




版權說明:本文檔由用戶提供并上傳,收益歸屬內(nèi)容提供方,若內(nèi)容存在侵權,請進行舉報或認領
文檔簡介
1、DB42/0741993(2002年修訂)PAGE 1聯(lián)合發(fā)布DB42聯(lián)合發(fā)布DB422008-實施2008-發(fā)布武漢城市圈居住建筑節(jié)能設計標準Design Standard for Energy Efficiency of Residential Buildings in Wuhan City Zones(征求意見稿)DB42/ 2008湖北省地方標準DB42/-2008 PAGE PAGE II目次TOC o 1-3 h z u HYPERLINK l _Toc217297312 目次 PAGEREF _Toc217297312 h I HYPERLINK l _Toc217297313
2、前言 PAGEREF _Toc217297313 h II HYPERLINK l _Toc217297314 1 總則 PAGEREF _Toc217297314 h 1 HYPERLINK l _Toc217297315 2 規(guī)范性引用文件 PAGEREF _Toc217297315 h 1 HYPERLINK l _Toc217297316 3 術語 PAGEREF _Toc217297316 h 1 HYPERLINK l _Toc217297317 4室內(nèi)熱環(huán)境和建筑節(jié)能設計計算參數(shù) PAGEREF _Toc217297317 h 2 HYPERLINK l _Toc21729731
3、8 5 建筑和建筑圍護結(jié)構節(jié)能設計 PAGEREF _Toc217297318 h 2 HYPERLINK l _Toc217297319 6 采暖、通風和空氣調(diào)節(jié)節(jié)能設計 PAGEREF _Toc217297319 h 5 HYPERLINK l _Toc217297320 7 照明節(jié)能設計 PAGEREF _Toc217297320 h 10 HYPERLINK l _Toc217297321 8 太陽能熱水系統(tǒng)與建筑一體化節(jié)能設計 PAGEREF _Toc217297321 h 11 HYPERLINK l _Toc217297322 附錄A (規(guī)范性附錄)外墻平均傳熱系數(shù)與平均熱惰性指
4、標的計算 PAGEREF _Toc217297322 h 14 HYPERLINK l _Toc217297323 附錄B (規(guī)范性附錄)建筑物體形系數(shù)和窗墻面積比的計算 PAGEREF _Toc217297323 h 20 HYPERLINK l _Toc217297324 附錄C (規(guī)范性附錄)空調(diào)器室外機擱置平臺(或擱板)的設置規(guī)定 PAGEREF _Toc217297324 h 22 HYPERLINK l _Toc217297325 附錄D (規(guī)范性附錄)固定外遮陽夏季的外遮陽系數(shù)的簡化計算和活動遮陽設施的太陽輻射透過率 PAGEREF _Toc217297325 h 23 HYPE
5、RLINK l _Toc217297326 附錄E (資料性附錄)外窗傳熱系數(shù)估算、常用國產(chǎn)玻璃光學和熱工性能參數(shù) PAGEREF _Toc217297326 h 25 HYPERLINK l _Toc217297327 附錄F (規(guī)范性附錄)建筑圍護結(jié)構設計文件編制深度 PAGEREF _Toc217297327 h 28 HYPERLINK l _Toc217297328 本標準用詞說明 PAGEREF _Toc217297328 h 29前言PAGE PAGE 47DB42/-2008 PAGE 48居住建筑節(jié)能設計標準1 總則1.0.1為貫徹國家有關節(jié)約能源、保護環(huán)境的法律、法規(guī)和政策
6、,改善建筑熱環(huán)境,提高采暖和空調(diào)的能源利用效率,制定本標準。1.0.2本標準適用于湖北省武漢城市圈各地新建、改建和擴建的居住建筑的建筑節(jié)能設計。1.0.3居住建筑的建筑熱工和暖通空調(diào)設計必須采取節(jié)能措施,在保證室內(nèi)熱環(huán)境質(zhì)量的前提下,進一步降低采暖空調(diào)能耗,使新建、改建和擴建的居住建筑在DB42/301的基礎上再降低30%。1.0.4居住建筑的節(jié)能設計,除應符合本標準外,尚應符合國家現(xiàn)行有關標準的規(guī)定。2 規(guī)范性引用文件下列文件中的條款通過本標準的引用而成為本標準的條款。凡是注日期的引用文件,其隨后所有的修改單(不包括勘誤的內(nèi)容)或修訂版均不適用于本標準,然而,鼓勵根據(jù)本標準達成協(xié)議的各方研究
7、是否可使用這些文件的最新版本。凡是不注日期的引用文件,其最新版本適用于本標準。GB 50176 民用建筑熱工設計規(guī)范GB 12021.3 房間空氣調(diào)節(jié)器能效限定值及能源效率等級3 術語3.0.1 建筑物體形系數(shù)(S)surface to volume ratio of building建筑物與室外大氣接觸的外表面積與其所包圍體積的比值。3.0.2 窗墻面面積比(wdw)area ratio of window to wall窗洞口面積與房間立面單元面積(即房間層高與開間定位線圍成的面積)的比值。3.0.3 圍護結(jié)構傳熱系數(shù)(K)heat transfer coefficient of buil
8、ding envelope在穩(wěn)態(tài)條件下,圍護結(jié)構兩側(cè)空氣溫度差為1K,1h內(nèi)通過1m2面積傳遞的熱量,單位為W/(K)。3.0.4 單一朝向外墻平均傳熱系數(shù)(Kmi)mean heat transter coefficient of a exernal wall考慮了墻上存在的熱橋影響后計算得到的單一朝向外墻傳熱系數(shù),單位為W/(K)。3.0.5 凸窗bay window凸出建筑外墻外表面的窗。4室內(nèi)熱環(huán)境和建筑節(jié)能設計計算參數(shù)4.0.1室內(nèi)熱環(huán)境設計計算參數(shù),應符合下列要求:臥室、起居室等居室室內(nèi)設計計算溫度采暖取18,空調(diào)取26;換氣次數(shù)取1.0 次/h。4.0.2建筑能耗計算設備能效比取
