




版權(quán)說明:本文檔由用戶提供并上傳,收益歸屬內(nèi)容提供方,若內(nèi)容存在侵權(quán),請(qǐng)進(jìn)行舉報(bào)或認(rèn)領(lǐng)
文檔簡(jiǎn)介
(建筑工程管理)廣東省細(xì)水霧滅火系統(tǒng)設(shè)計(jì)施工及驗(yàn)收規(guī)范(DBJT廣東省地方標(biāo)準(zhǔn)××××-××-××實(shí)施目次目次...................................................................................1前言..................................................................................21總則...............................................................................32術(shù)語(yǔ)、符號(hào).........................................................................32.1術(shù)語(yǔ)............................................................................32.2符號(hào)............................................................................43系統(tǒng)設(shè)計(jì)...........................................................................53.1一般規(guī)定.........................................................................53.2基本設(shè)計(jì)參數(shù).....................................................................54系統(tǒng)組件...........................................................................84.1一般規(guī)定.4.2組件要求.........................................................................85操作與控制.........................................................................106安全要求...........................................................................107施工與驗(yàn)收.........................................................................107.1基本規(guī)定.........................................................................107.2施工安裝.................................................................117.3系統(tǒng)調(diào)試.........................................................................127.4細(xì)水霧滅火系統(tǒng)工程質(zhì)量驗(yàn)收..........................................................12附錄A噴頭選型表附錄B雷諾曲線附錄C細(xì)水霧滅火系統(tǒng)子分部、分項(xiàng)工程劃分表附錄D檢驗(yàn)批質(zhì)量驗(yàn)收附錄E分項(xiàng)工程質(zhì)量驗(yàn)收附錄F細(xì)水霧滅火系統(tǒng)(子分部)工程質(zhì)量驗(yàn)收附錄G本規(guī)范用詞說明附:條文說明..........................................................................19前言本規(guī)范是根據(jù)廣東省建設(shè)廳粵建科函【2004】178號(hào)文的要求,由廣東省公安廳消防局、公安部天津消防研究所為主編單位會(huì)同有關(guān)參編單位共同編制。本規(guī)范以國(guó)家“九五重點(diǎn)科技攻關(guān)項(xiàng)目——細(xì)水霧滅火系統(tǒng)的研究成果為基礎(chǔ),結(jié)合對(duì)于不同場(chǎng)所和被保護(hù)對(duì)象的細(xì)水霧滅火系統(tǒng)工程應(yīng)用性實(shí)體滅火實(shí)驗(yàn)的實(shí)驗(yàn)數(shù)據(jù)和結(jié)論,參考?xì)W、美等國(guó)家相關(guān)規(guī)范和細(xì)水霧滅火系統(tǒng)產(chǎn)品的技術(shù)文件及工程應(yīng)用條件,針對(duì)廣東地區(qū)工業(yè)和民用建筑的特點(diǎn)及消防裝備要求,確定了細(xì)水霧滅火系統(tǒng)的應(yīng)用場(chǎng)所、系統(tǒng)組成、基本設(shè)計(jì)方法和系統(tǒng)施工、驗(yàn)收要求。驗(yàn)收、附錄。本規(guī)范屬首次制訂。主編單位:廣東省公安廳消防局公安部天津消防研究所參編單位:天津盛達(dá)安全科技實(shí)業(yè)公司廣州市公安消防局廣州市設(shè)計(jì)院廣州市地下鐵道設(shè)計(jì)研究院廣州市康華新衛(wèi)機(jī)電設(shè)備有限公司廣東勝捷消防設(shè)備有限公司規(guī)范起草人:1總則1.0.1為了合理設(shè)計(jì)細(xì)水霧滅火系統(tǒng),減少火災(zāi)危害,保護(hù)人民生命財(cái)產(chǎn)安全和生態(tài)環(huán)境,制定本規(guī)范。1.0.2本規(guī)范適用于廣東地區(qū)新建、擴(kuò)建、改建的建筑物、構(gòu)筑物中設(shè)置的細(xì)水霧滅火系統(tǒng)的設(shè)計(jì)、施工、驗(yàn)收。1.0.3本規(guī)范鼓勵(lì)采用通過國(guó)家消防檢測(cè)中心檢驗(yàn)合格的新技術(shù)、新設(shè)備、新產(chǎn)品、新材料的運(yùn)用。1.0.4細(xì)水霧滅火系統(tǒng)適用于撲救室內(nèi)及地下建筑物內(nèi)下列類型的火災(zāi):1.0.4.1可燃液體火災(zāi)(閃點(diǎn)不低于60°C);1.0.4.2固體表面火災(zāi);1.0.4.3油浸式電力變壓器火災(zāi);1.0.4.4計(jì)算機(jī)房、通信機(jī)房、控制室等火災(zāi);1.0.4.5圖書館、檔案館、博物館等火災(zāi);1.0.4.6配電室、電纜夾層、電纜隧道、柴油發(fā)電機(jī)房、燃?xì)廨啓C(jī)、燃油燃?xì)忮仩t房、直燃機(jī)房等火災(zāi);1.0.4.7其它適用細(xì)水霧自動(dòng)滅火系統(tǒng)進(jìn)行滅火或控火的火災(zāi)場(chǎng)所;1.0.5細(xì)水霧系統(tǒng)不能直接用于下列場(chǎng)所:1.0.5.1有遇水即發(fā)生爆炸或會(huì)產(chǎn)生大量有害物質(zhì)的場(chǎng)合,如鋰、鈉、鉀、鎂、鈦、鋯、鈾等金屬或其化合物;1.0.5.2有低溫液化氣體存在的場(chǎng)所,如液化石油氣。1.0.6細(xì)水霧滅火系統(tǒng)的設(shè)計(jì)、施工及驗(yàn)收除應(yīng)執(zhí)行本規(guī)范規(guī)定外,尚應(yīng)符合現(xiàn)行的有關(guān)國(guó)家標(biāo)準(zhǔn)、規(guī)范的規(guī)定。2術(shù)語(yǔ)、符號(hào)2.1術(shù)語(yǔ)2.1.1細(xì)水霧WaterMist在最小設(shè)計(jì)工作壓力下、距噴頭1.0m處的平面上,測(cè)得水霧的霧滴體積直徑Dv0.99小于1000或Dv0.5小于300,并能夠?qū)馂?zāi)實(shí)施有效撲滅或控制的水霧。2.1.2霧滴體積直徑Dvf霧滴直徑由零到某一直徑的累計(jì)的體積與總體積的比值為f時(shí)的水霧的某一特定直徑。2.1.3細(xì)水霧滅火系統(tǒng)WaterMistFireExtinguishingSystems具有一個(gè)或多個(gè)能夠產(chǎn)生細(xì)水霧的噴頭,并與供水設(shè)備或霧化介質(zhì)相連,可用于控制、抑制及撲滅火災(zāi),能滿足本規(guī)范性能要求的滅火系統(tǒng)。2.1.4低壓系統(tǒng)LowPressureSystems系統(tǒng)的管網(wǎng)工作壓力小于或等于1.21MPa的細(xì)水霧滅火系統(tǒng)。2.1.5中壓系統(tǒng)IntermediatePressureSystems系統(tǒng)的管網(wǎng)工作壓力大于1.21Mpa,小于3.45MPa的細(xì)水霧滅火系統(tǒng)。2.1.6高壓系統(tǒng)HighPressureSystems系統(tǒng)的管網(wǎng)工作壓力大于或等于3.45MPa的細(xì)水霧滅火系統(tǒng)。2.1.7單管系統(tǒng)SinglePipingSystems將水或水和霧化介質(zhì)通過單一管網(wǎng)系統(tǒng)輸送到每個(gè)噴頭的細(xì)水霧滅火系統(tǒng)。2.1.8雙管系統(tǒng)TwinPipingSystem將水和霧化介質(zhì)通過不同的管路,分別輸送到噴頭,并在噴頭內(nèi)部混合而產(chǎn)生細(xì)水霧的滅火系統(tǒng)。2.1.9預(yù)制式系統(tǒng)Pre-engineeredSystem按照保護(hù)空間或保護(hù)對(duì)象預(yù)先確定了系統(tǒng)流量、噴頭壓力、管路長(zhǎng)度等參數(shù)的細(xì)水霧滅火系統(tǒng)。2.1.10全淹沒系統(tǒng)TotalFloodingSystem在規(guī)定的時(shí)間內(nèi),向整個(gè)防護(hù)區(qū)內(nèi)噴射一定量的細(xì)水霧,并使其均勻地充滿整個(gè)防護(hù)區(qū)的滅火系統(tǒng)。2.1.11局部應(yīng)用系統(tǒng)LocalApplicationSystem向被保護(hù)對(duì)象以設(shè)計(jì)噴射流量直接噴射細(xì)水霧,并持續(xù)一定時(shí)間的滅火系統(tǒng)。2.1.12組合分配系統(tǒng)CombinedDistributionSystem用一套細(xì)水霧滅火系統(tǒng)保護(hù)兩個(gè)或兩個(gè)以上防護(hù)區(qū)或保護(hù)對(duì)象的細(xì)水霧滅火系統(tǒng)。2.1.13容器式系統(tǒng)Self-ContainedSupplyingSystem采用儲(chǔ)氣容器給儲(chǔ)水容器進(jìn)行加壓供水的細(xì)水霧滅火系統(tǒng)。2.1.14泵組式系統(tǒng)PumpSupplyingSystem采用泵組進(jìn)行加壓供水的細(xì)水霧滅火系統(tǒng)。2.1.15開式系統(tǒng)OpenSystem采用開式細(xì)水霧噴頭的細(xì)水霧滅火系統(tǒng)。2.1.16閉式系統(tǒng)CloseSystem采用閉式細(xì)水霧噴頭的細(xì)水霧滅火系統(tǒng)。2.1.17作用面積閉式細(xì)水霧滅火系統(tǒng)一次火災(zāi)噴霧保護(hù)的最大面積。2.1.18細(xì)水霧噴頭WaterMistNozzle含有一個(gè)或多個(gè)噴嘴,能夠?qū)⒁欢▔毫Φ乃约?xì)水霧形式噴出的裝置。2.1.19霧化介質(zhì)AtomizingMedia以一定壓力與水進(jìn)行機(jī)械混合而產(chǎn)生細(xì)水霧的惰性氣體。2.1.20防護(hù)區(qū)Protectedarea滿足全淹沒細(xì)水霧滅火系統(tǒng)應(yīng)用條件,并被其保護(hù)的封閉空間。2.1.21系統(tǒng)響應(yīng)時(shí)間ResponseTime,從火災(zāi)自動(dòng)報(bào)警聯(lián)動(dòng)系統(tǒng)發(fā)出滅火信號(hào)起至系統(tǒng)中最不利點(diǎn)噴頭噴出細(xì)水霧的時(shí)間。