




版權說明:本文檔由用戶提供并上傳,收益歸屬內容提供方,若內容存在侵權,請進行舉報或認領
文檔簡介
CarotidWALLSTENTTM
頸動脈支架?支架自膨支架Elgiloy?
金屬絲編制管狀網眼結構2支架輸送系統Monorail?導管設計,0.014“導絲輸送系統;5F(6&8mm)和6F(10mm)低外廓,高柔順性;
CarotidWALLSTENTTM
頸動脈支架閉環設計跟蹤性極佳的SDS-支架輸送系統卓越的顯影性獨特的可回收能力*
唯一經FDA批準可用于雙側治療頸動脈支架**臨床數據支持*Pleasenotethatreconstrainmentandrepositioningaresubjecttospecificlimitations.PleaserefertoDFUcautionsandwarningsforadditionalinformation.**TheCarotidWALLSTENTEndoprosthesisisindicatedforuseineligiblepatientswithipsilateralorbilateralcarotidarterydiseaseCarotidWALLSTENTTM
頸動脈支架閉環單元結構,獨特的支架設計提供最大化的斑塊覆蓋高度的柔順性便于使用的輸送系統*FreeCellArea:Measurestheaveragearea(mm2)withintheperimeterofconnectingstruts.Smallernumber=smallerfreecellarea.CarotidWALLSTENTTM
頸動脈支架支架設計-閉環
Vs.開環閉環支架設計CarotidWALLSTENT?EndoprosthesisXact?CarotidStent開環支架設計Precise?PRORx
NitinolStentSystemRXAcculink?CarotidStentCarotidWALLSTENTEndoprosthesisPrecisePRORxNitinolStentSystemRXAcculinkCarotidStentImagestakenbyandonfileatBSC.IllustrationsbyBSC.PreciseProisatrademarkofCordisCorporation,AcculinkisatrademarkofAbbottCardiovascularSystems,Inc,andXactistrademarkofMedNova,Ltd.閉環支架設計CWS與其他頸動脈支架相比,具有最小的支架網孔面積**CarotidWALLSTENT?
閉環設計提供最大化的斑塊覆蓋以及光滑平整的管腔
**TestingperformedonCarotidWALLSTENTEndoprosthesis8mmx21mm,PreciseProRX8mmx40mm,RXACCULINK7-10mmx40mm,Xact7-9mmx40mm.Benchtestresultsmaynotnecessarilybeindicativeofclinicalperformance.Testresultsshownareformodelsdeemedmosttypicallyselectedforplacementincommoncarotidarterywithareferencediameterof<8mm.Othermodelswerealsotestedandyieldedsimilarresults.N=3.Dataonfile.PreciseProisatrademarkofCordisCorporation,AcculinkisatrademarkofAbbottCardiovascularSystems,Inc,andXactistrademarkofMedNova,Ltd.*FreeCellArea:測量支架連接小桿周長間的平均面積數值越小=支架網孔面積越小PhotographstakenbyBostonScientificCorporation閉環支架設計CarotidWALLSTENT?
閉環設計提供最大化的斑塊覆蓋以及光滑平整的管腔
DoesCarotidStentDesignInfluenceOutcomes?
R.M.Bersin,CatheterizationandCardiovascularInterventions2008;72:863–866目前為止,已經完成3項有關頸動脈支架設計與臨床結果的回顧性、非隨機研究。DoesFreeCellAreaInfluencetheOutcomeinCarotidArteryStenting?Bosiersetal.Aretrospectiveanalysisof30dayoutcomesofacarotidarterystentingmulticenterdatabaseconsistingof3179consecutivepatientsSPACE,aretrospective,randomizedtrialofcarotidarterystentingversusendarterectomyinstandardsurgicalriskpatientswithsymptomaticcarotidarterystenosesSchillingerM,GschwendtnerM,ReimersB,etal.Doescarotidstentcelldesignmatter?Aretrospective,nonrandomizedreviewofacarotidarterystentingmulticenterdatabaseconsistingof1,684consecutivepatientsDoesCarotidStentDesignInfluenceOutcomes?
Bersin.CatheterizationandCardiovascularInterventions2008;72:863–866..DoesFreeCellAreaInfluencetheOutcomeinCarotidArteryStenting?