9、3.0,性能系數(shù)取1.9。5 建筑和建筑圍護結(jié)構節(jié)能設計5.1 一般規(guī)定5.1.1建筑群的規(guī)劃設計,單體建筑的平、立面設計,應有利于區(qū)域和室內(nèi)在夏季的自然通風,當室內(nèi)自然通風不良時,宜設置機械通風系統(tǒng)。規(guī)劃設計宜采取降低建筑密度、提高綠地率、以及其它有利于減輕區(qū)域熱島效應的措施。5.1.2建筑物宜采用南(南偏東22.50至南偏西22.50,含22.50)北適宜朝向布置,不宜采用東西(東或西偏南67.50至偏北67.50)不利朝向布置。5.1.3 建筑物的體形系數(shù)應符合表5.1.3限值的規(guī)定。建筑物體形系數(shù)的計算應符合附錄B的規(guī)定。表5.1.3 建筑物的體形系數(shù)限值建筑層數(shù)3層46層718層19
10、層建筑物體形系數(shù)0.550.400.350.305.1.4一個功能的房間不宜設置三面外墻。5.1.5 一個功能房間除在開間立面單元設置外窗之外,不宜同時在立面單元相鄰外墻上設置外窗。5.1.6 居住空間頂部的斜坡屋面不應設置透明天窗。5.1.7外窗(包括陽臺門透明部分)的窗地面積比不宜小于表5.1.7的規(guī)定。表5.1.7建筑窗地面積比房間功能客廳、餐廳、臥室、書房、廚房樓梯間窗地面積比1/71/125.1.8臥室、起居室(廳)、衛(wèi)生間的通風口可開啟的凈面積不應小于該房間地板面積的1/15(6層及6層以下)和1/20(7層及7層以上),廚房的通風開口凈面積不應小于其地板面積的1/10,并不得小于
11、0.6m2。5.1.9采用分體式空氣調(diào)節(jié)器時,應按室(或戶)設置房間空調(diào)器室外機的擱置平臺(或擱板),不得將室外機安裝在外保溫層上。室外機擱置平臺(或擱板)的設置應符合本標準附錄C的規(guī)定。5.2 建筑圍護結(jié)構節(jié)能設計5.2.1采暖空調(diào)房間外窗(包括陽臺門的透明部分)的窗墻面積比限值應符合表5.2.1的規(guī)定。窗墻面積比應按本標準附錄B第B.0.7條的規(guī)定計算。表5.2.1不同朝向外窗的窗墻面積比限值建筑類別外窗朝向窗墻面積比限值建筑類別建筑朝向窗墻面積比限值建筑層數(shù)3層南0.35建筑層數(shù)3層南0.40北、東0.30北、東、西0.25西0.25注:表中的“南”代表南偏東22.50(含22.50)至
12、南偏西22.50(含22.50),北代表北偏東22.50(含22.50)至北偏西22.50(含22.50),“東”代表東偏南67.50至東偏北67.50,“西”代表西偏南67.50至西偏北67.50。5.2.2不同朝向、不同窗墻面積比外窗(包括陽臺門透明部分)的傳熱系數(shù)、遮陽系數(shù)(夏季)、玻璃可見光透射比不應超過表5.2.2規(guī)定的限值。表5.2.2不同朝向、不同窗墻面積比外窗的傳熱系數(shù)、遮陽系數(shù)(夏季)、玻璃可見光透射比限值建筑層數(shù)建筑物體型系數(shù)S窗墻面積比wd/w外窗的傳熱系數(shù)注2K W/( K)遮陽系數(shù)(夏季)SC注2玻璃可見光透射比朝向朝向南北東西南北東、西3層S0.300.253.00
13、.250.203.00.500.550.500.540.252.60.250.252.60.500.500.450.302.40.300.252.40.450.500.400.352.22.20.350.450.30S0.400.253.00.250.203.00.400.500.400.252.60.250.252.60.400.500.350.302.40.300.252.40.350.500.300.352.22.20.300.453層S0.550.402.00.250.252.00.550.550.55注:1 表中的南、北、東、西同表5.2.1注1。2樓梯間、不住人閣樓、電梯機房外窗無
14、SC值要求,傳熱系數(shù)也可取K3.5(建筑層數(shù)3層)、K2.6(建筑層數(shù)3層)。3 南、北向有透明側(cè)向窗的凸窗(含轉(zhuǎn)角凸窗)的傳熱系數(shù)(包括側(cè)面和正面窗),應將表列規(guī)定的限值乘0.80的修正系數(shù)后采用。4遮陽系數(shù)SC窗的遮陽系數(shù)外遮陽的遮陽系數(shù)。窗的遮陽系數(shù)玻璃的遮陽系數(shù)(1-窗框比)。玻璃的遮陽系數(shù)各層玻璃和鍍膜層遮陽系數(shù)的乘積。PVCU和木窗的窗框比取0.300.40、鋁合金及彩鋼窗的窗框比取0.20或?qū)嶋H值。外遮陽設施的遮陽系數(shù)按附錄D的規(guī)定計算。5當表中遮陽系數(shù)SC值小于0.50時,各朝向外窗宜設置本標準附錄D第D.0.3條所列太陽輻射透過率20的活動外遮陽設施。設置活動外遮陽設施的外窗
15、,認定其遮陽系數(shù)符合表列限值的規(guī)定。5.2.3外窗和陽臺門應具有良好的氣密性能,起居室、餐廳、臥室(含書房)、衛(wèi)生間外窗和陽臺門的氣密性等級,不應低于現(xiàn)行國家標準建筑外窗氣密性能分級及檢測方法GB 71072002規(guī)定的4級,廚房、樓梯間、不住人閣樓、電梯機房外窗的氣密性等級,不應低于上述標準規(guī)定的3級。5.2.4圍護結(jié)構的熱工性能指標應符合表5.2.4的規(guī)定。其中,外墻的傳熱系數(shù)、熱惰性指標應考慮結(jié)構冷、熱橋的影響,取各朝向外墻的平均傳熱系數(shù)Kmi與平均熱惰性指標Dmi,其值應按本標準附錄A的規(guī)定計算。表5.2.4建筑圍護結(jié)構熱工性能限值部位建筑物體形系數(shù)S建筑層數(shù)3層建筑層數(shù)3層S0.30
16、0.30S0.3250.325S0.350.35S0.40S0.55傳熱系數(shù)K W/( K)熱惰性指標D屋面(含樓梯、電梯機房、頂窗屋面)注2、注3K0.40, D3.0K0.30D3.0外墻(含樓梯間、電梯機房、頂窗外墻)注3建筑朝向南北Kmi1.10,Dmi3.0;Kmi1.00,Dmi2.5Kmi1.0,Dmi3.0;Kmi0.9,Dmi2.5Kmi0.90,Dmi3.0;Kmi0.85,Dmi2.5Kmi0.85,Dmi3.0;Kmi0.80,Dmi2.5Kmi0.60 D3.0東西Kmi0.90,Dmi3.0;Kmi0.80,Dmi2.5Kmi0.80,Dmi3.0;Kmi0.70,
17、Dmi2.5Kmi0.70,Dmi3.0;Kmi0.65,Dmi2.5Kmi0.65,Dmi3.0;Kmi0.60,Dmi2.5分戶墻、分隔采暖空調(diào)與非采暖空調(diào)空間的隔墻,樓板K1.8底面接觸室外空氣的架空或外挑樓板K1.00或K0.65注6K0.9或K0.65注6K0.80或K0.65注6K0.70或K0.65注6K0.60或K0.50注6戶門K2.00K1.0陽臺門下部的門芯板K1.00K0.50架空地面,非采暖空調(diào)地下室和半地下室的頂板,與公共建筑銜接的樓板K0.65K0.60凸窗的頂板、側(cè)墻板、底板K0.70D2.0K0.60D2.0外窗按表5.2.2的規(guī)定限值注:1 當屋頂和外墻的K
