因此在陣列有數據的情況下,不要隨意拔插磁盤,特別禁止交換磁盤的位置。磁盤陣列是按照長時間穩定運行的模式設計的。所以在運行條件具備的情況下,建議盡量減少開,關機次數,否則會影響系統的壽命。第二章HP存儲產品介紹
HP存儲AUTORAIDHP存儲FC60
HP存儲VA系列HP存儲DS2405HP存儲EVA系列
VA7100/VA7400可用性可擴展性和性能HPsurestore的中檔陣列產品
VA710015K/3KIOPs**1,080GB容量15個驅動器800MB/sec的背板18、36、73GB10&15KFC磁盤2.0GB高速緩存2個100MbsFC端口(主機)64個LUNVA管理
軟件VA740030K/10KIOPs**7.7TB容量105個驅動器800MB/sec的背板18、36、73GB10&15KFC磁盤2.0GB高速緩存2個200MbsFC端口(主機)1024個LUNVA管理軟件VA71001Gb/snativefibrechannelPerformance:(read)90MB/s,12.5KIOPscache,3KIOPsdisk1GBcachepercontroller15highperformancediskdrives3Uinastandard19”rack540GB36.1GBdisks1.1TB73GBdisksHP-UX11.0,11i,MPE/iX6.5,7.0(9/1),WinNT,Win2K,RH6.2,7.1,Solaris7.0,8.0,Netware,AIXnextMC/ServiceGuard,MicrosoftClusterServicesCertificationpending(paperworkhasbeensubmitted)TheVA7100-為中小企業的關鍵業務提供一個便捷的存儲空間管理設備VA74002Gb/snativefibrechannelPerformance:(read/write45Drive)180MB/s,30KIOPscache,8KIOPsdisk75MB/s,30KIOPscache,4KIOPsdisk1GBcachepercontroller105highperformancediskdrives3U/encl.inastandard19”rack3.8TBw/36.4GBdisks7.7TBw/73GBdisksHP-UX11.0,11i,MPE/iX6.5,7.0(9/1),WinNT,Win2K,RH6.2,7.1,Solaris7.0,8.0,Netware,AIXnextMC/ServiceGuardMicrosoftClusterServicesCertificationpending(paperworkwillsubmittedlateJuly)TheVA7400–為中小企業的關鍵業務提供一個便捷的存儲空間管理設備ProductoverviewArrayEnclosure:FrontPanel*Usethepointofapencil,penor
similarobjecttoaccessOn/Off
Switch
**Referencedesignatoractually
usedinCommandViewPower/StandbySwitch*SystemFaultLED(Amber)SystemPower/ActivityLED(Green)DiskDriveSlotNumber(1of15;8coveredbyHPlabel)DiskDrive(**D1-D15)DiskDriveFaultLED(Amber)ESDGroundPlug(BananaType)DiskDriveActivityLED(Green)ArrayEnclosure:RearPanel*ReferencedesignatoractuallyusedinCommandViewArrayControllerCard1(*C1)HOSTFCPortConnector1(*H1)FCLinkLEDs(Upper=Green;Lower=Amber)ArrayControllerCard1LEDs–CONTROLLER,BATTERY,DIMM1,DIMM2(Left=Green;Right=Amber)SerialConnectorPower/FanModule(*P1)Power/FanModuleLEDsACPowerConnectorArrayControllerCard2(*C2)battery:caution!電池充滿電后可以支持NVRAM的數據3天不失。如果電池不能夠充滿電,一般是電池壞了如果綠色的LED以5%的速度閃爍,說明電池在向DIMMmemory供電電池運行在25%到50%的額定功率,最大生命周期是6個月如果電池的工作溫度超過了25oC,它的生命周期將會嚴重縮短10.8V鋰電池智能電池.有自己單獨處理器不要將電池放置在陽光下,會嚴重影響電池的使用壽命第二章HP存儲產品介紹
HP存儲AUTORAIDHP存儲FC60HP存儲VA7XX
HP存儲DS2405
HP存儲EVA
DS2405背面AddressSwitchLCCActivityLEDLCCFaultLEDPort0FCConnectorPort1FCConnectorPowerSupplyLEDsLinkActiveLEDsPowerSupplyFanModuleACPowerConnectorLinkControlCard1(LCC)LinkControlCard2(LCC)DS2405移動和更換–現場更換單元
(FRUs):1-1-2
|3/_4/
5/6|DS2405Itemfromfig1Part#FRUdescriptionQtyperenclosureExchangeorReplaceFRUtype1A6191-69001DiskDrive,18GB,15krpm,512bytes/sector2-1510-15ECRU1A6192-69001DiskDrive,36GB,10krpm,512bytes/sector2-1510-15ECRU1A6193-69001DiskDrive,36GB,15krpm,512bytes/sector2-1510-15ECRU1A6194-69001DiskDrive,73GB,10krpm,512bytes/sector2-1510-15CRU2A6198-67014Diskfillerpanel0-110-5RCRU3A6214-67003Enclosu
溫馨提示
- 1. 本站所有資源如無特殊說明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請下載最新的WinRAR軟件解壓。
- 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請聯系上傳者。文件的所有權益歸上傳用戶所有。
- 3. 本站RAR壓縮包中若帶圖紙,網頁內容里面會有圖紙預覽,若沒有圖紙預覽就沒有圖紙。
- 4. 未經權益所有人同意不得將文件中的內容挪作商業或盈利用途。
- 5. 人人文庫網僅提供信息存儲空間,僅對用戶上傳內容的表現方式做保護處理,對用戶上傳分享的文檔內容本身不做任何修改或編輯,并不能對任何下載內容負責。
- 6. 下載文件中如有侵權或不適當內容,請與我們聯系,我們立即糾正。
- 7. 本站不保證下載資源的準確性、安全性和完整性, 同時也不承擔用戶因使用這些下載資源對自己和他人造成任何形式的傷害或損失。
最新文檔
- 激光工程師職業風險與防范考題試題及答案
- 安徽省導游試題及答案
- 編程公司面試題及答案
- 文化產業管理證書考試的教學方法與學習策略試題及答案
- 在專利申請中應注意的事項試題及答案
- 提高衛生管理考試能力的試題及答案
- 激光技術文獻閱讀與分析方法試題及答案
- 激光在飛機制造中的技術應用試題及答案
- 歷史高二廣東試題及答案
- 環境管理試題及答案解析
- 《兒科學》課件第9章第九節 腹瀉病
- 鋼筋混凝土外文翻譯文獻
- 項目2 動車組餐車乘務作業《高鐵動車餐飲服務》教學課件
- 致遠安全技術白皮書(簡版)
- 失禁性皮炎預防及護理PPT學習課件
- 新員工入職消防安全教育培訓記錄
- 愛寶s-990p打卡機說明書
- 廠區巡查記錄表
- 醫院管理者角色定位與執行力提升小時本
- 幼小銜接工作指導手冊【完整版】
- 新媒體運營全套PPT完整教學課件
評論
0/150
提交評論