Bosiersetal.EurJVascEndovascSurg2007;33:135-141.目的:明確頸動脈支架設計,尤其是支架網孔面積,對于頸動脈支架術后30天卒中、死亡或TIA的影響。
30天結果的回顧性分析TIA,死亡,大和小卒中(非心肌梗死)共3179接受頸動脈支架手術的患者4個中心Bosiers,Deloose-BelgiumPeeters,Verbis-BelgiumSetacci,Donatoetal.-ItalyCremonesi,Castriota-ItalyDoesFreeCellAreaInfluencetheOutcomeinCarotidArteryStenting?Bosiersetal.EurJVascEndovascSurg2007;33:135-141.DoesFreeCellAreaInfluencetheOutcomein
CarotidArteryStenting?
Bosiersetal.EurJVascEndovascSurg2007;33:135-141.
閉環支架定義為支架網孔面積<5.0mm2例如CarotidWALLSTENT?EndoprosthesisXACT?Carotid
Stent開環支架定義為支架網孔面積>5.0mm2例如Precise?Rx
NitinolStentSystemRXAcculink?CarotidStentDoesFreeCellAreaInfluencetheOutcomeinCarotidArteryStenting?Bosiersetal.EurJVascEndovascSurg2007;33:135-141.PreciseisatrademarkofCordisCorporation,AcculinkisatrademarkofAbbottCardiovascularSystems,Inc,andXactistrademarkofMedNova,Ltd.第30天事件:閉環
vs.開環支架設計
TIA,死亡,大和小卒中DoesFreeCellAreaInfluencetheOutcomeinCarotidArteryStenting?Bosiersetal.EurJVascEndovascSurg2007;33:135-141.對于癥狀性患者,術后第30天的主要事件發生率差異顯著開環支架設計(7.0%)VS
閉環支架設計(2.2%)(p<0.0001)DoesFreeCellAreaInfluencetheOutcomein
CarotidArteryStenting?
Bosiersetal.EurJVascEndovascSurg2007;33:135-141.
N=3179P=0.005N=1317P<0.0001N=1862P=1.0DoesFreeCellAreaInfluencetheOutcomein
CarotidArteryStenting?
Bosiersetal.EurJVascEndovascSurg2007;33:135-141.
術后=(TIA,卒中,死亡)直到術后30天發生閉環
vs.開環支架設計DoesFreeCellAreaInfluencetheOutcomeinCarotidArteryStenting?Bosiersetal.EurJVascEndovascSurg2007;33:135-141.對于癥狀性患者,手術30天以后的主要事件發生率差異顯著開環支架設計(6.3%)VS閉環支架設計(1.3%)(p<0.0001)N=3179P<0.0001N=1317P<0.0001N=1862P=1.0患者評估由獨立神經病學醫師進行神經學上的局限性回顧性的研究非隨機設計可能導致在選擇時會因特定病變類型有所偏向注冊數據受制于自我審計技術復雜性沒有評估,結果沒有經過風險校正有必要進行前瞻性的隨機研究來比較不同支架網孔面積以得到最終結論DoesFreeCellAreaInfluencetheOutcomeinCarotidArteryStenting?Bosiersetal.EurJVascEndovascSurg2007;33:135-141.DoesFreeCellAreaInfluencetheOutcomein
CarotidArteryStenting?
Bosiersetal.EurJVascEndovascSurg2007;33:135-141.
總結四個中心的30天結果回顧性分析N=3179CASpatients對于癥狀性患者,術后第30天的主要事件發生率差異顯著,開環支架設計(7.0%)VS閉環支架設計(2.2%)(p<0.0001)對于癥狀性患者,手術30天以后的主要事件發生率差異顯著,開環支架設計(6.3%)VS閉環支架設計(1.3%)(p<0.0001)DoesFreeCellAreaInfluencetheOutcomeinCarotidArteryStenting?Bosiersetal.EurJVascEndovascSurg2007;33:135-141.DoesFreeCellAreaInfluencetheOutcomein
CarotidArteryStenting?
Bosiersetal.EurJVascEndovascSurg2007;33:135-141.