18、、Kmi值滿足要求,但Dmi值(包括外墻各熱橋部位)不滿足要求時,應按照民用建筑熱工設計規(guī)范GB 5017693第5.1.1條驗算并滿足隔熱設計要求。2 居住空間頂部坡屋面的傳熱系數(shù)限值應按表列規(guī)定值乘下表所列修正系數(shù)值后采用:坡屋面?zhèn)鳠嵯禂?shù)限值的修正系數(shù)坡屋面坡度0.20.30.40.50.61.0K值修正系數(shù)0.89 0.860.810.760.700.47 表中其它坡度坡屋面的傳熱系數(shù)限值按表列值插值求取。3 當屋面、外墻的外表面為太陽輻射吸收系數(shù)大于0.70的深色飾面時,應將表中屋面(保溫屋面設置在閣樓樓板上的坡屋面除外)、外墻傳熱系數(shù)的限值乘以0.90的修正系數(shù)后采用。深色飾面外墻應
19、單獨計算其Kmi及Dmi值。4 表中的建筑朝向指建筑主立面朝向,南、北、東、西同表5.2.1注1。5 保溫坡屋面底部不住人閣樓的樓板傳熱系數(shù)限值應符合表中的規(guī)定。6 當架空樓板或外挑樓板的K0.65(3層)、0.50(3層)時,其表面積不參與體形系數(shù)的計算。5.2.5出屋面構件(裝飾構架或花架柱、排氣道、排煙道、女兒墻等)熱橋部位應做保溫處理,經(jīng)處理后的各構件傳熱系數(shù)應符合表5.2.4中屋面的規(guī)定。屋面不得取平均傳熱系數(shù)計算。當坡屋面底部為不住人閣樓時,屋面層保溫宜設置在閣樓樓板上。5.2.6除開敞式陽臺梁板、欄板及隔板、雨蓬等大型構件外,包括凸出外墻的柱、裝飾線條、小挑檐及天溝、大天溝內(nèi)的外
20、墻梁側(cè)面、門窗套及窗臺、變形縫(外墻、屋面、內(nèi)墻、樓地面各部位)等熱橋部位,應采取外(或內(nèi))保溫斷熱處理措施。其中,門窗洞口的頂面、側(cè)面及窗臺的保溫層最薄處厚度不得小于25mm,其它熱橋部位的保溫層不得小于同一朝向外墻的保溫層厚度。外門窗框與墻體之間的預留縫隙,應滿灌發(fā)泡聚氨酯,不得用砂漿填縫。內(nèi)墻面粉刷材料宜采用粉刷石膏砂漿或加氣混凝土墻專用保溫抹灰砂漿。5.2.7封閉陽臺的圍護結(jié)構應符合下列規(guī)定:1 當封閉陽臺與連通房間之間設置有符合第5.2.1條至第5.2.4條相應規(guī)定的隔墻和門窗時,封閉陽臺上的樓板、欄板及欄板上的外窗,均無熱工性能和氣密性要求;2 當封閉陽臺與房間直接連通時,封閉陽臺
21、上的外圍護結(jié)構和樓板應分別符合第5.2.1條至第5.2.4條的相應規(guī)定。5.2.8不宜設置凸窗(含轉(zhuǎn)角凸窗)。當設置凸窗時,窗的傳熱系數(shù)應符合第5.2.2條表5.2.2注3的規(guī)定。5.2.9圍護結(jié)構的外表面應采用淺色飾面材料,其太陽輻射吸收系數(shù)不得大于GB50176附表2.6中的0.70(綠化屋面除外)。當太陽輻射吸收系數(shù)大于0.70的規(guī)定限值時,應按照第5.2.4條表5.2.4注3的規(guī)定,降低屋面、外墻的傳熱系數(shù)。5.2.10建筑圍護結(jié)構設計文件編制深度,應符合本標準附錄F的規(guī)定。6 采暖、通風和空氣調(diào)節(jié)節(jié)能設計6.1 一般規(guī)定6.1.1采用集中采暖、集中空調(diào)系統(tǒng)和戶式中央空調(diào)系統(tǒng)時,在施工
22、圖設計階段,應進行熱負荷和逐項逐時的冷負荷計算。6.1.2應預留設置采暖或空調(diào)設施的位置和條件;有條件時,宜設置采暖或空調(diào)設施。6.1.3 采暖、空調(diào)方式的選擇,應根據(jù)建筑規(guī)模和使用特征,結(jié)合當?shù)啬茉?、環(huán)境保護、投資條件及運行費用,經(jīng)技術經(jīng)濟分析綜合論證后確定。采用集中采暖、集中空調(diào)系統(tǒng)時,應優(yōu)先采用可再生能源、余熱、廢熱供冷供熱技術。6.1.4不應采用直接電熱采暖設備或裝置;電熱鍋爐、電熱水器作為采暖和空調(diào)系統(tǒng)的熱源。6.1.5采用集中采暖、空氣調(diào)節(jié)系統(tǒng)時,應設計分室溫度控制及分戶熱(冷)量計量裝置。6.2 采暖6.2.1采暖系統(tǒng)應采用熱水作為熱媒。6.2.2集中采暖系統(tǒng),采用散熱器采暖時,
23、供水溫度不應超過95,供回水溫差不應小于20;采用低溫熱水地板輻射采暖時,供水溫度不應超過60,供回水溫差不宜小于10。地板輻射采暖樓(地)面結(jié)構應采用熱惰性小的構造做法,相鄰熱水輻射管之間的輻射空間不得填灌混凝土,熱水輻射管底面的保溫聚苯板(密度30kg/m3)厚度不得小于30mm,熱水輻射管空間上部的樓(地)面層的熱阻不得大于0.15m2K/W。6.2.3室內(nèi)采暖系統(tǒng)所采用的制式應能保證進行分室溫度調(diào)節(jié)。6.2.4采用散熱器采暖時,每組散熱器進水管上應安裝溫度調(diào)節(jié)閥,且宜安裝恒溫控制閥。6.2.5散熱器宜明裝,散熱器外表面應刷非金屬涂料。6.2.6散熱器的散熱面積,應根據(jù)熱負荷計算確定。6
24、.2.7集中采暖系統(tǒng)供水或回水管的分支管路上,應根據(jù)水力平衡要求設置水力平衡裝置。6.2.8在施工圖設計階段,應對室內(nèi)采暖系統(tǒng)進行詳細的水力平衡計算,除共有部分外,各并環(huán)路間的阻力差額不應大于15%。6.2.9在施工圖設計階段,應對室外管網(wǎng)進行詳細的水力平衡計算,當室外管網(wǎng)水力平衡計算達不到平衡要求時,應在建筑物熱力入口處設置水力平衡裝置。6.2.10集中采暖系統(tǒng)熱水循環(huán)水泵的耗電輸熱比(EHR)值應符合下式要求:EHR=N/Q(6.2.10-1)EHR0.0056(14+L)/t(6.2.10-2)式中: N 水泵在設計工況點的軸功率,kW;Q建筑供熱負荷,kW;電機和傳動部分的效率。采用直
25、聯(lián)方式時,=0.85;采用聯(lián)軸器連接方式時,=0.83;t設計供回水溫度差,oC。系統(tǒng)中管道全部采用鋼管連接時:取t=25 oC;系統(tǒng)中管道部分采用塑料管材連接時,取t =20 oC;L室外主干線(包括供回水管)總長度,m。當L500m時,= 0.0115;當500L7100W)能效比類型能效比(W/W)風冷式不接風管2.80接風管2.50水冷式不接風管3.20接風管2.906.4.4當采用蒸汽、熱水型溴化鋰吸收式冷水機組及直燃型溴化鋰吸收式冷(溫)水機組作為集中式空氣調(diào)節(jié)系統(tǒng)的冷熱源設備時,其性能系數(shù)不應低于表6.4.4的規(guī)定值。表6.4.4 溴化鋰吸收式機組性能參數(shù)機型名義工況性能參數(shù)冷(