2.1.22檢驗(yàn)批inspectionlot按同一的生產(chǎn)條件或按規(guī)定的方式匯總起來供檢驗(yàn)用的、由一定數(shù)量樣本組成的檢驗(yàn)體。2.2符號(hào)表2.2編號(hào)符號(hào)單位涵義2.2.1K細(xì)水霧噴頭的特性系數(shù)2.2.2PMPa細(xì)水霧噴頭的工作壓力2.2.3qL/min細(xì)水霧噴頭的流量2.2.4DV0.5μ細(xì)水霧霧滴體積中間直徑范圍2.2.5QL/min細(xì)水霧噴頭的流量2.2.6N只細(xì)水霧噴嘴的實(shí)際應(yīng)用數(shù)量2.2.7P0MPa儲(chǔ)氣容器的工作壓力或泵組的工作壓力2.2.8WL細(xì)水霧滅火系統(tǒng)的設(shè)計(jì)用水量2.2.9WCL系統(tǒng)的儲(chǔ)水量2.2.10d0mm管道外徑2.2.11dimm管道內(nèi)徑2.2.14Smm管道壁厚2.2.15TS累積噴霧時(shí)間2.2.16QjL/min系統(tǒng)流量2.2.17β%允許開口面積系數(shù)3設(shè)計(jì)方法3.1一般規(guī)定3.1.1細(xì)水霧滅火系統(tǒng)的水質(zhì)應(yīng)符合國(guó)家飲用水水質(zhì)標(biāo)準(zhǔn),對(duì)于有特殊要求的被保護(hù)對(duì)象及容器式滅火系統(tǒng)除外。有特殊要求的被保護(hù)對(duì)象:例如,不能有普通水浸潤(rùn)的被保護(hù)對(duì)象、經(jīng)普通水浸潤(rùn)后會(huì)發(fā)生導(dǎo)電、短路等現(xiàn)象而造成重大損失的被保護(hù)場(chǎng)所。這類場(chǎng)所可采用蒸餾水或純凈水作為滅火介質(zhì)。容器式滅火系統(tǒng)的滅火用水一般封閉儲(chǔ)存,長(zhǎng)時(shí)間存放普通水會(huì)對(duì)容器產(chǎn)生腐蝕,因此建議采用蒸餾水或純凈水作為滅火介質(zhì)。3.1.2泵組式細(xì)水霧滅火系統(tǒng)應(yīng)設(shè)置備用泵,備用泵的供水能力應(yīng)不小于最大一臺(tái)工作泵的供水能力。水泵組應(yīng)按一級(jí)負(fù)荷要求供電。當(dāng)保護(hù)對(duì)象中包括泵組系統(tǒng)的電源時(shí),建議設(shè)置UPS備用電源,或采用瓶組式滅火系統(tǒng)。3.1.33.1.4并應(yīng)切斷非消防電源。3.1.5細(xì)水霧實(shí)施滅火前,必須切斷防護(hù)區(qū)內(nèi)的可燃、助燃?xì)怏w氣源。3.1.6采用全淹沒細(xì)水霧滅火系統(tǒng)的防護(hù)區(qū),應(yīng)符合下列規(guī)定:3.1.6.1防護(hù)區(qū)允許開口面積系數(shù)β(開口面積之和與屋頂及四壁面積之和的比值)不宜大于0.2%口面積不應(yīng)大于1.0m250%10%上述要求,應(yīng)對(duì)開口部位設(shè)置細(xì)水霧噴頭進(jìn)行局部加強(qiáng)保護(hù)。3.1.6.2防護(hù)區(qū)的圍護(hù)結(jié)構(gòu)及門、窗的耐火極限不應(yīng)低于0.50h,吊頂?shù)哪突饦O限不應(yīng)低于0.25h。3.1.7采用局部應(yīng)用細(xì)水霧滅火系統(tǒng)的大空間周圍環(huán)境應(yīng)符合下列規(guī)定:3.1.7.1被保護(hù)對(duì)象周圍的空氣流動(dòng)速度不宜大于3.0m/s。3.1.7.2在噴頭與被保護(hù)對(duì)象之間噴頭保護(hù)范圍內(nèi)不應(yīng)有遮擋物。3.1.8采用細(xì)水霧組合分配滅火系統(tǒng),應(yīng)符合下列規(guī)定:3.1.8.1細(xì)水霧組合分配滅火系統(tǒng)的儲(chǔ)水量,不應(yīng)小于最大一個(gè)防護(hù)區(qū)保護(hù)對(duì)象的滅火的用水量。3.1.8.2一套瓶組式細(xì)水霧組合分配滅火系統(tǒng)保護(hù)的防護(hù)區(qū)和保護(hù)對(duì)象數(shù)量不應(yīng)超過88個(gè)時(shí)應(yīng)設(shè)置備用量;重要被保護(hù)對(duì)象應(yīng)設(shè)備用量。備用量不應(yīng)小于設(shè)計(jì)滅火用水量。注:重要被保護(hù)對(duì)象:珍貴檔案資料等。3.1.9細(xì)水霧滅火系統(tǒng)應(yīng)設(shè)置系統(tǒng)動(dòng)作試驗(yàn)裝置,系統(tǒng)動(dòng)作試驗(yàn)裝置應(yīng)設(shè)置在區(qū)域控制閥與水霧噴頭之間,并保證試驗(yàn)時(shí)安全泄水。3.1.10開式細(xì)水霧滅火系統(tǒng)宜應(yīng)用在火災(zāi)危險(xiǎn)程度較大的場(chǎng)所,閉式細(xì)水霧滅火系統(tǒng)宜應(yīng)用在火災(zāi)危險(xiǎn)程度較小的場(chǎng)所。3.1.11細(xì)水霧滅火系統(tǒng)的單個(gè)防護(hù)區(qū)面積不宜超過2000m2,當(dāng)超過時(shí)宜進(jìn)行分區(qū)保護(hù)。3.1.12閉式細(xì)水霧滅火系統(tǒng)的作用面積不宜超過150m2。3.2基本設(shè)計(jì)參數(shù)3.2.1細(xì)水霧滅火系統(tǒng)的基本設(shè)計(jì)參數(shù)應(yīng)根據(jù)細(xì)水霧滅火系統(tǒng)特性、被保護(hù)對(duì)象和防護(hù)區(qū)的具體情況確定。3.2.2細(xì)水霧滅火系統(tǒng)可采用連續(xù)噴霧或間歇噴霧兩種方式,表3.2.2為最小累積噴霧時(shí)間。表3.2.2最小累積噴霧時(shí)間被保護(hù)對(duì)象累積噴霧時(shí)間(min)
室內(nèi)油浸式電力變壓器20
柴油發(fā)電機(jī)、鍋爐房、直燃機(jī)房24
配電室、電纜夾層、電纜隧道計(jì)算機(jī)房、通信機(jī)房30汽輪機(jī)、燃?xì)廨啓C(jī)圖書館、檔案館、博物館3.2.3噴頭3.2.3.1應(yīng)根據(jù)防護(hù)區(qū)高度、面積、火災(zāi)類型、被保護(hù)物體外型及滅火系統(tǒng)類型合理選擇噴頭,同時(shí),必須采用國(guó)家固定滅火系統(tǒng)及耐火構(gòu)件質(zhì)量監(jiān)督檢驗(yàn)中心檢測(cè)合格的產(chǎn)品。噴頭的材質(zhì)宜為不銹鋼。3.2.3.24.0m局部系統(tǒng)噴頭宜均衡布置在被保護(hù)物體周圍,對(duì)于高度超過4.0m的被保護(hù)物體應(yīng)分層布置。3.2.3.3噴頭間距不應(yīng)大于3.0m,并不宜小于2.0m。3.2.3.4最不利點(diǎn)噴頭工作壓力不應(yīng)低于噴頭最低設(shè)計(jì)工作壓力。3.2.3.5噴頭的特性系數(shù)K按生產(chǎn)商提供技術(shù)資料或本規(guī)范附錄A選取。3.2.3.6當(dāng)被保護(hù)對(duì)象為帶電體時(shí),噴頭及管道布置還應(yīng)符合表3.2.3.6要求。表3.2.3.6帶電體額定電壓等級(jí)(kV)噴頭及管道與帶電體外殼之間的距離不應(yīng)小于(m)2202.21101.1350.53.2.4對(duì)于多容器系統(tǒng),同一集流管下所有儲(chǔ)瓶大小和充裝壓力必須一致。3.2.5水量計(jì)算3.2.5.1噴頭的設(shè)計(jì)流量q=K10P(3.2.5.1)式中q-噴頭流量(L/min)P-噴頭壓力(Mpa)K-噴頭流量特性系數(shù)3.2.5.2系統(tǒng)設(shè)計(jì)流量(3.2.5.2)式中Q-系統(tǒng)設(shè)計(jì)流量(L/min)n—系統(tǒng)啟動(dòng)后同時(shí)噴霧的水霧噴頭的數(shù)量;qi—水霧噴頭的實(shí)際流量(L/min),應(yīng)按水霧噴頭的實(shí)際工作壓力Pi(MPa)計(jì)算。3.2.5.3系統(tǒng)設(shè)計(jì)用水量W=Q×T(3.2.5.2)式中W—系統(tǒng)設(shè)計(jì)用水量(L)Q—系統(tǒng)設(shè)計(jì)流量(L/min)T-細(xì)水霧累積噴射時(shí)間(min)3.2.5.4系統(tǒng)儲(chǔ)水量3.2.5.4.1用于撲救B、C類火災(zāi)的容器式細(xì)水霧滅火系統(tǒng)WC=W(3.2.5.4.1)3.2.5.4.2用于撲救A類(表面)火災(zāi)的容器式細(xì)水霧滅火系統(tǒng)WC=1.5W(3.2.5.4.2)3.2.5.4.3泵組式細(xì)水霧滅火系統(tǒng)WC=1.3~1.5W-Qb×T(3.2.5.4.3)Qb—水箱補(bǔ)水流量(L/min)3.2.6細(xì)水霧滅火系統(tǒng)的響應(yīng)時(shí)間不應(yīng)大于30s。3.2.7管網(wǎng)計(jì)算3.2.7.1低壓系統(tǒng)的管道損失應(yīng)按下式計(jì)算――Hazen-Williams公式式中△pm-摩擦損失(bar/m)Q-流量(L/min)di-管道實(shí)際內(nèi)徑(mm)C-管道摩擦損失系數(shù),不銹鋼管或銅管為1503.2.7.2中、高壓系統(tǒng)的管道損失應(yīng)按下式計(jì)算-DarcyWeisbach公式根據(jù)計(jì)算出的Re、ε/di值,查附錄B可得到f值。(3.2.7.2-1)(3.2.7.2-2)式中,見表3.2.7.2,見表3.2.7.2表3.2.7.2不同溫度下水的密度及動(dòng)力粘度溫度(℃)密度ρ(kg/m3)動(dòng)力粘度μ(厘泊cP)0999.81.84.4999.91.510.0999.71.315.6998.81.120.0998.21.026.7996.60.8530.0995.70.8032.2995.40.7437.8993.60.6640.0992.20.6550.0988.10.554系統(tǒng)組件4.1一般規(guī)定4.1.1細(xì)水霧滅火系統(tǒng)成套產(chǎn)品必須采用經(jīng)國(guó)家固定滅火系統(tǒng)及耐火構(gòu)件質(zhì)量監(jiān)督檢驗(yàn)中心檢測(cè)合格的產(chǎn)品。4.1.24.1.3出廠日期等。4.2組件要求4.2.1過濾器過濾器一般安裝在泵組吸水口、儲(chǔ)水容器注水口、噴頭入口或噴頭的每個(gè)噴嘴入口,應(yīng)采用不銹鋼材質(zhì)的過濾網(wǎng)。4.2.1.1過濾器的尺寸應(yīng)能滿足在規(guī)范所規(guī)定的最低響應(yīng)時(shí)間內(nèi),在最低壓力和流量下系統(tǒng)正常工作。4.2.2過濾器濾網(wǎng)的最大網(wǎng)孔不應(yīng)超過噴頭每個(gè)噴嘴通徑的80%。4.2.2噴頭噴頭的選擇應(yīng)考慮下列技術(shù)資料:1適用范圍;2噴頭的流量特性;3保護(hù)空間的最大高度;4噴頭頂端距被保護(hù)物的最大距離;5噴頭之間的最大間距和最小間距;6每個(gè)噴頭的最大保護(hù)面積;7噴頭距墻的最大距離;8噴頭最大和最小工作壓力;4.2.3安全泄壓裝置儲(chǔ)氣容器和儲(chǔ)水容器的設(shè)計(jì)安裝必須遵守生產(chǎn)廠商的技術(shù)要求,每個(gè)壓力容器必須具有安全泄壓裝置。4.2.4控制閥4.2.4.1控制閥的功能應(yīng)符合下列要求:1接通或關(guān)斷細(xì)水霧系統(tǒng)的供水。2接收控制器的信號(hào)實(shí)施啟停控制3具有機(jī)械、電動(dòng)和氣動(dòng)操作方式。4.2.4.2對(duì)于組合分配系統(tǒng),每個(gè)防護(hù)區(qū)或保護(hù)對(duì)象應(yīng)設(shè)一個(gè)區(qū)域控制閥,每個(gè)控制閥上應(yīng)設(shè)有對(duì)應(yīng)防護(hù)區(qū)或保護(hù)對(duì)象的永久性銘牌。4.2.5容器和泵組4.2.5.1細(xì)水霧滅火系統(tǒng)容器、泵組、儲(chǔ)水箱及控制閥應(yīng)設(shè)置在環(huán)境溫度為4~50℃的專用設(shè)備間內(nèi),位置應(yīng)在防護(hù)區(qū)外。對(duì)于容器式細(xì)水霧滅火系統(tǒng),如果設(shè)置在防護(hù)區(qū)外有困難時(shí),可以設(shè)置在防護(hù)區(qū)內(nèi),但應(yīng)用鋼制容器柜加以保護(hù),并在防護(hù)區(qū)外設(shè)置手動(dòng)緊急啟動(dòng)裝置。4.2.5.2專用設(shè)備間的耐火等級(jí)不應(yīng)低于二級(jí),室內(nèi)應(yīng)保持干燥和良好通風(fēng)。