CarotidWALLSTENT?Endoprosthesis閉環設計跟蹤性極佳的SDS-支架輸送系統卓越的顯影性獨特的可回收能力*
唯一經FDA批準可用于雙側治療頸動脈支架**臨床數據支持*Pleasenotethatreconstrainmentandrepositioningaresubjecttospecificlimitations.PleaserefertoDFUcautionsandwarningsforadditionalinformation.**TheCarotidWALLSTENTEndoprosthesisisindicatedforuseineligiblepatientswithipsilateralorbilateralcarotidarterydisease跟蹤性極佳的SDS-支架輸送系統獨特的編織結構提高支架的柔順性CarotidWALLSTENT?具有高度柔順的輸送系統,提供卓越的跟蹤性以通過扭曲病變TestingperformedonCarotidWALLSTENTEndoprosthesis8mmx21mm,PreciseProRX8mmx40mm,RXACCULINK7-10mmx40mm,Xact7-9mmx40mm.Benchtestresultsmaynotnecessarilybeindicativeofclinicalperformance.Testresultsshownareformodelsdeemedmosttypicallyselectedforplacementincommoncarotidarterywithareferencediameterof<8mm.Othermodelswerealsotestedandyieldedsimilarresults.N=3.Dataonfile.PreciseProisatrademarkofCordisCorporation,AcculinkisatrademarkofAbbottCardiovascularSystems,Inc,andXactistrademarkofMedNova,Ltd.DeliveryForce:Benchtestthatmeasuresthemaximumforcerequiredtonavigatethroughabenchmodeloftortuosity.Smallervalues=Lessforcerequired低外廓的輸送系統直徑≤8mm直徑>8mmCarotidWALLSTENT?Endoprosthesis5F6FXact?CarotidStent6F6FRXAcculink?CarotidStent6F6FPrecise?PRORxNitinolStentSystem5F6F匹配的導引鞘*(VesselSize)*InformationexcerptedfromrespectiveDFUs.PreciseProisatrademarkofCordisCorporation,AcculinkisatrademarkofAbbottCardiovascularSystems,Inc,andXactistrademarkofMedNova,Ltd.低外廓設計允許其通過5For6F血管鞘
CarotidWALLSTENT?的低外廓支架輸送系統使其具有卓越的跟蹤性以通過迂曲的解剖結構便于使用Thepin-and-pulldeliverysystemisdesignedtosimplifydeliveryCarotidWALLSTENT?EndoprosthesisDeliverySystemFinalAssembly.ImagepropertyofBostonScientificCorporation.Notnecessarilytoscale.閉環設計跟蹤性極佳的SDS-支架輸送系統卓越的顯影性獨特的可回收能力*
唯一經FDA批準可用于雙側治療頸動脈支架**臨床數據支持*Pleasenotethatreconstrainmentandrepositioningaresubjecttospecificlimitations.PleaserefertoDFUcautionsandwarningsforadditionalinformation.**TheCarotidWALLSTENTEndoprosthesisisindicatedforuseineligiblepatientswithipsilateralorbilateralcarotidarterydiseaseCarotidWALLSTENTTM
頸動脈支架出色的顯影性在對比測試中,與其他頸動脈支架相比,CarotidWALLSTENT是顯影性最好的支架CarotidWALLSTENT?的設計使支架具有高度可視性,便于支架的精確釋放TestingperformedonCarotidWALLSTENTEndoprosthesis8mmx21mm,PreciseProRX8mmx40mm,RXACCULINK7-10mmx40mm,Xact7-9mmx40mm.Benchtestresultsmaynotnecessarilybeindicativeofclinicalperformance.Testresultsshownareformodelsdeemedmosttypicallyselectedforplacementincommoncarotidarterywithareferencediameterof<8mm.Othermodelswerealsotestedandyieldedsimilarresults.N=3.Dataonfile.PreciseProisatrademarkofCordisCorporation,AcculinkisatrademarkofAbbottCardiovascularSystems,Inc,andXactistrademarkofMedNova,Ltd.Xact?StentProtege?StentRXAcculink?StentPrecise?
ProNitinolStentCarotidWALLSTENTRadiopacity:BenchtestthatillustratesthevisibilityofastentunderC-armunderneathsimulatedtissueImagecourtesyofDr.Hoffman
IllustratestheinvivovisibilityofCarotidWALLSTENTandtheRxAcculinkCarotidstent.Maynotbeindicativeofclinicalperformance..