26、溫)水進/出口溫度()冷卻水進/出口溫度()蒸汽壓力(MPa)單位制冷量蒸汽耗量kg/(kWh)性能系數(shù)(W/W)制冷供熱蒸汽雙效18/1330/350.251.4012/70.40.61.310.81.28直燃供冷12/730/351.20供熱出口600.90注:直燃機的性能系數(shù)為:制冷量(供熱量)/加熱源消耗量(以低位熱值計)電力消耗量(折算成一次能)。6.4.5當采用房間空調(diào)器(熱泵型)作為房間空氣調(diào)節(jié)系統(tǒng)的冷熱源設備時,其能效比不應低于表6.4.5的規(guī)定值。表6.4.5 房間空調(diào)器能效比類型額定制冷量(CC)/ W能效比(W/W)分體式CC45003204500CC7100310710
27、0CC140003006.4.6當采用轉(zhuǎn)速可控型空調(diào)器作為房間空氣調(diào)節(jié)系統(tǒng)的冷熱源設備時,宜選用符合轉(zhuǎn)速可控型空氣調(diào)節(jié)器能效限定值及能源效率等級(GB21455)中規(guī)定的2級產(chǎn)品,不應采用能效等級低于3級的產(chǎn)品。6.4.7當采用多聯(lián)式空調(diào)(熱泵)機組時,其性能系數(shù)不應低于多聯(lián)式空調(diào)(熱泵)機組能效限定值及能源效率等級(GB21454)中規(guī)定的3級。6.4.8當采用燃氣取暖器進行采暖、空調(diào)時,燃氣取暖器的熱效率不應小于表6.4.8的規(guī)定值。表6.4.8燃氣取暖器熱效率燃氣取暖器類型熱效率()家用燃氣取暖器84家用燃氣快速熱水器88常壓容積式燃氣熱水器88(以高熱值計算)燃氣熱水鍋爐896.4.9
28、當采用地下水式水源熱泵作為空調(diào)(熱泵)機組的冷熱源時,應根據(jù)水文地質(zhì)勘察資料進行熱源井設計。應確保地下水式水源熱泵系統(tǒng)有可靠的回灌措施,并不得對地下水資源造成浪費及污染。7 照明節(jié)能設計7.0.1每戶照明功率密度不宜大于6W/m2,不應大于7W/m2,房間的照度值不宜大于建筑照明設計標準GB50034-2004第6.1.1條的規(guī)定。7.0.2房間和公用區(qū)(樓梯及電梯間、走廊、門廳等)的照明標準值,應符合GB500342004第5.1.1條、第5.4.1條的規(guī)定。起居室、書房、臥室、廚房及衛(wèi)生間應按一般活動區(qū)和書寫閱讀、床頭閱讀、操作臺、洗臉化妝區(qū)分區(qū)采用混合照明方式。7.0.3房間照明光源應采
29、用三基色等細管徑熒光燈,不應采用普通照明白熾燈;開關頻繁的公用區(qū)宜采用白熾燈。7.0.4應采用開敞式、透明保護罩式及高反射比(拋光鋁面、鏡面、高白度光亮涂層)反射罩的節(jié)能型照明燈具,燈具效率不應低于65%。應采用高頻電子鎮(zhèn)流器或節(jié)能型電感鎮(zhèn)流器。在不低于允許安裝高度的條件下,應盡量降低燈具的安裝高度。7.0.5照明配電干線和分支線,應采用銅芯絕緣電線或電纜,分支線截面面積不應小于1.5mm2。7.0.6公用區(qū)應采用智能控制(光控、聲控、時控)節(jié)能型開關或裝置。8太陽能熱水系統(tǒng)與建筑一體化節(jié)能設計8.0.112層及12層以下建筑,宜做太陽能熱水系統(tǒng)與建筑的一體化節(jié)能設計。8.0.27至12層建筑
30、應采用集中供熱水系統(tǒng);4至6層建筑應采用集中分散供熱水系統(tǒng)或集中供熱水系統(tǒng);3層及3層以下建筑宜采用分散供熱水系統(tǒng)或集中分散供熱水系統(tǒng)。8.0.3太陽能熱水系統(tǒng)應設置輔助能源加熱設備。輔助能源應采用燃氣、工業(yè)(含發(fā)電廠)余熱及廢熱、熱電廠專供熱水或蒸汽、空氣源熱泵熱水器等,不得采用直接電加熱設備。8.0.4 太陽能集熱器宜設置在東、南、西向1800范圍內(nèi),太陽高度角不大于20.50時無直射陽光遮擋環(huán)境條件的屋面(或屋面架空支架)上,保證集熱器在“冬至”日有如表8.0.4所列不少于6小時、“夏至”日有不少于10小時的日照時間。表8.0.4 太陽位置(高度角h,方位角A)參數(shù)城市圈經(jīng)、緯度范圍季節(jié)
31、太陽位置時間(當?shù)靥枙r)12時11時或13時10時或14時9時或15時8時或16時7時或17時6時或18時北緯29.833(咸寧)30.925(孝感)東經(jīng)115.039(黃石)112.894(潛江)冬至h范圍值36.72035.62034.8033.76029.42028.49021.39020.61011.53010.8900.46000平均值36.17034.28028.96021.0011.2100.2100A范圍值016.81016.59031.78031.46044.16043.87054.18054.01062.40062.39069.38069.590平均值016.7031.6
32、244.0254.0962.3969.48大寒(小雪)h范圍值39.940 38.84037.89036.85032.2031.29023.8023.05013.59012.9902.2101.7500平均值39.39037.3731.7523.4213.291.980A范圍值017.92017.67033.67033.3046.48046.14056.72056.51065.1065.06072.27072.460平均值017.79033.48046.31056.61065.08072.360春分(秋分)h范圍值60.1059.0056.86055.89048.65047.93037.790
33、37.3025.67025.36012.94012.7900平均值59.5556.3848.2937.5525.5112.870A范圍值028.26027.49049.18048.26063.48062.73073.91073.41082.35082.1089.940.平均值027.8748.7263.1173.6682.2289.94夏至h范圍值83.62082.52075.17074.73062.52062.38049.53049.55036.58036.73023.82024.09011.42011.80平均值83.07074.96062.46049.54036.65023.96011.