設(shè)備間應(yīng)設(shè)置火災(zāi)事故照明裝置,門應(yīng)直通室外或疏散通道。4.2.5.3泵組式系統(tǒng)的儲(chǔ)水箱應(yīng)采用不銹鋼材質(zhì),并應(yīng)采取防塵措施。儲(chǔ)水箱應(yīng)自動(dòng)補(bǔ)水,并應(yīng)在補(bǔ)水管上安裝過濾器。儲(chǔ)水箱還應(yīng)該具有液位顯示、報(bào)警裝置。4.2.5.4泵組式系統(tǒng)應(yīng)該具有測(cè)試水泵工作的條件。4.2.6管道、連接件及支架4.2.6.1系統(tǒng)管道應(yīng)采用不銹鋼無(wú)縫管或銅管,管道規(guī)格及壁厚應(yīng)符合表4.2.6.1-1和表4.2.6.2-2的要求。表4.2.6.1-1不銹鋼無(wú)縫鋼管規(guī)格管外徑(d0)mm管壁厚(s)mm管外徑精確度管壁厚精確度121.5162.0材質(zhì)狀態(tài)標(biāo)準(zhǔn)號(hào)202.5±0.20222.5242.5283.0323.0+12%-10%GB13296-911Cr18Ni9Ti冷拔363.5±0.30404.0485.0±10%銅管管材應(yīng)符合國(guó)家標(biāo)準(zhǔn)GB/T1527-1997,管材壁厚銅管管接頭應(yīng)采用擴(kuò)口式接頭,并應(yīng)符合國(guó)家標(biāo)準(zhǔn)GB/T5625.1-1985。表4.2.6.1-2銅及銅合金拉制管常用規(guī)格(GB/T1527-1997)外徑(mm)壁厚(mm)外徑(mm)壁厚(mm)0.51.551.018230.51.5612021.530.52812232412.5101.52532412121.5283241.52.5162.03032.54注:1.本表摘錄標(biāo)準(zhǔn)中的部分規(guī)格。2..設(shè)計(jì)中根據(jù)系統(tǒng)的壓力不同,分別選取管道的壁厚。高壓系統(tǒng)選上限值,中低壓系統(tǒng)選下限值4.2.6.2系統(tǒng)管道連接件應(yīng)采用與管道同材質(zhì)的管接頭連接。4.2.6.3系統(tǒng)管道應(yīng)采用金屬支、吊架固定,間距應(yīng)符合表4.2.6.3的要求,在距噴頭不超過250mm處應(yīng)設(shè)置支、吊架。支、吊架應(yīng)進(jìn)行防腐處理。表4.2.6.3支、吊架最大間距管道外徑(mm)12162022242832364048最大間距(m)1.71.92.02.22.22.42.52.82.82.84.2.7火災(zāi)自動(dòng)報(bào)警及控制系統(tǒng)細(xì)水霧滅火系統(tǒng)的報(bào)警和控制線路的布線應(yīng)符合現(xiàn)行《火災(zāi)自動(dòng)報(bào)警系統(tǒng)施工及驗(yàn)收規(guī)范》(GB50166)。5操作與控制5.0.1細(xì)水霧滅火系統(tǒng)應(yīng)具有自動(dòng)控制、氣動(dòng)控制和應(yīng)急操作三種控制方式。5.0.2火災(zāi)自動(dòng)報(bào)警及控制系統(tǒng)在自動(dòng)控制下,應(yīng)在接受到兩個(gè)獨(dú)立的火災(zāi)信號(hào)后才能啟動(dòng)細(xì)水霧滅火系統(tǒng)。5.0.3全淹沒滅火系統(tǒng)手動(dòng)操作裝置應(yīng)設(shè)在防護(hù)區(qū)外便于操作的地方,并能在一處完成系統(tǒng)啟動(dòng)的全部操作。局部滅火系統(tǒng)的手動(dòng)操作裝置應(yīng)設(shè)在保護(hù)對(duì)象附近。6安全要求6.0.1防護(hù)區(qū)內(nèi)及入口應(yīng)設(shè)聲光報(bào)警器,報(bào)警時(shí)間不宜小于滅火過程所需時(shí)間,并應(yīng)能手動(dòng)切除報(bào)警信號(hào)。6.0.2防護(hù)區(qū)應(yīng)有能在30s內(nèi)使人員疏散完畢的走道與出口。在疏散走道與出口處,應(yīng)設(shè)火災(zāi)事故照明和疏散指示標(biāo)志。6.0.3防護(hù)區(qū)入口應(yīng)設(shè)噴霧指示燈。6.0.4當(dāng)系統(tǒng)管道設(shè)置在有爆炸危險(xiǎn)的粉塵、可燃?xì)怏w、蒸汽、強(qiáng)電場(chǎng)所時(shí),應(yīng)設(shè)防靜電接地裝置。6.0.5防護(hù)區(qū)的門應(yīng)向疏散方向開啟,在任何情況下均能從防護(hù)區(qū)內(nèi)打開并能自動(dòng)關(guān)閉。7施工、驗(yàn)收7.1基本規(guī)定7.1.1質(zhì)量管理7.1.1.1細(xì)水霧滅火系統(tǒng)施工現(xiàn)場(chǎng)應(yīng)具有健全的質(zhì)量管理體系和工程質(zhì)量檢測(cè)制度,實(shí)現(xiàn)施工全過程質(zhì)量控制。7.1.1.2細(xì)水霧滅火系統(tǒng)應(yīng)按照公安消防機(jī)構(gòu)審核批準(zhǔn)的工程設(shè)計(jì)文件和施工技術(shù)標(biāo)準(zhǔn)進(jìn)行施工,修改設(shè)計(jì)應(yīng)報(bào)原公安消防審核機(jī)構(gòu)審核通過。7.1.1.3細(xì)水霧滅火系統(tǒng)的施工應(yīng)編制施工組織設(shè)計(jì)或施工方案,經(jīng)批準(zhǔn)后方可實(shí)施。7.1.1.4細(xì)水霧滅火系統(tǒng)施工應(yīng)具備下列條件:7.1.1.4.1防護(hù)區(qū)、設(shè)備間設(shè)置條件及防護(hù)區(qū)內(nèi)可燃物的擺放形式與設(shè)計(jì)相符。7.1.1.4.2系統(tǒng)組件及材料齊全,其品種、規(guī)格、型號(hào)符合設(shè)計(jì)要求。7.1.1.4.3系統(tǒng)所需的預(yù)埋件和孔洞符合設(shè)計(jì)要求。7.1.1.4.4具有細(xì)水霧滅火系統(tǒng)水力計(jì)算書,系統(tǒng)及其主要組件的使用、維護(hù)說明書。7.1.1.5細(xì)水霧滅火系統(tǒng)的子分部、分項(xiàng)工程劃分見附錄C。7.1.1.6細(xì)水霧滅火系統(tǒng)應(yīng)進(jìn)行整體驗(yàn)收。7.1.1.7細(xì)水霧滅火系統(tǒng)的施工單位應(yīng)當(dāng)具有相應(yīng)的工程安裝資質(zhì),施工人員應(yīng)具備相應(yīng)的專業(yè)技術(shù)資格。7.1.2材料設(shè)備管理7.1.2.1細(xì)水霧滅火系統(tǒng)及其配套報(bào)警控制產(chǎn)品應(yīng)選用國(guó)家有關(guān)產(chǎn)品質(zhì)量監(jiān)督檢測(cè)單位檢驗(yàn)合格的產(chǎn)品。其它使用的管材配件必須具有質(zhì)量合格證明文件規(guī)格型號(hào)及性能檢測(cè)報(bào)告,應(yīng)符合國(guó)家技術(shù)標(biāo)準(zhǔn)或設(shè)計(jì)要求。進(jìn)場(chǎng)時(shí)應(yīng)做檢查驗(yàn)收并經(jīng)監(jiān)理工程師核查確認(rèn)。7.1.2.2細(xì)水霧滅火系統(tǒng)施工前應(yīng)對(duì)系統(tǒng)組件進(jìn)行外觀檢查,并應(yīng)符合下列規(guī)定:7.1.2.2.1系統(tǒng)組件無(wú)碰撞變形和其它機(jī)械性損傷。7.1.2.2.2組件外露非機(jī)加工表面保護(hù)涂層完好。7.1.2.2.3組件所有外露接口均設(shè)有防護(hù)堵、蓋,且密封良好,接口螺紋無(wú)損傷。7.1.2.2.4銘牌清晰、內(nèi)容完整并符合4.1.3的規(guī)定。7.1.2.2.5噴頭出口宜設(shè)有防塵罩、蓋、涂膠等,并應(yīng)保證不妨礙噴霧。7.1.2.3在系統(tǒng)組件技術(shù)資料中應(yīng)提供控制閥、儲(chǔ)水容器、儲(chǔ)氣容器、集流管合格的水壓強(qiáng)度試驗(yàn)和氣壓嚴(yán)密性試驗(yàn)報(bào)告。如不能出具有效的試驗(yàn)報(bào)告,則應(yīng)在安裝前進(jìn)行水壓強(qiáng)度試驗(yàn)和氣壓嚴(yán)密性試驗(yàn),并應(yīng)符合下列規(guī)定:水壓強(qiáng)度試驗(yàn)的試驗(yàn)壓力為該組件設(shè)計(jì)工作壓力的1.5倍,穩(wěn)壓時(shí)間不少于10min,在穩(wěn)壓期間必須無(wú)壓降。7.1.2.4細(xì)水霧滅火系統(tǒng)安裝前應(yīng)對(duì)控制閥、容器啟動(dòng)閥進(jìn)行檢查。控制閥、容器啟動(dòng)閥上電磁閥的電源電壓及電流應(yīng)符合系統(tǒng)設(shè)計(jì)要求。7.1.2.5儲(chǔ)氣容器內(nèi)氮?dú)鈮毫?yīng)符合產(chǎn)品設(shè)計(jì)要求。7.1.2.6在運(yùn)輸保管和施工過程中應(yīng)采取有效措施防止損壞或腐蝕。7.1.3施工過程質(zhì)量控制7.1.3.1在細(xì)水霧滅火系統(tǒng)的施工安裝過程中應(yīng)做好施工記錄。隱蔽區(qū)域內(nèi)的施工應(yīng)做好隱蔽工程中間驗(yàn)收記錄。7.1.3.2噴頭安裝前,系統(tǒng)的管道應(yīng)嚴(yán)格沖洗和吹掃,避免管道堵塞。7.2施工安裝7.2.1儲(chǔ)水容器、儲(chǔ)氣容器的安裝主控項(xiàng)目:7.2.1.1儲(chǔ)水容器、儲(chǔ)氣容器的正面應(yīng)標(biāo)有與設(shè)計(jì)相符的編號(hào)。7.2.1.2儲(chǔ)水容器、儲(chǔ)氣容器的固定架應(yīng)安裝牢靠,且應(yīng)進(jìn)行防腐處理。一般項(xiàng)目:7.2.1.3儲(chǔ)水容器、儲(chǔ)氣容器的操作面距墻或操作面之間的距離不宜小于1.0m。7.2.2泵組的安裝主控項(xiàng)目:7.2.2.1細(xì)水霧泵組的規(guī)格型號(hào)應(yīng)符合設(shè)計(jì)要求,并應(yīng)有產(chǎn)品檢測(cè)報(bào)告、產(chǎn)品合格證和安裝使用說明書。7.2.2.2泵出口應(yīng)設(shè)置壓力表、控制閥、系統(tǒng)動(dòng)作試驗(yàn)裝置等。7.2.2.3過濾器應(yīng)安裝在水泵吸水管上。一般項(xiàng)目7.2.2.4水泵吸水管水平段上不應(yīng)有氣囊和漏氣現(xiàn)象。7.2.2.5儲(chǔ)水箱應(yīng)采用不銹鋼水箱,應(yīng)設(shè)置防塵裝置、進(jìn)水閥、進(jìn)水過濾器、泄水閥、液位指示及報(bào)警裝置。其有效容積、安裝位置應(yīng)符合設(shè)計(jì)要求。7.2.3區(qū)域控制閥的安裝主控項(xiàng)目7.2.3.1區(qū)域控制閥應(yīng)安裝在操作面一側(cè),安裝高度不宜超過1.7m,不低于1.2m。一般項(xiàng)目7.2.3.2區(qū)域控制閥上應(yīng)設(shè)置標(biāo)明防護(hù)區(qū)名稱或編號(hào)的永久性標(biāo)志牌。7.2.4管道安裝主控項(xiàng)目7.2.4.1細(xì)水霧滅火系統(tǒng)管道采用不銹鋼材質(zhì)或銅質(zhì)的管接頭連接。一般項(xiàng)目7.2.4.2管道穿過墻壁、樓板處應(yīng)安裝套管。穿墻套管長(zhǎng)度應(yīng)和墻厚相等,穿過樓板套管長(zhǎng)度應(yīng)高出地面50mm。管道與套管間的空隙應(yīng)采用柔性不燃材料填塞密實(shí)。7.2.4.3管道支吊架安裝應(yīng)符合下列規(guī)定:7.2.4.3.1管道應(yīng)固定牢靠,支吊架最大間距應(yīng)符合表4.2.6.37.2.4.3.2管道末端處應(yīng)采用支架固定,支架與噴頭間的管道長(zhǎng)度不應(yīng)大于250mm。7.2.5管道試驗(yàn)主控項(xiàng)目7.2.5.1細(xì)水霧滅火系統(tǒng)管道安裝完畢后,應(yīng)進(jìn)行水壓強(qiáng)度試驗(yàn)和氣壓嚴(yán)密性試驗(yàn)。7.2.5.2細(xì)水霧滅火系統(tǒng)管道水壓強(qiáng)度試驗(yàn)壓力應(yīng)為系統(tǒng)設(shè)計(jì)壓力1.510min應(yīng)無(wú)滴漏,在穩(wěn)壓期間必須無(wú)壓降。一般項(xiàng)目7.2.5.3水漬及其它贓物出現(xiàn)。7.2.6噴頭的安裝主控項(xiàng)目7.2.6.1噴頭安裝時(shí)應(yīng)逐個(gè)核對(duì)其型號(hào)、規(guī)格和噴孔方向,并應(yīng)符合設(shè)計(jì)要求。