1、換P570電源步驟 (2011-10-12 11:47) 1.確定在P1-C6/C7位置沒有以下設備,否則只能關機換電源,在線換電源不得超過5分鐘FC 1800 - HSL-2 Ports - 2 CopperFC 1801 - HSL-2 Ports - 2 OpticalFC 1810 - GX Dual-port 4x HCA注:Remote I/O expansion card (FC 1800)Dual-port 4X Host Channel Adapter Infiniband card (FC 1810) 2. 如果P570是由HMC管理的,通過HMC(version6以下版本
2、)刪除設備,方法如下:a 在導航區,展開系統環境b 展開需要更換部件的管理系統c 展開Service Applicationsd 選擇Service Focal Pointe 在內容部分,選擇(Repair Serviceable Event)Install/Add/Remove Hardwaref 在Install/Add/Remove Hardware窗口,點擊System Processor.g 從選擇的菜單上,選擇Remove FRU.h 在Installed enclosure types部分,選擇system or expansion unit來刪除部件i 在可用的FRU類型來選擇
3、插槽來刪除部件j 點擊Next,電源燈開始閃爍k 根據指令更換部件 3. 如何在AIX系統或者邏輯分區上定位壞的部件a 以root用戶登錄AIX系統b 輸入diagc 從Function Selection菜單,選擇Task Selection回車d 選擇Display Previous Diagnostic Results回車e 從Display Previous Diagnostic Results返回界面上選擇Display Diagnostic Log Summary,出現Display Diagnostic Log,返回內容包含按時間排序的一些事件列表f 注意T列表的最近的事件,選擇
4、后按回車g 選擇Commit,將會詳細顯示此事件的信息h 記下事件的位置信息以及相應的SRN號i 退出到命令行下 4. 如果570不是通過HMC管理,更換設備方法如下:a 以root用戶登錄AIX系統b 輸入diagc 從Function Selection菜單,選擇Task Selection回車d 從Task Selection菜單上選擇Identify and Attention Indicators回車e 從列表上選擇故障部件后回車f 選擇Commit,系統故障燈會點亮同時故障部件燈也被點亮(左邊P1-E1,右邊P1-E2)g 開始更換電源h 更換完成后,根據系統提示,退出到命令行下T
5、he FRU listed below is the most probable cause of the failure. If you have a replacement FRU on site you will be guied through an exchange procedure.FRU InformationYou must determine if the repair can continue concurrently.Open the back door of the unit containing the FRU that is being repaired. To
6、continue the repair concurrently,the following conditions must be true Another power supply must already be installed at location E1.This power supply has three LEDS. The LEDs must be set as follows:AC Input-on, not blinkingDC Output-on, not blinkingFault/Identify-offIf any of these conditions are n
7、ot true, the repair can continue only after powering off the unit containing the FRU that is being repaired. If the unit is already powered off, you may proceed with a non-concurrent repair.Select " Next " to continue.Remove the power supplyNote:Two power supplies must be present in the sy
8、stem in order to power on the system unit.If one power supply fails,or you have a system failure that does not stop the fans,the system will continue to operate.You can remove and replace the power supply with the system power on if it is done in LESS THAN FIVE MINUTES After five minutes,the system
9、will power down to prevent the system from over heating.1.Open the back rack door or cover.2.Disconnect the power cable from the backup of the power supply you are servicing.3.Pull the locking handle to pull the power supply out of the power supply byCAUTION: This part or unit is heavy,but has a wei
10、ght smaller than 18 kilograms (39.7 pounds).Use care when lifting.removing,or installing this part or unit(c008).When you have completed these steps,click Next to continue.You must determine if the new power supply is operational. The new power supply is operational if its LEDs are set as follows: AC Input -on, not blinkingDC Output-on, not blinkingFault/Identify-blinking or offIf the LEDs are set differently, you must determine why. Make sure the po
溫馨提示
- 1. 本站所有資源如無特殊說明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請下載最新的WinRAR軟件解壓。
- 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請聯系上傳者。文件的所有權益歸上傳用戶所有。
- 3. 本站RAR壓縮包中若帶圖紙,網頁內容里面會有圖紙預覽,若沒有圖紙預覽就沒有圖紙。
- 4. 未經權益所有人同意不得將文件中的內容挪作商業或盈利用途。
- 5. 人人文庫網僅提供信息存儲空間,僅對用戶上傳內容的表現方式做保護處理,對用戶上傳分享的文檔內容本身不做任何修改或編輯,并不能對任何下載內容負責。
- 6. 下載文件中如有侵權或不適當內容,請與我們聯系,我們立即糾正。
- 7. 本站不保證下載資源的準確性、安全性和完整性, 同時也不承擔用戶因使用這些下載資源對自己和他人造成任何形式的傷害或損失。
最新文檔
- 網絡教育平臺建設與管理方案
- 個體戶用工要不要簽勞動合同
- 居間合同與居間合同協議
- 高速鐵路票務管理
- 房屋短期出租合同
- 應急特種作業培訓機構建設方案
- 淮陰區電梯安全管理人員筆試練習題以及答案
- 建筑工程水電消防合同
- 數學北京課改版15.6 中心對稱圖形教案配套
- 家校合作與溝通協調計劃
- 伊利KA渠道管理培訓材料課件
- 項目質量管理機構結構框圖
- 一例視神經脊髓炎的護理查房
- 學?!拔屙椆芾怼眴栴}臺賬
- 眼解剖(簡單版)課件
- 廚房隔油池清理記錄
- 常見生物相容性實驗匯總
- 綜合探究三 探尋絲綢之路(課堂運用)
- 企業重組相關稅收政策培訓教學課件(38張)
- 肝癌的防治(大眾科普版本)-PPT課件
- 職業危害防治實施管理臺賬
評論
0/150
提交評論