34、610A范圍值068.06064.35083.78081.7091.99090.71098.38097.570104.370103.90110.620110.410平均值066.18082.73091.35097.980104.140110.520大暑(小滿)h范圍值80.4079.3073.39072.78061.27061.02048.38048.32035.38035.46022.5022.7109.91010.240平均值79.85073.09061.15048.35035.42022.61010.070A范圍值058.14055.14077.47075.54087.4086.1809
35、4.68093.910101.180100.730107.730107.540平均值056.62076.5086.79094.30100.960107.640注:1 表中h為太陽高度角(直射陽光與水平面的夾角),A為太陽方位角(直射陽光水平投射與正南方向的夾角)。2 表中范圍值的前一數(shù)字為咸寧、后一數(shù)字為孝感的值。3 太陽方位角(直射陽光水平投射與正南方向的夾角)A=0時為正南向;A=900時為正東向(早晨)或正西向(下午);A900時為東偏北向(早晨)或西偏北向(下午)。4 表中的時間、h、A值相鄰之間的值,可近似用插值法求取。條文說明為使太陽能資源利用率達到最大化,使集熱器獲取較多的太陽輻
36、射熱量,本條文規(guī)定應保證集熱器在“冬至”日有不少于6小時的日照時間。因此規(guī)定當太陽高度角不大于20.50時在東、南、西向1800范圍內(nèi)不得有遮擋直射陽光的障礙物(包括本建筑和相鄰建筑)。當正好符合此規(guī)定時:則太陽集熱器在“冬至”日有6小時的日照時間(9時至15時按孝感緯度計算,下同);在“大寒”日有6.56小時的日照時間(8時43分至15時17分);在“春分”或“秋分”日有8.8小時的日照時間(7時36分至16時24分);在日照時間最長的“夏至”日有10.57小時的日照時間(6時43分至17時17分);在冬季平均可獲取水平面上太陽總輻射照度日總量約83的份額,在夏季平均可獲取水平面上太陽總輻射
37、照度日總量約94的份額。 當南向有遮擋直射陽光的障礙物(如高層建筑物),不能滿足此條文時,則喪失了設置太陽能熱水系統(tǒng)的基本條件。為此,在小區(qū)規(guī)劃時,由南至北應依次布置低層、多層、小高層、高層建筑。武漢市氣象資料統(tǒng)計計算結(jié)果表明: 夏季水平面上的平均太陽總輻射照度日總量,是南向墻面上有日照時間內(nèi)太陽總輻射照度日總量的3.01倍,是東或西向墻面上有日照時間內(nèi)太陽總輻射照度日總量(不含無日照時間內(nèi)的散射照度)的1.96倍; 冬季水平面的平均太陽總輻射照度日總量,是南向墻面上太陽總輻射照度日總量的1.07倍,是東或西向墻面上有日照時間內(nèi)太陽總輻射照度日總量的2.65倍; 夏季水平面的平均太陽總輻射照度
38、日總量,是冬季水平面上的平均太陽總輻射照度日總量的3.1倍。同時,考慮到墻面上有相鄰建筑的相互陽光遮擋、建筑立面美觀等因素,因此本條文規(guī)定宜將太陽能集熱器設置在屋面上(不宜在墻面上設置)。當在東、西、北向坡屋面及有樓梯間、電梯機房的平屋面上設置太陽能集熱器時,宜采用架空支架設置方式,使其具有本條文規(guī)定的環(huán)境條件。8.0.5 太陽能集熱器平面宜面對正南向,集熱器傾角宜按表8.0.5選取。表8.0.5 太陽能集熱器的適宜傾角太陽能集熱器傾角季節(jié)夏至大暑(小滿)春分(秋分)大寒(小雪)冬至傾角可調(diào)型8o20o35o55o58o傾角固定型20 o35 o(按側(cè)重供春秋或夏季熱水要求選擇)陣列組合型10
39、 o25 o(按側(cè)重供春秋或夏季熱水要求選擇)注:表中傾角90o10至14時的太陽高度角平均值。陣列組合型按計算值減小100。8.0.6 太陽能集熱器的布置,應便于太陽能熱水系統(tǒng)的安裝、維護保養(yǎng)、檢修和屋面的翻修及清掃積雪。集熱器之間不得相互遮擋日照。8.0.7 太陽能集熱器應安裝在混凝土或型鋼專用支座(或支架)上,不得在成品屋面上直接安裝集熱器,安裝用錨固螺栓不得破壞屋面防水層和保溫層。太陽能集熱器支座(含支架)應根據(jù)建設方選定產(chǎn)品的安裝尺寸設計。支座應與屋面結(jié)構直接連接。支座周邊和頂面應設置防水層和保溫層,保溫層宜采用x400 x500型擠塑聚苯板等高強度保溫材料及加強型保護面層, 支座處
40、屋面的傳熱系數(shù)應符合本標準第5.2.4條表5.2.4的相關規(guī)定。集熱器與混凝土支座的連接,宜采用預埋螺栓或符合JGJ145-2004規(guī)定的后錨固方法。(此時,錨固螺栓可穿透防水層和保溫層,但應采用丙烯酸酯建筑密封膏或酮建筑密封膏做密封防水及防腐處理)。8.0.8設置有太陽能集熱的坡屋面,不應采用鋪瓦面層和外露防水卷材或涂膜防水層。8.0.9 太陽能熱水系統(tǒng)的管線應通過管道井或預埋防水套管進入室內(nèi)。管道井和套管應采取保溫斷熱處理措施,其傳熱系數(shù)應符合本標準第5.2.4條表5.2.4中屋面的相關規(guī)定。穿屋套管內(nèi)的空腔部分應滿灌發(fā)泡聚氨酯,套管頂部應采用硅酮建筑密封膏或聚氨酯建筑密封膏等做防水封閉處
41、理。8.0.10熱水或熱媒管道應做外保溫,冷水管道應做防凍保溫,保溫層厚度應通過計算確定。8.0.11太陽能熱水系統(tǒng)的設計,還應符合民用建筑太陽能熱水系統(tǒng)應用技術規(guī)范GB50364-2005的其它規(guī)定。8.0.12 太陽能集熱系統(tǒng)(含支座或支架)應在建筑平面、立面及效果圖上繪出。太陽能集熱系統(tǒng)與建筑立面應協(xié)調(diào)統(tǒng)一,和諧美觀。(規(guī)范性附錄)外墻平均傳熱系數(shù)與平均熱惰性指標的計算A.0.1單一朝向外墻的平均傳熱系數(shù)Kmi與平均熱惰性指標Dmi應按下式(A.0.11、A.0.12)計算:(A.0.11)(A.0.12)式中: Kmi、Dmi單一朝向外墻的平均傳熱系數(shù)W /(m2K)、平均熱惰性指標值