一般項(xiàng)目7.2.6.2噴頭出口宜設(shè)有防塵罩、蓋、涂膠等,并應(yīng)保證不妨礙噴霧。7.3系統(tǒng)調(diào)試7.3.1一般規(guī)定7.3.1.1細(xì)水霧滅火系統(tǒng)的調(diào)試宜在系統(tǒng)安裝完畢,以及有關(guān)的火災(zāi)報(bào)警系統(tǒng)和開口自動(dòng)關(guān)閉裝置、通風(fēng)機(jī)械和防火閥等聯(lián)動(dòng)設(shè)備的調(diào)試完成后進(jìn)行。7.3.1.2細(xì)水霧滅火系統(tǒng)的調(diào)試前應(yīng)具備完整的技術(shù)資料及調(diào)試必須的其它資料,并應(yīng)符合7.1.1.47.1.3.1條的規(guī)定。7.3.1.3細(xì)水霧滅火系統(tǒng)的調(diào)試負(fù)責(zé)人應(yīng)由專業(yè)技術(shù)人員擔(dān)任,參加調(diào)試的人員應(yīng)職責(zé)明確。7.3.1.4細(xì)水霧滅火系統(tǒng)調(diào)試前應(yīng)按7.1和7.2節(jié)的要求檢查系統(tǒng)組件和材料的型號(hào)、規(guī)格、數(shù)量,以及系統(tǒng)安裝質(zhì)量,并應(yīng)及時(shí)處理所發(fā)現(xiàn)的問題。7.3.1.5系統(tǒng)調(diào)試后應(yīng)按附錄F規(guī)定的內(nèi)容提出調(diào)試報(bào)告。7.3.2調(diào)試主控項(xiàng)目7.3.2.1細(xì)水霧滅火系統(tǒng)的調(diào)試,應(yīng)采用系統(tǒng)動(dòng)作試驗(yàn)裝置進(jìn)行模擬系統(tǒng)動(dòng)作試驗(yàn)。7.3.2.2系統(tǒng)動(dòng)作試驗(yàn)的結(jié)果應(yīng)符合下列規(guī)定:(1)系統(tǒng)動(dòng)作試驗(yàn)裝置的流量應(yīng)與系統(tǒng)流量相當(dāng),系統(tǒng)壓力應(yīng)符合設(shè)計(jì)要求。(2)至少對(duì)一個(gè)防護(hù)區(qū)進(jìn)行實(shí)際噴霧試驗(yàn),該防護(hù)區(qū)內(nèi)每個(gè)噴頭均應(yīng)正常噴出細(xì)水霧。(3)有關(guān)閥門工作正常。(4)有關(guān)聲光報(bào)警信號(hào)正確。(5)設(shè)備和管道無(wú)明顯晃動(dòng)和機(jī)械損壞。一般項(xiàng)目7.3.2.3系統(tǒng)動(dòng)作試驗(yàn)宜采用自動(dòng)控制。7.3.2.4系統(tǒng)動(dòng)作試驗(yàn)時(shí)控制閥應(yīng)關(guān)閉。對(duì)于允許噴霧的防護(hù)區(qū)或被保護(hù)對(duì)象,宜打開相應(yīng)的控制閥而關(guān)閉系統(tǒng)動(dòng)作試驗(yàn)裝置進(jìn)行實(shí)際噴霧。7.3.2.5系統(tǒng)動(dòng)作試驗(yàn)宜持續(xù)1min,試驗(yàn)完成后應(yīng)恢復(fù)系統(tǒng),并補(bǔ)充儲(chǔ)氣容器壓力和儲(chǔ)水容器或儲(chǔ)水箱中的水量至設(shè)計(jì)要求值。7.4細(xì)水霧滅火系統(tǒng)工程質(zhì)量驗(yàn)收7.4.1一般規(guī)定7.4.1.1細(xì)水霧滅火系統(tǒng)的質(zhì)量驗(yàn)收應(yīng)由建設(shè)單位組織,設(shè)計(jì)、監(jiān)理、施工及供貨廠商參加共同進(jìn)行。質(zhì)量驗(yàn)收均應(yīng)在施工單位自檢合格的基礎(chǔ)上進(jìn)行并應(yīng)按檢驗(yàn)批、分項(xiàng)分部(或子分部)、單位(或子單位)工程的程序進(jìn)行驗(yàn)收同時(shí)做好記錄。7.4.1.1.1檢驗(yàn)批、分項(xiàng)工程的質(zhì)量驗(yàn)收應(yīng)全部合格a.檢驗(yàn)批質(zhì)量驗(yàn)收見附錄Db.分項(xiàng)工程質(zhì)量驗(yàn)收見附錄E7.4.1.1.2子分部工程的驗(yàn)收必須在分項(xiàng)工程驗(yàn)收通過的基礎(chǔ)上對(duì)重要部位進(jìn)行抽樣檢驗(yàn)和檢測(cè)。細(xì)水霧滅火系統(tǒng)(子分部)工程質(zhì)量驗(yàn)收見附錄F7.4.1.1.3對(duì)于重點(diǎn)工程的細(xì)水霧滅火系統(tǒng)宜選擇某一防護(hù)空間進(jìn)行系統(tǒng)的冷噴試驗(yàn)。7.4.1.2公安消防機(jī)構(gòu)應(yīng)在以上四方質(zhì)量驗(yàn)收合格的基礎(chǔ)上進(jìn)行抽樣性消防驗(yàn)收。7.4.2質(zhì)量驗(yàn)收的內(nèi)容:7.4.2.1儲(chǔ)水容器、儲(chǔ)氣容器的設(shè)置是否符合設(shè)計(jì)要求;7.4.2.2泵組及系統(tǒng)組件的設(shè)置是否符合設(shè)計(jì)要求;7.4.2.3控制閥的安裝是否正確;7.4.2.4系統(tǒng)管道的選材、連接及敷設(shè)是否滿足功能要求;7.4.2.5系統(tǒng)管道沖洗及測(cè)試;7.4.2.6系統(tǒng)管道的水壓強(qiáng)度試驗(yàn)及氣密性試驗(yàn);7.4.2.7噴頭的數(shù)量、規(guī)格及安裝位置是否符合設(shè)計(jì)要求;7.4.2.8細(xì)水霧滅火系統(tǒng)各種啟動(dòng)方式的測(cè)試是否合格。7.4.3工程質(zhì)量驗(yàn)收文件和記錄中應(yīng)包括下列主要內(nèi)容:7.4.3.1經(jīng)批準(zhǔn)的竣工驗(yàn)收申請(qǐng)報(bào)告。7.4.3.2施工記錄和隱蔽工程中間驗(yàn)收記錄。7.4.3.3竣工圖和設(shè)計(jì)變更文字記錄。7.4.3.4竣工報(bào)告。7.4.3.5設(shè)計(jì)說明書。7.4.3.6調(diào)試報(bào)告。7.4.3.7系統(tǒng)及其主要組件的使用維護(hù)說明書。7.4.3.8系統(tǒng)組件、管道及管道連接件的檢驗(yàn)報(bào)告、試驗(yàn)報(bào)告和出廠合格證。附錄A噴頭選型表噴頭編號(hào)1#2#3#4#細(xì)水霧噴頭的特性系數(shù)K0.50.71.2≥1.7細(xì)水霧霧滴體積中間直徑范DV0.520~300μ微型噴嘴霧化角度400/800適用空間高度≤5.0m木材√√A類紙張√√√√適用火災(zāi)類型煙草√√√B類√√√√電氣√√√√附錄B雷諾曲線.管道摩擦系數(shù)f附錄C細(xì)水霧滅火系統(tǒng)的子分部和分項(xiàng)工程可按附表C劃分細(xì)水霧滅火系統(tǒng)子分部、分項(xiàng)工程劃分表子分部工程序號(hào)分項(xiàng)工程1噴頭的安裝2儲(chǔ)水容器、儲(chǔ)氣容器的安裝3泵組的安裝細(xì)水霧滅火系統(tǒng)4區(qū)域控制閥的安裝5管道安裝6管道試驗(yàn)7系統(tǒng)調(diào)試附錄D檢驗(yàn)批質(zhì)量驗(yàn)收檢驗(yàn)批質(zhì)量驗(yàn)收表由施工單位項(xiàng)目專業(yè)質(zhì)量檢查員填寫,監(jiān)理工程師(建設(shè)單位項(xiàng)目專業(yè)技術(shù)負(fù)責(zé)人)組織施工單位項(xiàng)目質(zhì)量(技術(shù))負(fù)責(zé)人等進(jìn)行驗(yàn)收,并按附表D填寫驗(yàn)收結(jié)論。附表D檢驗(yàn)批質(zhì)量驗(yàn)收表工程名稱專業(yè)工長(zhǎng)/證號(hào)分部工程名稱施工班、組長(zhǎng)施工單位驗(yàn)收部位施標(biāo)準(zhǔn)名稱材料/數(shù)量/工依編號(hào)/據(jù)存放處《規(guī)范》章、節(jié)、條、款號(hào)質(zhì)量規(guī)定施工單位檢查評(píng)定結(jié)果監(jiān)理(建設(shè))單位驗(yàn)收主控項(xiàng)目一般項(xiàng)目項(xiàng)目專業(yè)質(zhì)量檢查員:項(xiàng)目專業(yè)質(zhì)量(技術(shù))負(fù)責(zé)人:
施工單位檢查評(píng)定結(jié)果年月日收結(jié)論監(jiān)理工程師:(建設(shè)單位項(xiàng)目專業(yè)技術(shù)負(fù)責(zé)人)年月日附錄E分項(xiàng)工程質(zhì)量驗(yàn)收分項(xiàng)工程質(zhì)量驗(yàn)收由監(jiān)理工程師(建設(shè)單位項(xiàng)目專業(yè)技術(shù)負(fù)責(zé)人)組織施工單位項(xiàng)目專業(yè)質(zhì)量(技術(shù))負(fù)責(zé)人等進(jìn)行驗(yàn)收,并按附表E填寫附表E_______分項(xiàng)工程質(zhì)量驗(yàn)收表工程名稱分項(xiàng)工程名稱項(xiàng)目技術(shù)負(fù)責(zé)人/證號(hào)項(xiàng)目質(zhì)檢員/證號(hào)專業(yè)工長(zhǎng)/證號(hào)序號(hào)檢驗(yàn)批部位/數(shù)量施工單位檢查評(píng)定結(jié)果監(jiān)理(建設(shè))單位驗(yàn)收結(jié)論檢驗(yàn)查結(jié)項(xiàng)目專業(yè)質(zhì)量(技術(shù))負(fù)責(zé)人:收結(jié)監(jiān)理工程師:論論(建設(shè)單位項(xiàng)目專業(yè)技術(shù)負(fù)責(zé)人)年月日
年月日附錄F細(xì)水霧滅火系統(tǒng)(子分部)工程質(zhì)量驗(yàn)收專業(yè)項(xiàng)目負(fù)責(zé)人、設(shè)計(jì)單位項(xiàng)目負(fù)責(zé)人進(jìn)行驗(yàn)收,并按附錄F填表附表F細(xì)水霧滅火系統(tǒng)(子分部)工程質(zhì)量驗(yàn)收表工程名稱設(shè)置部位施工單位開/竣工日期項(xiàng)目經(jīng)理/證號(hào)專業(yè)技術(shù)負(fù)責(zé)人/證號(hào)項(xiàng)目專業(yè)技術(shù)負(fù)責(zé)人/證號(hào)序號(hào)項(xiàng)目驗(yàn)收內(nèi)容驗(yàn)收結(jié)論分項(xiàng)工程質(zhì)量驗(yàn)收范及設(shè)計(jì)要求__分項(xiàng)質(zhì)量管理資料檢查經(jīng)核定符合規(guī)范要求__項(xiàng)功能核查抽查結(jié)果共抽查__項(xiàng),符合要求__項(xiàng);經(jīng)返工處理符合要求__項(xiàng)觀感質(zhì)量驗(yàn)收共抽查__項(xiàng),符合要求__項(xiàng);不符合要求__項(xiàng)綜合驗(yàn)收結(jié)論施工單位設(shè)計(jì)單位監(jiān)理單位建設(shè)單位參加驗(yàn)收單位(公章)(公章)(公章)(公章)單位(項(xiàng)目)單位(項(xiàng)目)總監(jiān)理工程師單位(項(xiàng)目)負(fù)責(zé)人:負(fù)責(zé)人::負(fù)責(zé)人:年月日年月日年月日年月日附錄G本規(guī)范用詞說明A.0.1為便于在執(zhí)行本規(guī)范條文時(shí)區(qū)別對(duì)待,對(duì)要求嚴(yán)格程度不同的用詞說明如下:A.0.1.1表示很嚴(yán)格,非這樣做不可的用詞:正面詞采用“必須;反面詞采用“嚴(yán)禁。A.0.1.2表示嚴(yán)格,在正常情況下均應(yīng)這樣做的用詞:正面詞采用“應(yīng);反面詞采用“不應(yīng)”或“不得。A.0.1.3表示允許稍有選擇,在條件許可時(shí)首先應(yīng)這樣做的用詞:正面詞采用“宜”或“可;反面詞采用“不宜。A.0.2條文中指明應(yīng)按其他有關(guān)標(biāo)準(zhǔn)、規(guī)范執(zhí)行時(shí),寫法為“應(yīng)符號(hào)……的規(guī)定”或“應(yīng)按……執(zhí)行。