AcculinkisatrademarkofAbbottCardiovascularSystems,Inc,CarotidWALLSTENT?EndoprosthesisRXAcculink?CarotidStent出色的顯影性出色的顯影性DistalInnerROMarkerOuterDistalROMarkerAllPhotographstakenbyBostonScientificCorporation內桿及外鞘上的可回收標記點均不透射線,幫助支架的定位閉環設計跟蹤性極佳的SDS-支架輸送系統卓越的顯影性獨特的可回收能力*
唯一經FDA批準可用于雙側治療頸動脈支架**臨床數據支持*Pleasenotethatreconstrainmentandrepositioningaresubjecttospecificlimitations.PleaserefertoDFUcautionsandwarningsforadditionalinformation.**TheCarotidWALLSTENTEndoprosthesisisindicatedforuseineligiblepatientswithipsilateralorbilateralcarotidarterydiseaseCarotidWALLSTENTTM
頸動脈支架獨特的可回收能力**Pleasenotethatreconstrainmentandrepositioningaresubjecttospecificlimitations.PleaserefertoDFUcautionsandwarningsforadditionalinformation.CarotidWALLSTENT?的獨特設計使其可以重新回收再釋放,幫助支架的精確釋放獨特的導管結構和支架設計使支架在其在釋放少于50%時都可以回收再釋放DFU中與回收相關的注意事項*:只有在必要時才進行回收當支架已解除斑塊時,應該嚴格避免回收回收次數不能超過2次不可回收標記點CarotidWALLSTENT?EndoprosthesisDeliverySystemFinalAssembly.ImagepropertyofBostonScientificCorporation.Notnecessarilytoscale.*Pleasenotethatreconstrainmentandrepositioningaresubjecttospecificlimitations.PleaserefertoDFUcautionsandwarningsforadditionalinformation.獨特的可回收能力*顯示支架回縮的“不可回收點”只要外鞘的回撤未超過不可回收標記點,醫生都可以對支架進行回收重新釋放(不超過2次,未接觸斑塊)閉環設計跟蹤性極佳的SDS-支架輸送系統卓越的顯影性獨特的可回收能力*
唯一經FDA批準可用于雙側治療頸動脈支架**臨床數據支持*Pleasenotethatreconstrainmentandrepositioningaresubjecttospecificlimitations.PleaserefertoDFUcautionsandwarningsforadditionalinformation.**TheCarotidWALLSTENTEndoprosthesisisindicatedforuseineligiblepatientswithipsilateralorbilateralcarotidarterydiseaseCarotidWALLSTENTTM
頸動脈支架閉環設計跟蹤性極佳的SDS-支架輸送系統卓越的顯影性獨特的可回收能力*
唯一經FDA批準可用于雙側治療頸動脈支架**臨床數據支持*Pleasenotethatreconstrainmentandrepositioningaresubjecttospecificlimitations.PleaserefertoDFUcautionsandwarningsforadditionalinformation.**TheCarotidWALLSTENTEndoprosthesisisindicatedforuseineligiblepatientswithipsilateralorbilateralcarotidarterydiseaseCarotidWALLSTENTTM
頸動脈支架28尺寸的正確選擇CarotidWALLSTENTTM
頸動脈支架CarotidWALLSTENT?Monorail?支架輸
溫馨提示
- 1. 本站所有資源如無特殊說明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請下載最新的WinRAR軟件解壓。
- 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請聯系上傳者。文件的所有權益歸上傳用戶所有。
- 3. 本站RAR壓縮包中若帶圖紙,網頁內容里面會有圖紙預覽,若沒有圖紙預覽就沒有圖紙。
- 4. 未經權益所有人同意不得將文件中的內容挪作商業或盈利用途。
- 5. 人人文庫網僅提供信息存儲空間,僅對用戶上傳內容的表現方式做保護處理,對用戶上傳分享的文檔內容本身不做任何修改或編輯,并不能對任何下載內容負責。
- 6. 下載文件中如有侵權或不適當內容,請與我們聯系,我們立即糾正。
- 7. 本站不保證下載資源的準確性、安全性和完整性, 同時也不承擔用戶因使用這些下載資源對自己和他人造成任何形式的傷害或損失。
最新文檔
- 街道土地供應協議書
- 2025年臨床執業醫師考試透徹分析試題及答案
- 中小學教師資格考試的民俗教育與試題及答案
- 貨幣補償協議書丟失
- 就業協議書模板廣東
- 進口代理協議書樣板
- 業務合作干股協議書
- 游艇出游安全協議書
- 腦癱患者幫扶協議書
- 寄宿老師安全協議書
- 庫房管理工作職責與規范化
- 2024-2025學年七年級下學期數學期中測試(浙江瑞安市專用)(含答案)
- 酒駕案件辦理培訓課件
- 2022年10月自考06779應用寫作學試題及答案
- 土壤污染及防治課件
- 視頻編碼技術課件
- 道法《我們的公共生活》第一課時課件
- 科學教學儀器設備借用登記表(精品文檔)
- 火災報警系統安裝檢查記錄
- 壓力性損傷管理制度
- 減重代謝手術護理---副本課件
評論
0/150
提交評論