42、;KP、Dp單一朝向外墻主體部位的傳熱系數(shù)W /(m2K) 、熱惰性指標值,應按民用建筑熱工設計規(guī)范GB50176-93和本附錄的規(guī)定計算;KB1、KB2、KBn、DB1、DB2、DBn單一朝向外墻各熱橋部位的傳熱系數(shù)W /(m2K) 與熱惰性指標值。應按民用建筑熱工設計規(guī)范GB50176-93和本附錄的規(guī)定計算;FP,F(xiàn)B1、FB2、FBn外墻主體部位與各熱橋部位的面積(m2)。應按外墻或內(nèi)墻面上的墻面面積計算。其中與外墻銜接的構件(如室外陽臺梁板、陽臺欄板及隔板、挑檐及天溝梁板、雨篷梁板、空調(diào)室外機擱板等,室內(nèi)樓板及樓梯板、各種梁、內(nèi)墻及柱等)的面積,應按其與外墻銜接面的面積計算。外墻主體
43、部位和各熱橋部位如圖A.0.1-1、圖A.0.1-2所示。圖A.0.1-1 外墻主體部位及熱橋部位示意圖圖A.0.1-2 外墻凸窗熱橋部位示意圖A.0.2單一朝向外墻上的外凸和內(nèi)凹側(cè)向外墻,架空部位(含過街通道、架空風道)和上部凹陷部分的側(cè)向外墻,不分朝向,應分別計算其Kmi、Dmi值(此處i為軸線編號)。其中,架空部位的側(cè)向外墻不計算Dmi值,并認定其符合本標準的規(guī)定。A.0.3外墻平均傳熱系數(shù)計算,應包含外墻上的下列主體部分和全部熱橋部位。1 外墻主體部位包括砌體結(jié)構的砌體墻,框架結(jié)構的砌體填充墻,剪力墻結(jié)構的混凝土墻,框架剪力墻等結(jié)構中占外墻面積比例最大的砌體填充墻或混凝土剪力墻。2 外
44、保溫外墻的熱橋部位包括:有外保溫層的混凝土梁(含圈梁、門窗過梁、窗臺板、雨篷梁等)、柱(含構造柱)、剪力墻、凸窗頂板與底板及側(cè)墻板、其他采用外保溫將外露面全部包裹斷熱處理的墻外構件(如挑檐及天溝梁板、空調(diào)室外機擱板、耳條及裝飾條板等);無外保溫層的陽臺梁和樓板、陽臺欄板及隔板、雨篷梁板、挑檐及天溝梁板、裝飾架梁板等外挑構件,以及非透明幕墻的懸挑或貼墻金屬構件等。3 內(nèi)保溫外墻的熱橋部位包括:有內(nèi)保溫層(即外墻內(nèi)墻面臨空)部分的混凝土梁(含圈梁、門窗過梁、窗臺板等)、柱(含構造柱)、剪力墻,以及有外保溫層的凸窗頂板與底板及側(cè)墻板等;無內(nèi)保溫層(即與外墻內(nèi)墻面連接)部分的內(nèi)梁、內(nèi)墻、樓板、屋面板、
45、樓梯梁板、與內(nèi)墻連接的柱(含構造柱)等。A.0.4外保溫外墻系統(tǒng)各種熱橋部位可歸納簡化為圖A.0.41、圖A.0.42所示有外保溫層熱橋和無外保溫層熱橋兩種類型,應分別計算其傳熱系數(shù)與熱惰性指標值。1 有外保溫層熱橋部位(A.0.41)(A.0.42)圖A.0.41有外保溫層熱橋示意圖圖A.0.42無外保溫層熱橋板部位示意圖2 無外保溫層熱橋部位(金屬構件另行計算)(A.0.43)(A.0.44)式中:有外保溫層熱橋部位的傳熱系數(shù)(W / m2K);無外保溫層熱橋部位的傳熱系數(shù)(W / m2K);有外保溫層熱橋部位的熱惰性指標;無外保溫層熱橋部位的熱惰性指標;外保溫墻面的熱惰性指標;內(nèi)表面換熱
46、阻(m2K/W),Ri=1/i=1/8.7;外表面換熱阻(m2K/W),Re=1/e,外表面換熱系數(shù)取冬季和夏季中的較小值23(m2K/W);包括保溫層、保護層、墻面粉刷層在內(nèi)的外保溫墻面的熱阻值(m2K / W);內(nèi)墻面粉刷層的厚度(m);混凝土梁、柱、墻的厚度(m),當其厚度大于外墻厚度時,取外墻的厚度;包括保溫層、保護層、墻面粉刷層在內(nèi)外保溫墻面的總厚度(m);3 無外保溫熱橋部位的面積,應包括單一朝向外墻上全部無保溫層的外凸和外挑構件與外墻連接的截面面積。有外保溫層熱橋部位的面積,應包括單一朝向外墻上全部有外保溫梁、柱、剪力墻的面積,并減去與梁、柱、剪力墻連接的無外保溫熱橋構件的全部面
47、積。A.0.5內(nèi)保溫外墻系統(tǒng)各種熱橋部位,可歸納簡化為如圖A.0.51、圖A.0.52所示有內(nèi)保溫層熱橋和無內(nèi)保溫層熱橋兩種類型,應分別計算其傳熱系數(shù)與熱惰性指標值。1 有內(nèi)保溫層熱橋部位(A.0.51)(A.0.51)圖A.0.51 有內(nèi)保溫層熱橋示意圖圖A.0.52 無內(nèi)保溫層熱橋板部位示意圖2 無內(nèi)保溫層熱橋部位式中:有內(nèi)保溫層熱橋部位的傳熱系數(shù)(W / m2K);無內(nèi)保溫層熱橋部位的傳熱系數(shù)(W / m2K);有內(nèi)保層熱橋部位的熱惰性指標;無內(nèi)保溫層熱橋部位的熱惰性指標;內(nèi)保溫墻面的熱惰性指標;包括保溫層、保護層、墻面粉刷層在內(nèi)的內(nèi)保溫墻面的熱阻值(m2K / W);外墻面粉刷層的厚度
48、(m);包括保溫層、保護層、墻面粉刷層在內(nèi)的內(nèi)墻面的總厚度(m);外墻面粉刷層材料的導熱系數(shù)(W / mK);內(nèi)墻面粉刷層材料的導熱系數(shù)(W / mK);外墻面粉刷層材料的蓄熱系數(shù)(W / m2K)。3 無內(nèi)保溫層熱橋部位的面積,應包括單一朝向外墻上全部無內(nèi)保溫層的內(nèi)接梁、板、柱、墻等部位的銜接面積。有內(nèi)保溫層熱橋部位的面積,應包括單一朝向外墻上全部梁、柱、剪力墻的面積,并減去無內(nèi)保溫層熱橋部位的面積。A.0.6外墻的熱工性能計算參數(shù),應按表A.0.6中所列數(shù)值采用。序號材料名稱導熱系數(shù)W/(mK)蓄熱系數(shù)SW/(K)干密度(/m3)比熱容ckJ/(kgK)修正系數(shù)a備注1墻體1.1燒結(jié)頁巖磚