目次1總則...............................................................................212術(shù)語(yǔ)、符號(hào).........................................................................222.1術(shù)語(yǔ)............................................................................222.2符號(hào)(略)3系統(tǒng)設(shè)計(jì)...........................................................................233.1一般規(guī)定.........................................................................233.2基本設(shè)計(jì)參數(shù).....................................................................244系統(tǒng)組件...........................................................................264.1一般規(guī)定.4.2組件要求.........................................................................265操作與控制.........................................................................276安全要求...........................................................................277施工與驗(yàn)收.........................................................................287.1基本規(guī)定.........................................................................287.2施工安裝.................................................................297.3系統(tǒng)調(diào)試.........................................................................307.4細(xì)水霧滅火系統(tǒng)工程質(zhì)量驗(yàn)收..........................................................311總則1.0.1本條提出了制定本規(guī)范的目的和意義,即合理地設(shè)計(jì)細(xì)水霧滅火系統(tǒng)通過正確的施工與調(diào)試方式,使之有效地保護(hù)人身和財(cái)產(chǎn)安全。細(xì)水霧滅火系統(tǒng)是以水為介質(zhì),采用特殊噴頭在特定的工作壓力下噴灑細(xì)水霧進(jìn)行滅火或控火的一種固定式滅火系統(tǒng)。細(xì)水霧霧滴直徑小,比表面積大,火場(chǎng)火焰及高溫將其迅速汽化,細(xì)水霧在汽化過程中吸收大量熱量,降低火場(chǎng)溫度,并降低氧氣含量,達(dá)到迅速滅火的功效。細(xì)水霧滅火系統(tǒng)的研究及應(yīng)用的歷史超過50年,但其技術(shù)發(fā)展也長(zhǎng)期處于停滯不前狀態(tài)。隨著近幾年科學(xué)技術(shù)的高速發(fā)展,加之鹵代烷系列滅火劑的全面被禁止使用,大量消防保護(hù)場(chǎng)所亟待新型的滅火系統(tǒng)予以保護(hù)。在各國(guó)科研、生產(chǎn)及學(xué)術(shù)研究機(jī)構(gòu)的共同努力下細(xì)水霧滅火技術(shù)有了較大的發(fā)展。細(xì)水霧滅火系統(tǒng)對(duì)保護(hù)對(duì)象可實(shí)施滅火、抑制火、控制火、控溫和降塵等多種方式的保護(hù),同時(shí),對(duì)于撲救帶電設(shè)備火災(zāi)中發(fā)揮了良好的作用。其滅火機(jī)理可歸納如下:1、高效吸熱細(xì)水霧噴頭對(duì)具有一定壓力的水流進(jìn)行分流、撞擊以及空氣霧化,將噴頭出口處?kù)F滴粒徑控制在1000μ100℃水的蒸發(fā)潛熱為2257kJ/kg計(jì),每只噴嘴噴出的水霧吸熱功率約為300kW。2、窒息細(xì)水霧噴入火場(chǎng)后,霧滴在受熱汽化后,體積增大了1700倍,最大限度地排除了火場(chǎng)的空氣,在燃燒物周圍形成一道屏障阻擋新鮮空氣的吸入。當(dāng)氧氣周圍的氧氣濃度降低到一定水平時(shí),火焰將被窒息、熄滅。3、阻隔輻射熱細(xì)水霧噴入火場(chǎng)后,蒸發(fā)形成的蒸汽迅速將燃燒物、火焰和煙羽籠罩,對(duì)火焰的輻射熱具有極佳的阻隔能力,能夠有效抑制輻射熱引燃周圍其它物品,達(dá)到防止火焰蔓延的效果。我國(guó)的細(xì)水霧滅火系統(tǒng)研究以公安部天津消防科學(xué)研究所承擔(dān)的國(guó)家“九五重點(diǎn)科技攻關(guān)項(xiàng)目子專題“細(xì)水霧滅火系統(tǒng)的研究課題為代表。該項(xiàng)目已于2001年12月通過了科技部和公安部組織的項(xiàng)目鑒定。該項(xiàng)目提出的高壓細(xì)水霧滅火系統(tǒng)滅火機(jī)理、適用范圍、工程應(yīng)用技術(shù)參數(shù)等數(shù)據(jù)和結(jié)論是編制本規(guī)范的重要基礎(chǔ)和依據(jù)。為了盡快將細(xì)水霧滅火系統(tǒng)這項(xiàng)新技術(shù)應(yīng)用到工程實(shí)際中,公安部天津消防科學(xué)研究所于2002年先后主持召開了“室內(nèi)油浸式電力變壓器細(xì)水霧滅火系統(tǒng)工程應(yīng)用性實(shí)體滅火實(shí)驗(yàn)和“圖書、檔案庫(kù)房細(xì)水霧滅火系統(tǒng)工程應(yīng)用性實(shí)體滅火實(shí)驗(yàn)”專家評(píng)定會(huì),兩次會(huì)議得出了關(guān)于A類、B類火災(zāi)的工程應(yīng)用技術(shù)參數(shù)和結(jié)論,為編制本規(guī)范進(jìn)一步提供了依據(jù)。美國(guó)防火協(xié)會(huì)于1996年第一次發(fā)布了《細(xì)水霧滅火系統(tǒng)標(biāo)準(zhǔn)》NFPA750,后經(jīng)修訂,又發(fā)布了2000版的《細(xì)NFPA750NFPA750闡述和界定。由于我國(guó)目前尚無(wú)相關(guān)的技術(shù)標(biāo)準(zhǔn),為了規(guī)范細(xì)水霧滅火系統(tǒng)的設(shè)計(jì)及施工過程,為了提供必要的消防審核、1.0.2本規(guī)范目前不適用于運(yùn)輸工具中設(shè)置的細(xì)水霧滅火系統(tǒng)的設(shè)計(jì)。1.0.3本條規(guī)定了細(xì)水霧滅火系統(tǒng)設(shè)計(jì)、施工及產(chǎn)品選型的原則。考慮到細(xì)水霧滅火系統(tǒng)本身就屬于不斷發(fā)展完善的新型滅火系統(tǒng),需要不斷地引進(jìn)和開發(fā)新的技術(shù),將成熟、先進(jìn)的相關(guān)產(chǎn)品運(yùn)用到滅火系統(tǒng)中來。但同時(shí)也要求在保障安全可行并且經(jīng)濟(jì)合理的前提下使用新技術(shù)、新產(chǎn)品。1.0.4本條規(guī)定的細(xì)水霧滅火系統(tǒng)適用范圍是在多次火災(zāi)模擬實(shí)驗(yàn)以及大量經(jīng)證實(shí)安全可靠的國(guó)內(nèi)外技術(shù)資料的基礎(chǔ)上列出的。本規(guī)范將細(xì)水霧滅火系統(tǒng)的適用范圍限定在室內(nèi)及地下建筑物內(nèi)環(huán)境正是由于規(guī)范組目前所掌握的相關(guān)技術(shù)資料和試驗(yàn)數(shù)據(jù)還不足以證明細(xì)水霧滅火系統(tǒng)能夠撲滅廣東地區(qū)任何氣候條件下的相關(guān)類型火災(zāi)。因此,在本規(guī)范適用范圍中沒有包括室外場(chǎng)所的內(nèi)容。1.0.5本條主要是明確了不能以水介質(zhì)撲救的火災(zāi)類型。1.0.6本條規(guī)定中所指的“現(xiàn)行的國(guó)家有關(guān)標(biāo)準(zhǔn),除在本規(guī)范中已指明的以外,還包括以下幾個(gè)方面的標(biāo)準(zhǔn):1、防火基礎(chǔ)標(biāo)準(zhǔn)與有關(guān)的安全基礎(chǔ)標(biāo)準(zhǔn);2、有關(guān)的工業(yè)與民用建筑防火標(biāo)準(zhǔn)、規(guī)范;3、有關(guān)的火災(zāi)自動(dòng)報(bào)警系統(tǒng)標(biāo)準(zhǔn)、規(guī)范;4、有關(guān)的產(chǎn)品標(biāo)準(zhǔn);5、其它有關(guān)的標(biāo)準(zhǔn)。2術(shù)語(yǔ)、符號(hào)2.1術(shù)語(yǔ)2.1.1細(xì)水霧WaterMist本條定義是參照NFPA-750關(guān)于細(xì)水霧的定義,但在水霧霧滴大小的選擇上又略有不同。通常,水霧粒子粒徑若Dv0.99小于400,則基本上可以撲滅B類火災(zāi)。較大粒徑的水霧粒子由于對(duì)燃燒物有較佳的濕潤(rùn)效果,因此對(duì)撲滅A類火災(zāi)十分有效。由于以上原因,本規(guī)定定義細(xì)水霧系統(tǒng)為能產(chǎn)生Dv0.99小于1000的水霧系統(tǒng)。2.1.2霧滴體積直徑Dvf霧滴體積中間直徑Dv0.5,表示噴霧液體總體積中50%50%是由直徑小于此中間直徑的液滴組成的。也就是說,在該直徑以上或以下的粒子的累積體積相等。Dv0.5也可表示為VMD,是一種以被噴霧液體的體積來表示液滴大小的方法。由于VMD是以噴霧液體體積為基礎(chǔ)的表示方法,所以它被廣泛引用。2.1.3細(xì)水霧滅火系統(tǒng)WaterMistSystems2.1.4低壓系統(tǒng)LowPressureSystems根據(jù)NFPA-750的定義,系統(tǒng)工作壓力小于175psi(12.1bar)為低壓細(xì)水霧滅火系統(tǒng)。2.1.5中壓系統(tǒng)IntermediatePressureSystems根據(jù)NFPA-750的定義,系統(tǒng)工作壓力大于175psi(12bar),小于500psi(34.5bar)為中壓細(xì)水霧滅火系統(tǒng)。2.1.6高壓系統(tǒng)HighPressureSystems根據(jù)NFPA-750中定義,系統(tǒng)工作壓力大于500psi(34.5bar)為高壓細(xì)水霧滅火系統(tǒng)。公安部天津消防研究所在進(jìn)行細(xì)水霧實(shí)體滅火試驗(yàn)過程中特別側(cè)重研究和試驗(yàn)了細(xì)水霧高、中、低壓滅火系統(tǒng)對(duì)各類火災(zāi)的滅火效果。高壓細(xì)水霧滅火系統(tǒng)適應(yīng)范圍最為廣泛,它能撲滅:A類、B類、C類火災(zāi)和電器火災(zāi)。如:電子計(jì)算機(jī)房、通信設(shè)備房、控制室、磁帶庫(kù)、配電間、檔案庫(kù)、油浸變壓器室、液壓設(shè)備室、地鐵車站等場(chǎng)所的消防保護(hù),這些類型的保護(hù)區(qū)在國(guó)外已有很多采用高壓系統(tǒng)保護(hù)的工程實(shí)例。中、低壓系統(tǒng)較多用于B類火災(zāi)。2.1.7單管系統(tǒng)SinglePipingSystems對(duì)于只有水一種液體在管道內(nèi)流動(dòng),稱為單流體系統(tǒng),應(yīng)該沒有疑問;如果還有一種系統(tǒng),管路內(nèi)流動(dòng)的有高壓氮和水,盡管是氣、液兩相流,按照本規(guī)范的定義,也應(yīng)該是單流體細(xì)水霧滅火系統(tǒng)。2.1.8雙管系統(tǒng)TwinPipingSystem雙管系統(tǒng)產(chǎn)生細(xì)水霧的機(jī)理是,低速流動(dòng)的水流與較高速度流動(dòng)的氣流相接觸,產(chǎn)生水霧霧滴。雙流體系統(tǒng)的霧化噴頭如圖所示。氣體入口水入口霧化噴頭2.1.9預(yù)制式系統(tǒng)Pre-engineeredSystem某一種規(guī)格或類型的預(yù)制式系統(tǒng)可以保護(hù)的火災(zāi)種類及保護(hù)空間的規(guī)模,都要由實(shí)驗(yàn)室根據(jù)實(shí)際火災(zāi)試驗(yàn)來測(cè)定。進(jìn)口的細(xì)水霧滅火系統(tǒng)多數(shù)都通過了FMFMRC提供的實(shí)驗(yàn)報(bào)告。對(duì)于預(yù)制系統(tǒng),廠商提供的設(shè)計(jì)手冊(cè)包括了工程設(shè)計(jì)所需要的基本參數(shù),設(shè)計(jì)師只需要簡(jiǎn)單計(jì)算就可選出適當(dāng)?shù)南到y(tǒng)。該系統(tǒng)是應(yīng)用最為廣泛、最為成熟的一種細(xì)水霧滅火系統(tǒng)2.1.10全淹沒系統(tǒng)TotalFloodingSystem主要用于保護(hù)整個(gè)防護(hù)區(qū),而不同于局部應(yīng)用系統(tǒng),只保護(hù)一個(gè)具特定的設(shè)備或設(shè)備的某一部分。2.1.11局部應(yīng)用系統(tǒng)LocalApplicationSystem主要是保護(hù)一個(gè)特定的被保護(hù)對(duì)象,或該對(duì)象的一個(gè)局部,如燃?xì)廨啓C(jī)的軸承。細(xì)水霧相對(duì)于氣體滅火系統(tǒng)的重要優(yōu)勢(shì)之一,就是被保護(hù)空間封閉程度對(duì)滅火效果的影響要比氣體小的多,所以可以采用局部應(yīng)用系統(tǒng)。2.1.12組合分配系統(tǒng)CombinedDistributionSystem考慮到在一棟建筑內(nèi)同一時(shí)間發(fā)生火災(zāi)的概率只有一次,因此,在建筑物內(nèi)設(shè)有兩個(gè)或兩個(gè)以上防護(hù)區(qū)時(shí)就可以采用一套細(xì)水霧滅火系統(tǒng)進(jìn)行保護(hù)。2.1.13容器式系統(tǒng)Self-ContainedSupplyingSystem由儲(chǔ)水容器、儲(chǔ)氣容器、單向閥、集流管、安全泄壓裝置、控制閥、噴嘴、管道、連接管件及壓力開關(guān)、探測(cè)器、報(bào)警控制器等部件組成的細(xì)水霧滅火系統(tǒng)。該系統(tǒng)備用狀態(tài)下儲(chǔ)水容器常壓、儲(chǔ)氣容器高壓。2.1.14泵組式系統(tǒng)PumpSupplyingSystem報(bào)警控制器等部件組成的細(xì)水霧滅火系統(tǒng)。該系統(tǒng)備用狀態(tài)下儲(chǔ)水箱存儲(chǔ)滅火所需全部水量。2.1.18細(xì)水霧噴頭WaterMistNozzle它是系統(tǒng)中最為關(guān)鍵的部件。根據(jù)噴嘴的結(jié)構(gòu)形式、噴霧形狀分及用途分為許多種類型,用于消防系統(tǒng)的噴嘴主要有螺旋式噴嘴(spiralnozzleair-atomizingnozzleImpingingnozzle多頭噴嘴(clusternozzles)、多孔噴嘴(multipleorificenozzle)等。噴嘴產(chǎn)生細(xì)水霧的原理為下列幾種方式之一:液體以相對(duì)于周圍空氣很高的速度被釋放出來,由于液體與空氣的速度差而被撕碎成在液滴直徑在幾百微米的水細(xì)水霧;液體流碰到固定的表面,因碰撞產(chǎn)生水微粒子;兩股組成類似的流體相互碰撞,形成水微粒子。描述噴嘴水力特性的參數(shù)主要有,水霧液滴直徑,噴嘴接口的螺紋尺寸、特性系數(shù)(K)、在各個(gè)壓力下的流量、噴霧角度、噴嘴孔徑、自由暢通直徑。自由暢通直徑(FreePassDiameter)是指該尺寸的顆粒通過噴頭時(shí)不至于堵塞。此外還有噴頭的外形尺寸、重量、制造材料、消防認(rèn)證等。2.1.19霧化介質(zhì)AtomizingMedia作為霧化介質(zhì)的氣體,既可以是有高壓氮?dú)猓部梢允菈嚎s空氣。2.1.20防護(hù)區(qū)Protectedarea防護(hù)區(qū)必須具有一定的承壓能力,保持相應(yīng)封閉性。其圍護(hù)結(jié)構(gòu)應(yīng)具有一定的耐火等級(jí)。2.1.21系統(tǒng)響應(yīng)時(shí)間ResponseTime系統(tǒng)響應(yīng)時(shí)間對(duì)有效撲救初起火災(zāi)具有重要意義。2.1.22檢驗(yàn)批inspectionlot根據(jù)《建筑工程質(zhì)量驗(yàn)收統(tǒng)一標(biāo)準(zhǔn)》,工程竣工驗(yàn)收所包括的最基本內(nèi)容,在驗(yàn)收工作中的最小單位。3設(shè)計(jì)方法3.1.1由于細(xì)水霧噴頭的孔徑一般非常小,水中的雜質(zhì)會(huì)影響細(xì)水霧滅火系統(tǒng)組件的正常工作,因此對(duì)該系統(tǒng)用水的水質(zhì)提出要求。對(duì)于特殊的被保護(hù)物體為達(dá)到更好的滅火效果也可以在水中加入適當(dāng)?shù)臏缁鹚巹K|(zhì)應(yīng)為無(wú)污染、無(wú)腐蝕、無(wú)懸浮物、無(wú)沉淀物。其最低要求應(yīng)達(dá)到國(guó)家飲用水水質(zhì)標(biāo)準(zhǔn),有特殊要求的被保護(hù)對(duì)象所需水質(zhì)由設(shè)計(jì)者定。3.1.2設(shè)置備用泵是為了保證系統(tǒng)供水的可靠性,備用泵的流量和揚(yáng)程應(yīng)不小于最大一臺(tái)工作泵的流量和揚(yáng)程。可靠的動(dòng)力保障,也是保證可靠供水的重要措施。因此,提出了泵組式滅火系統(tǒng)的供電負(fù)荷必須達(dá)到一級(jí)負(fù)荷。這條規(guī)定與現(xiàn)行國(guó)家防火規(guī)范要求相同。3.1.3全淹沒滅火系統(tǒng)是對(duì)整個(gè)保護(hù)空間進(jìn)行滅火,設(shè)計(jì)滅火系統(tǒng)時(shí)必須以整個(gè)保護(hù)空間的體積為依據(jù)進(jìn)行設(shè)計(jì)計(jì)算;局部滅火系統(tǒng)是指細(xì)水霧完全分布到被保護(hù)的危險(xiǎn)區(qū)域或物品的周圍,局部應(yīng)用系統(tǒng)必須設(shè)計(jì)成能保護(hù)在封閉、半封閉或戶外條件下的物品或危險(xiǎn)區(qū)域,局部應(yīng)用系統(tǒng)必須采用自動(dòng)噴頭或通過獨(dú)立的探測(cè)系統(tǒng)來驅(qū)動(dòng)。3.1.4由于細(xì)水霧具有趨熱特性,而且水顆粒細(xì)小、質(zhì)量輕,所以細(xì)水霧系統(tǒng)釋放滅火前,應(yīng)關(guān)閉影響滅火效果的設(shè)備和設(shè)施。對(duì)于人員確認(rèn)發(fā)生的火災(zāi)已經(jīng)被撲滅后,才可啟動(dòng)排煙設(shè)備進(jìn)行排煙和災(zāi)后處理。3.1.5細(xì)水霧滅火系統(tǒng)對(duì)于A、B類火災(zāi)非常有效,但對(duì)于撲滅可燃?xì)怏w的火災(zāi),必須在細(xì)水霧滅火系統(tǒng)中設(shè)置聯(lián)動(dòng)信號(hào),滅火系統(tǒng)釋放前,關(guān)斷可燃?xì)怏w氣源。3.1.6本條嚴(yán)格限定了對(duì)全淹沒滅火系統(tǒng)的要求,必須嚴(yán)格分析保護(hù)區(qū)域的特點(diǎn),精密設(shè)計(jì),使系統(tǒng)安全有效。3.1.6.13.1.6.2同等采用《二氧化碳滅火系統(tǒng)設(shè)計(jì)規(guī)范》GB50193-93第3.1.2.3條的規(guī)定。3.1.7.1同等采用〈二氧化碳滅火系統(tǒng)設(shè)計(jì)規(guī)范〉GB50193-93第3.1.3.1條的規(guī)定。3.1.7.2本條規(guī)定在噴頭與保護(hù)對(duì)象之間噴頭噴射角范圍內(nèi)不應(yīng)有遮擋物。是因?yàn)殪F滴噴射到遮擋物表面后會(huì)有一部分結(jié)成水滴流淌,降低滅火效果。3.1.8.1本條規(guī)定對(duì)于兩個(gè)或兩個(gè)以上的防護(hù)區(qū),細(xì)水霧滅火系統(tǒng)允許采用組合分配方式,但瓶組儲(chǔ)水量或泵組流量應(yīng)按最大區(qū)計(jì)算。3.1.8.2本條考慮瓶組式細(xì)水霧組合分配滅火系統(tǒng)的儲(chǔ)水量是一定的,如果在規(guī)定的時(shí)間內(nèi)不能有效控制火勢(shì),則沒有過量的水來補(bǔ)充。為了提高系統(tǒng)可靠性,降低火災(zāi)失控的概率,規(guī)定最多保護(hù)8出上述防護(hù)區(qū)或保護(hù)對(duì)象數(shù)量應(yīng)另外設(shè)置滅火系統(tǒng)。因泵組式細(xì)水霧系統(tǒng)能夠連續(xù)供水噴霧,系統(tǒng)可靠性較高,本條對(duì)泵組式細(xì)水霧組合分配滅火系統(tǒng)未作相應(yīng)規(guī)定。3.1.9為了在細(xì)水霧滅火系統(tǒng)安裝、調(diào)試結(jié)束或投入使用后,檢驗(yàn)系統(tǒng)的可靠性,測(cè)試系統(tǒng)能否正常啟動(dòng),要求在每一個(gè)保護(hù)區(qū)設(shè)置系統(tǒng)動(dòng)作試驗(yàn)裝置。系統(tǒng)動(dòng)作試驗(yàn)裝置是由多個(gè)閥門、管道、泄水口及固定支架組成,設(shè)置于區(qū)域控制閥與水霧噴頭之間的目的主要是為了在系統(tǒng)動(dòng)作試驗(yàn)過程中,避免開式噴頭造成誤噴現(xiàn)象。3.1.10本條對(duì)系統(tǒng)類型的選擇作了指引,而不同的項(xiàng)目選用由設(shè)計(jì)者根據(jù)產(chǎn)品的特性、火災(zāi)的種類——即危險(xiǎn)等級(jí)的不同、火災(zāi)報(bào)警器與噴頭動(dòng)作的時(shí)間差、以及保護(hù)區(qū)對(duì)水漬損失要求等綜合因素確定。3.1.11本條針對(duì)開式系統(tǒng)而言,這主要從現(xiàn)有市場(chǎng)產(chǎn)品設(shè)備配置的經(jīng)濟(jì)性和必要性而定。在實(shí)際設(shè)計(jì)中應(yīng)根據(jù)保護(hù)區(qū)的燃燒種類,火災(zāi)損失和蔓延速度,且應(yīng)特別注意系統(tǒng)的響應(yīng)時(shí)間符合本規(guī)范第3.2.6條規(guī)定。3.1.12本條適用閉式噴頭系統(tǒng)保護(hù)區(qū)計(jì)算作用面積水量,其含義同我國(guó)現(xiàn)行《自動(dòng)噴水滅火系統(tǒng)設(shè)計(jì)規(guī)范》相同。3.2.1目前細(xì)水霧滅火系統(tǒng)產(chǎn)品種類繁多、產(chǎn)品標(biāo)準(zhǔn)不一、參數(shù)各異,因此規(guī)定基本設(shè)計(jì)參數(shù)應(yīng)根據(jù)防護(hù)區(qū)和保護(hù)對(duì)象的具體情況確定。3.2.2表3-1規(guī)定的累積噴霧時(shí)間是根據(jù)實(shí)體滅火實(shí)驗(yàn)結(jié)果附加保險(xiǎn)系數(shù)并參考NFPA未涉及的保護(hù)對(duì)象,可通過實(shí)驗(yàn)確定。3.2.3.1噴頭是細(xì)水霧滅火系統(tǒng)的關(guān)鍵組件,種類繁多、各廠家標(biāo)準(zhǔn)不一,難以對(duì)其參數(shù)做出統(tǒng)一規(guī)定。因此,在選擇噴頭過程中,只能依據(jù)各廠家提供的技術(shù)資料進(jìn)行選擇。這里必須強(qiáng)調(diào)的是,廠家提供的噴頭技術(shù)資料是必須經(jīng)過國(guó)家有關(guān)消防產(chǎn)品檢測(cè)機(jī)構(gòu)檢測(cè)認(rèn)可的產(chǎn)品。廠家在提供這類資料時(shí),同時(shí)還應(yīng)提供噴頭在最不利情況或最大防護(hù)區(qū)尺寸下?lián)渚韧惢馂?zāi)的相關(guān)證明材料。3.2.3.2為了把細(xì)水霧均勻、迅速地送達(dá)防護(hù)區(qū)每個(gè)角落,全淹沒系統(tǒng)噴頭宜均衡布置在防護(hù)區(qū)頂部。由于細(xì)水霧脫離噴頭后沖量極小,因此對(duì)于高空間或較高物體應(yīng)分層布置噴頭,以期把細(xì)水霧均勻、迅速地送達(dá)防護(hù)區(qū)每個(gè)角落。本條規(guī)定了細(xì)水霧系統(tǒng)中噴頭的設(shè)計(jì)基本原則,噴頭的計(jì)算和設(shè)計(jì)必須根據(jù)被保護(hù)區(qū)的特點(diǎn)進(jìn)行配置,其中需要確定的因素有:噴頭間最大間隔;噴頭距墻最大距離;噴頭距天花板最大距離;噴頭最小間距;細(xì)水霧系統(tǒng)噴頭排列方式;決定噴頭數(shù),計(jì)算房間長(zhǎng)度部分所需的噴頭數(shù):(無(wú)條件進(jìn)位成整數(shù))沿著房間長(zhǎng)度部分之噴頭數(shù)=長(zhǎng)度÷最大噴頭間距計(jì)算房間寬度部分所需的噴頭數(shù):(無(wú)條件進(jìn)位成整數(shù))沿著房間寬度部分之噴頭數(shù)=寬度÷最大噴頭間距決定噴頭間距計(jì)算噴頭在房間長(zhǎng)度方向上真正的間距在格子型布置之長(zhǎng)度方向上,間距如下:格子型布置之長(zhǎng)度方向上之噴頭間距=房間長(zhǎng)度÷沿著房間長(zhǎng)度部分之噴頭數(shù)噴頭距長(zhǎng)度方向上端墻距離:距離墻最近之噴頭,距離不得大于格子型布置之長(zhǎng)度方向上噴頭間距的一半。