49、墻(含燒結(jié)粘土磚墻)0.8110.6318001.051.00自然含濕狀態(tài)1.2粉煤灰磚墻0.8711.1118001.051.00自然含濕狀態(tài)1.3蒸壓灰砂磚墻1.1012.7219001.051.00自然含濕狀態(tài)1.4KP1型燒結(jié)多孔磚墻0.587.9214001.051.00自然含濕狀態(tài)1.5混凝土多孔磚墻1.0010.5116500.921.00自然含濕狀態(tài)1.6普通混凝土小型空心砌塊混凝土墻1.6.1混凝土部分1.5115.3623000.921.001.6.2鋼筋混凝土抗震芯柱部分1.7417.2025000.921.001.7加氣混凝土砌塊填充墻1.7.1Mb5.0專用砌筑砂漿砌
50、加氣混凝土砌塊填充墻B05級0.2493.506501.051.00表中值含砌筑砂漿,自然含濕1.7.2B06級0.2633.857401.051.001.7.3B07級0.2774.218501.051.001.7.4B08級0.2954.589501.051.001.7.5砌塊專用保溫砌筑砂漿砌加氣混凝土砌塊填充墻B05級0.1962.895751.051.001.7.6B06級0.2103.236651.051.001.7.7B07級0.2233.607751.051.001.7.8B08級0.2423.978751.051.001.8鋼筋混凝土1.7417.2025000.921.00
51、自然含濕狀態(tài)表A.0.6墻體及主要建筑材料熱工性能計算參數(shù)續(xù)表A.0.62保溫隔熱材料2.1絕熱用模塑聚苯乙烯泡沫塑料板0.041(干燥)0.2918221.381.20打磨壓縮及塑料錨栓等影響2.2膠粉聚苯顆粒漿料(干燥)0.0590.952501.171.25自然含濕及塑料錨栓等影響2.3泡沫玻璃0.064(干燥)0.791600.841.20吸濕影響0.066(干燥)0.851802.4絕熱用擠塑聚苯乙烯泡沫塑料板(局部熱橋處理部位采用)0.030(干燥)0.29251.381.20打磨壓縮及塑料錨栓等影響2.5噴涂硬質(zhì)聚氨酯塑料(局部熱橋處理部位采用)0.030(陳化90天后,35測試
52、條件、干燥)0.30301.381.20打磨壓縮及塑料錨栓等影響3其它材料3.1面磚1.1012.7220001.051.00自然含濕狀態(tài)3.2石灰砂漿0.8110.0716001.051.00自然含濕狀態(tài)3.3水泥石灰砂漿0.8710.7517001.051.00自然含濕狀態(tài)3.4水泥砂漿0.9311.3718001.051.00自然含濕狀態(tài)3.5粉刷石膏砂漿0.769.4415001.051.00自然含濕狀態(tài)3.6纖維增強石膏板0.305.1311501.051.103.7加氣混凝土砌塊墻專用保溫砌筑砂漿0.20(干燥)3.698001.171.30吸濕影響3.8加氣混凝土砌塊墻專用保溫抹
53、灰砂漿0.20(干燥)3.698001.171.30注:加氣混泥土砌塊磚填充墻的表中參數(shù)值,按600(長)250(高)砌塊、水平灰縫厚度15mm、豎向灰縫厚度20mm計算。砌筑施工應采用300高主體砌塊(250及200高砌塊僅作為調(diào)整墻高用),水平灰縫厚度宜10mm。(規(guī)范性附錄)建筑物體形系數(shù)和窗墻面積比的計算B.0.1建筑物體型系數(shù)(S),應按建筑物與室外大氣接觸的外表面積(F)與建筑體積(V)的比值計算,即S=F/V。B.0.2建筑外表面積(F),應按屋頂表面積(FR)、外墻表面積(FW)、底面接觸室外空氣的架空或外挑樓板表面積(FB)的總和計算,即F= FR+FW+FBB.0.3屋頂表
54、面積(FR)應按下列規(guī)定計算:1 平屋頂面積,應按支承屋頂?shù)耐鈮ν獍€圍成的面積計算。不采暖空調(diào)樓梯間與電梯機房的表面積,應按出屋外包線圍成的面積計算(即不考慮出屋面電梯機房的挑出部分);2 居住空間上的坡屋頂與不住人閣樓上的保溫隔熱坡屋頂?shù)谋砻娣e,應按支承斜坡屋面的外墻外包線圍成的坡屋頂?shù)耐獗砻娣e計算;當保溫屋面設置在不住人的閣樓樓板上面時,應按閣樓平屋頂表面積計算;3 與房間直接連通的封閉陽臺的屋頂表面積,應計入屋頂總面積中。B.0.4外墻表面積(FW)應按下列規(guī)定計算;1 外墻表面積應按不同朝向(FW.i,i為E、W、S、N、)分別計算。單一朝向外墻的表面積,應包括該朝向外墻上的墻體(含
55、砌體和墻中的全部混凝土構件)、外門(含單元門、陽臺門及門芯板)外窗、凸出外墻面的凸窗(頂板、底板、側(cè)窗或側(cè)墻板)等部分的總面積;2 單一朝向外墻的表面積,應按該朝向各分段外墻外包長度(L)與各分段外墻對應高度(H)的乘積的總和計算。其中,外墻高度應按如下規(guī)定計算:(1)觸土地面、架空地面、不采暖空調(diào)地下室或半地下室地(樓)面之上的外墻,取地(樓)面標高至屋面板檐口標高的高度;(2)架空或外挑樓板下部的外墻,取地(樓)面標高至架空或外挑樓板樓面標高的高度;(3)架空或外挑樓板上部的外墻,取架空或外挑樓板樓面標高至屋面板檐口標高的高度;3 凸窗的表面積,應按凸出外墻墻面的凸窗頂板、底板、側(cè)窗或側(cè)墻
56、板的外包表面積之和計算;4 與房間直接連通的封閉陽臺,周邊外墻(含窗)的表面積應計入外墻的表面積中;5 下列部位外墻不參與外墻表面積的計算:(1)凸出屋面的不采暖空調(diào)樓梯間、電梯機房及管道井的外墻(即屋面標高以上部分);(2)保溫屋面設置在閣樓樓板上的閣樓外墻(閣樓樓面以標高上部分);(3)當封閉陽臺與連通房間之間設置有符合本標準第5.2節(jié)規(guī)定的門(含門芯板)、窗、外墻時,封閉陽臺上凸出外墻面的封閉陽臺外墻(含窗);(4)架空層(含架空車庫、結(jié)構轉(zhuǎn)換層、設備層)中無相鄰居住空間的不采暖空調(diào)獨立樓梯間、電梯間、管道井的外墻、井壁(架空層上下樓地面標高之間部分);(5)不采暖空調(diào)半地下室的外墻(樓
57、地面標高以下部分);(6)凸出相鄰最外外墻面的不采暖空調(diào)樓梯間、電梯間、管道井的側(cè)向外墻(即此處外墻按最外外墻面計算);(7)與相鄰建筑銜接部分的外墻。B.0.5底層接觸室外空氣的架空或外挑樓板的表面積(FB),應按如下規(guī)定計算:1 架空或外挑樓板的表面積,應按支承樓板的外墻外包線圍成的面積計算;2 當封閉陽臺與連通房間之間設置有符合本標準第5.2節(jié)規(guī)定的門(含門芯板)、窗、外墻時,底面接觸室外空氣的陽臺樓板不參與架空或外挑樓板表面積的計算;3 傳熱系數(shù)K0.65 W/(m2K)的架空或外挑樓板,不參與架空或外挑樓板表面積的計算;B.0.6建筑體積(V)應按以下規(guī)定計算:1 建筑體積應按建筑物
58、外表面和底層地面(含底面接觸室外空氣的架空或外挑樓板的樓面、不采暖空調(diào)地下室、半地下室上部的樓地面)圍成的體積計算;2 保溫隔熱坡屋頂?shù)撞块w樓的體積,應按斜坡屋面板板面、閣樓外墻外表面與閣樓樓板面圍成的體積計算;3 凸窗的體積,應按各朝向外墻上全部凸窗體積之和計算。單個凸窗的體積,應按該凸窗的頂板、底板、側(cè)向窗或側(cè)墻板外表面圍成的面積與外墻面至凸窗正面窗外表面寬度尺寸的乘積計算;4 計算建筑體積時,與相鄰建筑銜接的墻體按外墻考慮;5 下列建筑空間不參與建筑體積的計算:(1)凸出屋面的不采暖空調(diào)樓梯間、電梯機房及管道井的外墻(該處屋面板樓面以上部分);(2)保溫屋面設置在不住人閣樓樓板上的閣樓空
59、間(閣樓板面標高以上部分);(3)當封閉陽臺與連通房間之間設置有符合本標準第5.2節(jié)規(guī)定的門(含門芯板)、窗、外墻時,凸出外墻面的封閉陽臺空間;(4)架空層(含架空車庫、結(jié)構轉(zhuǎn)換層、設備層)中無相鄰居住空間的不采暖空調(diào)獨立樓梯間、電梯間、管道井的外墻、井壁(架空層上下樓地面標高之間部分);(5)不采暖空調(diào)半地下室的空間(樓地面標高以下部分);(6)凸出相鄰最外外墻面的不采暖空調(diào)樓梯間、電梯間、管道井的空間。B.0.7窗墻面積比應按下列規(guī)定計算:1 窗墻面積比(wdw)應按單個房間的窗(含陽臺門透明部分)洞口面積(FGi)與房間立面單元面積(FWi)的比值計算,房間立面單元面積應按房間層高(Hi
60、)與開間寬度(Bi)的乘積計算,即wdw = FGi/ FWi= FGi/(HiBi);2 窗墻面積比也可按每戶同一朝向居室(包括客廳、餐廳、臥室、書房,不包括廚房、衛(wèi)生間、儲藏室、樓梯電梯間)的單朝向窗墻面積比計算,即wdw.i(i為E、W、S、N、)=(FG1 + FG2 + FG3)/(H1B1 + H2B2 + H3B3),當層高相同時,wdw.i(i為E、W、S、N、)=(FG1 + FG2 + FG3)/(B1 + B2 + B3)H;3 當一個房間同時在開間立面單元相鄰外墻上設置外窗時,應將全部外窗匯總到開間立面單元計算其窗墻面積比;4 有側(cè)向窗的凸窗窗洞口面積(FGi),應按外
溫馨提示
- 1. 本站所有資源如無特殊說明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請下載最新的WinRAR軟件解壓。
- 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請聯(lián)系上傳者。文件的所有權益歸上傳用戶所有。
- 3. 本站RAR壓縮包中若帶圖紙,網(wǎng)頁內(nèi)容里面會有圖紙預覽,若沒有圖紙預覽就沒有圖紙。
- 4. 未經(jīng)權益所有人同意不得將文件中的內(nèi)容挪作商業(yè)或盈利用途。
- 5. 人人文庫網(wǎng)僅提供信息存儲空間,僅對用戶上傳內(nèi)容的表現(xiàn)方式做保護處理,對用戶上傳分享的文檔內(nèi)容本身不做任何修改或編輯,并不能對任何下載內(nèi)容負責。
- 6. 下載文件中如有侵權或不適當內(nèi)容,請與我們聯(lián)系,我們立即糾正。
- 7. 本站不保證下載資源的準確性、安全性和完整性, 同時也不承擔用戶因使用這些下載資源對自己和他人造成任何形式的傷害或損失。
最新文檔
- 2025水泥供貨合同模板
- 2025鋁材采購合同書樣本
- 2025年光伏支架鋼結(jié)構加工合同
- 2025年招投標與合同管理:合同風險控制案例分析
- 2025學校翻新教學樓合同書
- 2025標準集體土地使用權轉(zhuǎn)讓合同
- 2025年度工程承包合同簽訂年度
- 《2025版權授權合同模板》
- 2025玉米買賣合同模板
- 《守護健康熱愛生命》課件
- 養(yǎng)老院火災事故防范重點培訓課件
- 便秘的評估與護理
- 人才招聘中的社交媒體運用與效果評估
- 2025就業(yè)指導課件
- 2025-2030中國菊粉行業(yè)市場發(fā)展趨勢與前景展望戰(zhàn)略研究報告
- 新能源電池材料回收行業(yè)深度調(diào)研及發(fā)展戰(zhàn)略咨詢報告
- 高校實驗室安全基礎
- 教師綜合考核獎勵方案
- 專題18 電磁感應綜合題(解析版)-2025年高考物理二輪熱點題型歸納與變式演練(新高考)
- 北京海淀區(qū)2023-2024學年八年級下學期期中考試物理試題(原卷版)
- 《紡織品跟單復習》課件
評論
0/150
提交評論