噴頭距端墻距離≦格子型布置之長(zhǎng)度方向噴頭間距÷2計(jì)算噴頭在房間寬度方向上真正的間距在格子型布置之寬度方向上,間距如下:格子型布置之寬度方向上的噴頭間距=房間寬度÷沿著房間寬度部分之噴頭數(shù)噴頭距寬度方向上端墻距離:距端墻最近之噴頭,距離不得大于格子型布置之寬度方向之噴頭間距的一半。噴頭距端墻距離≦格子型布置的寬度方向的噴頭間距3.2.3.33.0m1.5m火實(shí)驗(yàn)中也采用了同樣噴頭間距范圍。3.2.3.4本條要求根據(jù)噴頭噴射特性進(jìn)行系統(tǒng)設(shè)計(jì),是整個(gè)系統(tǒng)能夠有效實(shí)施滅火的必要保證。3.2.3.6本條規(guī)定是根據(jù)公安部天津消防科學(xué)研究所委托天津電力實(shí)驗(yàn)研究院進(jìn)行的高壓細(xì)水霧系統(tǒng)帶電噴霧實(shí)驗(yàn)的結(jié)果制訂的。由于細(xì)水霧具有良好的電絕緣性能,因此細(xì)水霧系統(tǒng)可用于撲滅電氣設(shè)備火災(zāi),但是細(xì)水霧噴頭和管道,均要與帶電的電器部件保持一定的距離。鑒于上述原因,細(xì)水霧噴頭、管道與高壓電氣設(shè)備帶電(裸露)部分的最小安全靜距是設(shè)計(jì)中不可忽略的問題,各國(guó)相應(yīng)的規(guī)范、標(biāo)準(zhǔn)均作了具體規(guī)定。NFPA750中1-7:細(xì)水霧系統(tǒng)設(shè)備與帶電無(wú)絕緣電氣設(shè)備的間距,見下表:TableA-1-7.2.1細(xì)水霧系統(tǒng)設(shè)備與帶電無(wú)絕緣電氣設(shè)備的間距NominalSystemVoltageMaximumDesignMinimumClearance1(kV)SystemBIL2(kV)Voltage(kV)In.MmTo13.814.511071782324.31501025434.536.5200133304648.5250174326972.5350256351151215504210671381456505012701611697505814732302429007619301050842134345362105084213413001042642500550150012431501800144365876580020501674242本條規(guī)定了細(xì)水霧噴頭、管道與高壓帶電(裸露)部分的最小安全凈距離。3.2.4本條是借鑒了氣體滅火系統(tǒng)的有關(guān)規(guī)定而制定的。3.2.4.2本條規(guī)定的細(xì)水霧滅火系統(tǒng)儲(chǔ)氣容器和儲(chǔ)水容器的數(shù)量比應(yīng)為13,且容器容積應(yīng)一致,是形成細(xì)水霧的基本保證。3.2.5.1單個(gè)噴頭的流量q=K10P為通用算式,不同型號(hào)的噴頭具有不同的K值計(jì)算噴頭的流量。當(dāng)保護(hù)對(duì)象發(fā)生時(shí),細(xì)水霧滅火系統(tǒng)通過噴頭實(shí)施噴霧滅火或防護(hù)冷卻,因此本規(guī)范規(guī)定系統(tǒng)的計(jì)算流量按系統(tǒng)啟動(dòng)后同時(shí)噴霧的噴頭流量之和確定。本規(guī)范細(xì)水霧滅火系統(tǒng)的計(jì)算流量,從最不利點(diǎn)噴頭開始,沿程按同時(shí)動(dòng)作的每個(gè)細(xì)水霧噴頭實(shí)際工作壓力逐個(gè)計(jì)算其流量,然后累計(jì)同時(shí)動(dòng)作的噴頭總流量確定為系統(tǒng)流量。3.2.5.2本公式所給出的系統(tǒng)用水量為系統(tǒng)流量與噴射累積時(shí)間之和。3.2.5.3系統(tǒng)儲(chǔ)水量3.2.5.3.1因此,儲(chǔ)水量可按用水量進(jìn)行計(jì)算。該式計(jì)算示例:假設(shè):按3.2.3.1系統(tǒng)布置10只噴頭(n=10K=0.5,噴霧時(shí)間為t=20min,選用V0=80L儲(chǔ)水瓶,充裝率λ=0.99,則:系統(tǒng)用水量=1.1*0.5*10*20=110L,每瓶?jī)?chǔ)水量=0.99*80=79.2L,儲(chǔ)水容器的數(shù)量N=110/79.2=2只儲(chǔ)水瓶(圓整)3.2.5.3.2為了安全起見,在設(shè)定水箱儲(chǔ)水量時(shí),在滅火用水量的基礎(chǔ)上加設(shè)了一定量的安全系數(shù)。3.2.6細(xì)水霧滅火系統(tǒng)的響應(yīng)時(shí)間是從探測(cè)器動(dòng)作到報(bào)警控制器輸出啟動(dòng)信號(hào)至細(xì)水霧滅火裝置的時(shí)間。且從系統(tǒng)啟動(dòng)到噴頭噴出細(xì)水霧的時(shí)間實(shí)際上也限制了系統(tǒng)管道的長(zhǎng)度。這兩個(gè)時(shí)間之和不大于65s,也是實(shí)體火災(zāi)實(shí)驗(yàn)的結(jié)果。本條規(guī)定的細(xì)水霧滅火系統(tǒng)的響應(yīng)時(shí)間,3.2.7中高壓系統(tǒng)管網(wǎng)計(jì)算等同采用NFPA750給出的Darcy-Weisbach采用NFPA750給出的Hazen-Williams計(jì)算公式,密度ρ和動(dòng)力粘度μ參考NFPA750提供的數(shù)據(jù)和我國(guó)化工手冊(cè)公布的數(shù)據(jù)。4系統(tǒng)組件4.1一般規(guī)定4.1.1經(jīng)國(guó)家固定滅火系統(tǒng)及耐火構(gòu)件質(zhì)量監(jiān)督檢驗(yàn)中心檢測(cè)合格,說明該廠商生產(chǎn)的細(xì)水霧滅火系統(tǒng)成套產(chǎn)品的技術(shù)性能達(dá)到了標(biāo)準(zhǔn)規(guī)定的要求。4.1.2本條規(guī)定在貯存容器上設(shè)置耐久的固定標(biāo)牌,目的是為了便于對(duì)滅火系統(tǒng)進(jìn)行驗(yàn)收、檢查和維護(hù)。由于細(xì)水霧滅火系統(tǒng)具有腐蝕小、久貯不變的優(yōu)點(diǎn),,儲(chǔ)水容器和儲(chǔ)氣容器可以使用相當(dāng)長(zhǎng)的時(shí)間,甚至可達(dá)幾十年之久。因此,設(shè)置一個(gè)耐久的固定標(biāo)牌是必要的。4.1.3解釋同上。4.2組件要求4.2.1過濾器過濾器是細(xì)水霧滅火系統(tǒng)關(guān)鍵部件之一。對(duì)于以水泵供水的系統(tǒng),儲(chǔ)水箱前的供水管、水泵進(jìn)水口前應(yīng)設(shè)過濾器。對(duì)于預(yù)制式系統(tǒng),根據(jù)該系統(tǒng)本身的要求,設(shè)置過濾器。有的噴頭自帶過濾器,該過濾器的應(yīng)作為噴頭的組80%。4.2.2噴頭噴嘴是細(xì)水霧滅火系統(tǒng)最為重要的部件,其技術(shù)參數(shù)應(yīng)該是有關(guān)檢測(cè)機(jī)構(gòu)認(rèn)可的數(shù)據(jù)。不論是工程設(shè)計(jì)系統(tǒng)還是預(yù)制系統(tǒng),都應(yīng)該在制造商的技術(shù)手冊(cè)內(nèi)提供文中所列的各項(xiàng)技術(shù)參數(shù),為工程設(shè)計(jì)提供基本的設(shè)計(jì)依據(jù)。4.2.3安全泄壓裝置中壓、高壓細(xì)水霧滅火系統(tǒng)的系統(tǒng)工作壓力明顯高于其它自動(dòng)噴水滅火系統(tǒng)的系統(tǒng)工作壓力,因此,對(duì)于儲(chǔ)氣容器和儲(chǔ)水容器的安全性應(yīng)引起足夠的重視。為了保障細(xì)水霧滅火系統(tǒng)的儲(chǔ)氣容器、儲(chǔ)水容器不會(huì)因某項(xiàng)事故環(huán)GB150力容器安全技術(shù)監(jiān)察規(guī)程》中也要求壓力容器設(shè)安全泄壓裝置,且應(yīng)實(shí)行定期檢驗(yàn)制度。具體的設(shè)置方案應(yīng)由設(shè)計(jì)配合生產(chǎn)廠家完成。4.2.4控制閥4.2.4.1控制閥是細(xì)水霧滅火系統(tǒng)的主要部件之一,功能包括了啟動(dòng)細(xì)水霧滅火系統(tǒng)和在組合分配系統(tǒng)中選擇保護(hù)區(qū)的功用。操作方式上不但規(guī)定了電動(dòng)而且還手動(dòng)應(yīng)急操作,這主要考慮到萬(wàn)一電動(dòng)操作失靈(包括停電),應(yīng)能通過人為的手動(dòng)操作啟動(dòng)滅火系統(tǒng)進(jìn)行滅火。4.2.4.2在組合分配系統(tǒng)中,每個(gè)防護(hù)區(qū)或保護(hù)對(duì)象應(yīng)設(shè)置一個(gè)控制閥。在火災(zāi)發(fā)生時(shí),可以有選擇地打開出現(xiàn)火情的防護(hù)區(qū)或保護(hù)對(duì)象的控制閥,噴射細(xì)水霧進(jìn)行滅火。控制閥上設(shè)有對(duì)應(yīng)防護(hù)區(qū)或保護(hù)對(duì)象的永久性銘牌是防止操作時(shí)出現(xiàn)差錯(cuò)。4.2.5容器和泵組4.2.5.1專用設(shè)備間內(nèi)環(huán)境溫度要求4~50℃,主要考慮到滅火介質(zhì)水及系統(tǒng)部件對(duì)環(huán)境溫度的要求,設(shè)置在專用設(shè)備間內(nèi)主要是為了便于管理及安全。對(duì)于瓶組式細(xì)水霧滅火系統(tǒng),如果設(shè)置在防護(hù)區(qū)外有困難時(shí),可以設(shè)置在防護(hù)區(qū)內(nèi),但為了應(yīng)用鋼制瓶組柜加以保護(hù)。4.2.5.2專用設(shè)備間的耐火等級(jí)不應(yīng)低于二級(jí),與《建筑設(shè)計(jì)防火規(guī)范》對(duì)水泵房的等級(jí)相同。室內(nèi)應(yīng)保持干燥,可避免容器、管道、電氣儀表等因潮濕而銹蝕。良好通風(fēng)可避免因檢修或加壓氣體氮?dú)獾男孤┰斐稍O(shè)備間內(nèi)濃度過高而對(duì)人身造成危害。4.2.6管道、連接件及支架4.2.6.1因?yàn)榧?xì)水霧噴頭對(duì)水質(zhì)要求很高,如果管道銹蝕,會(huì)造成噴頭的堵塞,且細(xì)水霧滅火系統(tǒng)壓力較高,所以本條規(guī)定選用必須無(wú)縫鋼管。本條所規(guī)定的各種管道公稱通徑和壁厚,是通過計(jì)算與試驗(yàn)所得到,且滿足了管道的各種連接方法。4.2.6.3本條的要求,主要使細(xì)水霧滅火系統(tǒng)的管道安裝牢固,不產(chǎn)生徑向晃動(dòng)與軸向竄動(dòng)。4.2.7細(xì)水霧滅火系統(tǒng)的報(bào)警和控制線路應(yīng)穿金屬管保護(hù)符合GB50116《火災(zāi)自動(dòng)報(bào)警系統(tǒng)設(shè)計(jì)規(guī)范》的要求。對(duì)于細(xì)水霧滅火系統(tǒng),保護(hù)特殊的火災(zāi)場(chǎng)所時(shí),采用間歇方式噴射細(xì)水霧滅火更有效,這就需要采用程控、間歇方式控制,因此探測(cè)器和報(bào)警控制器應(yīng)具備循環(huán)探測(cè)和控制的功能,且報(bào)警和控制線路在火災(zāi)下應(yīng)能正常工作,所以應(yīng)采用防火電纜。5操作與控制5.0.1細(xì)水霧滅火系統(tǒng)的防護(hù)區(qū)或保護(hù)對(duì)象有可能無(wú)人在場(chǎng),即使經(jīng)常有人,有時(shí)也不易很快發(fā)現(xiàn)火災(zāi)。所以一般應(yīng)有自動(dòng)控制,以保證一旦失火便能迅速將其撲滅。但自動(dòng)控制有可能失靈,故要求系統(tǒng)同時(shí)應(yīng)有手動(dòng)控制。如果人為發(fā)現(xiàn)了火災(zāi)在先,也可通過手動(dòng)控制啟動(dòng)滅火系統(tǒng)。為了能迅速啟動(dòng)滅火系統(tǒng),要求以一個(gè)控制動(dòng)作就能使整個(gè)系統(tǒng)動(dòng)作。考慮到自動(dòng)控制和手動(dòng)控制萬(wàn)一失靈(包括停電),系統(tǒng)應(yīng)有應(yīng)急啟動(dòng)方式,應(yīng)急啟動(dòng)裝置經(jīng)常是機(jī)械的,如用手推動(dòng)電磁閥和選擇閥手柄等。5.0.2本條規(guī)定了細(xì)水霧滅火系統(tǒng)采用火災(zāi)探測(cè)器進(jìn)行火災(zāi)探測(cè)時(shí)的具體要求。的誤動(dòng)作會(huì)造成停工、停產(chǎn),帶來不必要的經(jīng)濟(jì)損失。為了盡可能減少甚至避免探測(cè)器誤報(bào)引起的誤動(dòng)作,通常設(shè)置兩種類型或兩組同一類型的探測(cè)器進(jìn)行復(fù)合探測(cè)。本條規(guī)定的“應(yīng)在接受到兩個(gè)獨(dú)立的火災(zāi)信號(hào)后才能啟動(dòng),是指只有當(dāng)兩種不同類型或兩組同一類型的火災(zāi)探測(cè)器均檢測(cè)出保護(hù)場(chǎng)所存在火災(zāi)時(shí),才能發(fā)出啟動(dòng)滅火系統(tǒng)的指令。5.0.3手動(dòng)控制應(yīng)不受火災(zāi)影響,一般在防護(hù)區(qū)外面或遠(yuǎn)離保護(hù)對(duì)象的地方進(jìn)行。6安全要求6.0.1本條規(guī)定在每個(gè)防護(hù)區(qū)內(nèi)和防護(hù)區(qū)入口處應(yīng)設(shè)置火災(zāi)報(bào)警信號(hào),其目的在于提醒防護(hù)區(qū)內(nèi)的人員迅速撤離防護(hù)區(qū),以免受到火災(zāi)的危害。在火災(zāi)報(bào)警信號(hào)和滅火系統(tǒng)施放之間一般有一定的時(shí)間間隔,這給防護(hù)區(qū)的人員提供了撤離時(shí)間,以及判斷防護(hù)區(qū)的火災(zāi)是否可以用手提式滅火器撲滅,而不必啟動(dòng)細(xì)水霧滅火系統(tǒng)。如果防護(hù)區(qū)內(nèi)的人員發(fā)現(xiàn)火災(zāi)很小,就沒有必要啟動(dòng)滅火系統(tǒng),可將滅火系統(tǒng)啟動(dòng)控制部分切斷。本條規(guī)定必須有手動(dòng)切除報(bào)警信號(hào)的操作機(jī)構(gòu),是為了防止誤報(bào),也是為了在人們已獲知火災(zāi)信號(hào)或已投入撲救火災(zāi)時(shí),無(wú)需報(bào)警信號(hào),特別是聲報(bào)警信號(hào)的情況下應(yīng)能手動(dòng)切除。6.0.2本條是從保證人員的安全角度出發(fā)而制定的。規(guī)定了人員撤離防護(hù)區(qū)的時(shí)間和迅速撤離的安全措施。一般來講,采用細(xì)水霧滅火系統(tǒng)的防護(hù)區(qū)一旦發(fā)生火災(zāi)報(bào)警信號(hào),人員應(yīng)立即開始撤離,到發(fā)出施放滅火劑的報(bào)警時(shí),人員應(yīng)全部撤出。這一段預(yù)報(bào)警時(shí)間也就是人員疏散時(shí)間。防護(hù)區(qū)面積大,人員疏散距離遠(yuǎn),則預(yù)報(bào)警時(shí)間應(yīng)長(zhǎng)。反之則預(yù)報(bào)警時(shí)間可短。這一時(shí)間是人為規(guī)定的,可根據(jù)防護(hù)區(qū)的具體情況確定,但不應(yīng)大于30s。當(dāng)防護(hù)區(qū)內(nèi)無(wú)人時(shí),應(yīng)取消預(yù)報(bào)警時(shí)間。6.0.3防護(hù)區(qū)入口應(yīng)設(shè)噴霧指示燈。以免受到火災(zāi)或其它危害。同時(shí)也有提醒防護(hù)區(qū)內(nèi)的人員迅速撤離防護(hù)區(qū)的作用。6.0.4當(dāng)系統(tǒng)管道設(shè)置在有爆炸危險(xiǎn)粉塵、可燃?xì)怏w、蒸汽的場(chǎng)所時(shí),應(yīng)設(shè)防靜電接地。本條規(guī)定是為了防止由于靜電而引起爆炸事故。當(dāng)細(xì)水霧滅火系統(tǒng)施放滅火劑時(shí),不接地的導(dǎo)體會(huì)產(chǎn)生靜電而帶電,這些帶電的導(dǎo)體可能會(huì)向其他物體放電。因此,對(duì)于安裝在有爆炸危險(xiǎn)粉塵、可燃?xì)怏w、蒸汽的場(chǎng)所的細(xì)水霧滅火系統(tǒng)的管網(wǎng),應(yīng)設(shè)防靜電接地裝置。在進(jìn)行系統(tǒng)設(shè)計(jì)時(shí),一般要求管網(wǎng)對(duì)地電阻不大于10Ω。6.0.5防護(hù)區(qū)的門應(yīng)向疏散方向開啟,并能自動(dòng)關(guān)閉。在任何情況下均能從防護(hù)區(qū)內(nèi)打開。響人員疏散。同時(shí)要求人員疏散后門能自動(dòng)關(guān)閉,以利于防護(hù)區(qū)內(nèi)細(xì)水霧滅火劑保持一定的滅火濃度,防止滅火劑流失,影響滅火效果。還可避免因某種原因而被困入防護(hù)區(qū)的人員,能從防護(hù)區(qū)內(nèi)將門打開順利撤離。防護(hù)區(qū)自動(dòng)關(guān)閉門的設(shè)計(jì),強(qiáng)調(diào)當(dāng)門關(guān)閉后,在如何情況下都能從防護(hù)區(qū)內(nèi)部打開。7施工、驗(yàn)收7.1基本規(guī)定7.1.1質(zhì)量管理7.1.1.1“30號(hào)令驗(yàn)收統(tǒng)一標(biāo)準(zhǔn)》GB50300(“統(tǒng)一標(biāo)準(zhǔn),要求施工單位在施工現(xiàn)場(chǎng)應(yīng)有技術(shù)標(biāo)準(zhǔn)和工程質(zhì)量檢測(cè)儀器設(shè)備,對(duì)施工過程實(shí)現(xiàn)質(zhì)量過程控制。7.1.1.2按照“消防法“30號(hào)令的有關(guān)要求,細(xì)水霧滅火系統(tǒng)的施工圖設(shè)計(jì)文件必須經(jīng)過當(dāng)?shù)氐南辣O(jiān)督機(jī)構(gòu)進(jìn)行審核,審核批準(zhǔn)后方可施工。有重大設(shè)計(jì)變更的圖紙應(yīng)重新報(bào)原審核機(jī)關(guān)進(jìn)行審核,審核批準(zhǔn)后方可進(jìn)行施工。7.1.1.3本條規(guī)定的“經(jīng)批準(zhǔn)是指經(jīng)由建設(shè)單位和監(jiān)理單位的批準(zhǔn)。按“統(tǒng)一標(biāo)準(zhǔn)的要求,結(jié)合調(diào)研了解到施工組織設(shè)計(jì)或施工方案對(duì)指導(dǎo)工程施工和提高施工質(zhì)量、明確質(zhì)量驗(yàn)收標(biāo)準(zhǔn)確有實(shí)效。同時(shí),監(jiān)理或建設(shè)單位審查利于互相遵守。7.1.1.4本條對(duì)細(xì)水霧滅火系統(tǒng)的施工提出了具體的要求。由于細(xì)水霧滅火系統(tǒng)的滅火效果與防護(hù)區(qū)內(nèi)保護(hù)對(duì)象的擺放形式有很大的關(guān)聯(lián)性,因此,保護(hù)對(duì)象以及可燃物的擺放形式及部位不能隨意變化。存在著一旦擺放形式發(fā)生變化后,細(xì)水霧滅火系統(tǒng)的設(shè)計(jì)也要相應(yīng)隨之變化的可能。同樣,設(shè)備間的設(shè)置條件也應(yīng)相對(duì)固定,由于細(xì)水霧滅火系統(tǒng)的動(dòng)作是在高壓驅(qū)動(dòng)下的水流或水、氣混合流的一種噴射性動(dòng)作,設(shè)備設(shè)置的位置、管網(wǎng)布置等諸多條件將對(duì)細(xì)水霧的滅火產(chǎn)生影響。因此,在未經(jīng)設(shè)計(jì)人員重新核算并認(rèn)可的情況下,不應(yīng)對(duì)設(shè)備間的設(shè)置條件進(jìn)行改動(dòng)。因此,在系統(tǒng)施工過程中,應(yīng)根據(jù)通過核準(zhǔn)的設(shè)計(jì)方案進(jìn)行選配,只有這樣,才能保證系統(tǒng)運(yùn)行的安全可靠性。細(xì)水霧滅火系統(tǒng)噴射滅火的形式是介于水噴霧和氣體滅火之間的一種滅火系統(tǒng),其噴射出的細(xì)水霧滴極易飄散,因此,其預(yù)埋件的設(shè)置和對(duì)孔洞設(shè)計(jì)及施工的要求是比較嚴(yán)格的,不應(yīng)隨意改動(dòng)。7.1.15據(jù)“統(tǒng)一標(biāo)準(zhǔn)”的要求,所有工程項(xiàng)目都應(yīng)納入統(tǒng)一的工程分類體系。將細(xì)水霧滅火系統(tǒng)確定為子分部工程的原因是以建筑整體為一個(gè)完整工程,以消防工程為分部工程。由此下分,由于細(xì)水霧滅火系統(tǒng)是消防工程的一部分,因此確定為子分部工程。而細(xì)水霧滅火系統(tǒng)中的各項(xiàng)施工及調(diào)試則為分項(xiàng)工程。7.1.1.6細(xì)水霧滅火系統(tǒng)是由多組件和材料組成,經(jīng)過程圖紙,并施工調(diào)試完成的完整系統(tǒng),因此,在其竣工時(shí),必須經(jīng)過整體驗(yàn)收合格后,才能確保系統(tǒng)安全運(yùn)行。7.1.1.7本條的規(guī)定是按“消防法“30號(hào)令有關(guān)條文進(jìn)行要求的,同時(shí)也是為了杜絕那些不具備施工資質(zhì)的小包工隊(duì)在不具備系統(tǒng)施工的技術(shù)素質(zhì)及條件的情況下承接系統(tǒng)
溫馨提示
- 1. 本站所有資源如無(wú)特殊說明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請(qǐng)下載最新的WinRAR軟件解壓。
- 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請(qǐng)聯(lián)系上傳者。文件的所有權(quán)益歸上傳用戶所有。
- 3. 本站RAR壓縮包中若帶圖紙,網(wǎng)頁(yè)內(nèi)容里面會(huì)有圖紙預(yù)覽,若沒有圖紙預(yù)覽就沒有圖紙。
- 4. 未經(jīng)權(quán)益所有人同意不得將文件中的內(nèi)容挪作商業(yè)或盈利用途。
- 5. 人人文庫(kù)網(wǎng)僅提供信息存儲(chǔ)空間,僅對(duì)用戶上傳內(nèi)容的表現(xiàn)方式做保護(hù)處理,對(duì)用戶上傳分享的文檔內(nèi)容本身不做任何修改或編輯,并不能對(duì)任何下載內(nèi)容負(fù)責(zé)。
- 6. 下載文件中如有侵權(quán)或不適當(dāng)內(nèi)容,請(qǐng)與我們聯(lián)系,我們立即糾正。
- 7. 本站不保證下載資源的準(zhǔn)確性、安全性和完整性, 同時(shí)也不承擔(dān)用戶因使用這些下載資源對(duì)自己和他人造成任何形式的傷害或損失。
最新文檔
- 2025年經(jīng)濟(jì)學(xué)基礎(chǔ)理論考試試卷及答案
- 2025年酒店管理與運(yùn)營(yíng)考試試卷及答案
- 2025年經(jīng)濟(jì)學(xué)研究生入學(xué)考試試卷及答案
- 商品砂漿合同協(xié)議
- 品牌代理銷售合同協(xié)議
- 德國(guó)公司服務(wù)合同協(xié)議
- 2025綠茵湖畔住宅小區(qū)物業(yè)管理服務(wù)合同
- 2025全國(guó)獨(dú)家分銷總合同全國(guó)獨(dú)家分銷合同范本
- 品牌使用協(xié)議書范本
- 2025湖南建筑工地地下行業(yè)勞動(dòng)合同范本
- 2025哈爾濱市木蘭縣輔警考試試卷真題
- 《勞動(dòng)法律法規(guī)與政策》課件
- (二模)2025年廣州市普通高中高三畢業(yè)班綜合測(cè)試(二)生物試卷(含答案)
- 浙江省麗水市發(fā)展共同體2024-2025學(xué)年高一下學(xué)期期中聯(lián)考政治試題(含答案)
- GB/T 45460-2025鋼絲繩在無(wú)軸向載荷條件下鋼絲繩徑向剛度的測(cè)定
- (四調(diào))武漢市2025屆高中畢業(yè)生四月調(diào)研考試 數(shù)學(xué)試卷(含答案詳解)
- 超越廣告-南京林業(yè)大學(xué)中國(guó)大學(xué)mooc課后章節(jié)答案期末考試題庫(kù)2023年
- 上海眾辰SP500系列空壓機(jī)一體機(jī)使用手冊(cè)V104.04
- 危廢處置方案完全示范版
- 大班生活習(xí)慣好教案教學(xué)5篇
- 機(jī)械基礎(chǔ)中職帶傳動(dòng)教案
評(píng)論
0/150
提交評(píng)論