版權說明:本文檔由用戶提供并上傳,收益歸屬內容提供方,若內容存在侵權,請進行舉報或認領
文檔簡介
1、 Pressure transmitters model PTMEx are suitable for liquid and ga-seous media, that do not corrode 1.4404 (316 stainless steel.When connecting, the instruments feature an own intrinsically safe certificated circuitry, type of protection II2 G EEx ib IIC T6 according to ATEX.T wo basic models are ava
2、ilable:Overpressure Model PTMEx 0-1 bar to 0-160 bar Model PTMExFB 0-100 mbar to 0-400 bar both versions also for vacuum- and compound-gauges (with ventilation to atmosphereAbsolute pressure (a 0-1 bar to 0-25 bar (reference point zero absoluteThe pressure transmitters are temperature-compensated an
3、d supply a calibrated output signal. The robust construction makes an appli-cation under difficult conditions possible, e.g. in shipping. The pressure transmitters fulfil the stability requirements for the industrial sector and residential areas according to the European Norm and therefore grant an
4、electromagnetic compatibility.The silicone oil filled piezoresistive sensor is installed in the pressure transmitter element and welded in the pressure connection piece. The elementary sensor is separated from the medium by a thin stainless steel diaphragm. Construction TypeInstallation length: stan
5、dardProcess ConnectionPTMEx : G ½ B (½ "BSP, 1.4404 (316 stainless steelPTMExFB: pressure connection with membrane flush welded G ½ B ( ½ " BSP according to DIN 3852, butG 1 B with O-Ring NBR for pressure range < 1 barMeasuring Cell / SensorPiezoresistive measuring c
6、ell: 1.4404 (316 stainless steelDiaphragm (placed inside: 1.4404 (316 stainless steelSensor Sealing (Measuring cell weldedCase1.4404 / 1.4301 (316 / 304 stainless steel, case protection type IP 65Internal space ventilation for pressure ranges < 16 bar by plug screw fittingPressure Ranges / Overlo
7、adPressure range-dependent, typically at least 2-fold, details see pressure range-table on reverse side Output Signal4.20 mA, 2-wire technique (others see "options"Measuring Accuracy1< ± 0.2% of full scale value,pressure ranges > 60 bar ± 0.3% of full scale valueTemperature
8、 RangesStorage temperature: -40 . + 90 °C (-40 . +194 °FRated temperature: -10 . + 70 °C ( 14 . +158 °FMedium temperature: -10 . + 80 °C ( 14 . +176 °F with temperature decoupler: -10 . +140 °C ( 14 . +284 °FPressure TransmittersWith piezoresistive measuring c
9、ellEx-protection II2 G EEx ib IIC T6 according to ATEX03/11ApplicationsTemperature Influence in the Rated Temperature Range Zero point: < 0.2 % / 10 KMeasuring span: < 0.2 % / 10 KReference Temperature20 °C (68 °FElectrical ConnectionAngular plug connector according to DIN EN 175301-
10、803, 3-pin + protective contact; for assuring the electromagnetic compatibility (EMC please use a shielded cable (e.g. LP/LiMYCY, the shield has to be connected to the case. Electronics Silicone-castSensor FillingSilicone-free, synthetic oilPower Supply6 . 30 VDC, max. acceptable operating voltage 3
11、0 VDC(others see "special versions"Influence of the Power Supply< 0.2% of full scale value / 10 VLoad Impedance2-wire switching (others see "options":R Bmax = (UB 6V / 0.02 ALoad Impedance InfluenceFor load impedance changing 500 Ohm < 0.1 % of full scale valuePosition of I
12、nstallationAnx (standard verticalEx-ApprovalCENELEC-Approval ATEXExplosion control intrinsically safe TÜV 04 ATEX 2432 X II2 G EEx ib IIC T6U max < 30 VDCI max < 150 mA P max < 1WCi < 49 nF Li < 33 µH98121± 0.3% for pressure ranges > 60 barPressure Ranges / Overloads
13、, Special Versions, Accessories and Ordering Information 9Technical changes, replacement of materials and errors excepted. Version with temperature decoupler for temperatures of -10 °C up to +140 °C, order code letters TE Cable connection IP 67, cable ventilation;circular plug connector wi
14、th screw plug M 12, IP 65 Field housing, order code: .FG (e.g. PTMExFG, PTMExFBFG,massive version, srewable cover ring with O-ring sealing for externally accesible adjustable potentiometer, screwable cap for connection chamber with O-ring thread protector, connecting terminals 4 mm2, screwed cable g
15、land M 16 x 1.5 for cable Ø 4.5-10 mm. Other process connections: Model PTMEx: ½" NPT according to DIN EN 837-1 upon request Connection to Zone 0using our screw adapter "Adapt-FS" (see top right, connection to Zone 0 by using an accordingly approved diaphragm seal upon reque
16、stDeflagration volume protection "Adapt-FS ("flame penetration pro-tection" Variant 1 according to data sheet I-11001, made of 1.4571 (316 stainless steel / cannula 1.4301 (304 stainless steel, process connection G ½ B (½ " BSP according to EN 837-1,with CE-Type Examina
17、tion Certificate PTB 99 ATEX 4023 X accor-ding to standard 94/9/EG, marking of this protection system: II II CBasic model: diaphragm placed inside PTMExdiaphragm flush welded PTMExFBCase configuration: standard case: no additional code letters; field housing: FG Medium-temperature: standard version
18、no additional (up to 80 °C code letters; with temperature decoupler (up to 140 °C, see left side: TE T ype of protection: ibMarking withtemperature class:T4, T5 or T6Pressure type: overpressureabsolute pressure:(aPressure range: see table above, e.g. 0-4 barOutput signal: standard: 4 . 20
19、mA,optional0 . 20 mASpecifics:e.g. process connection ½" NPT,M 22x1.5 and others, see left; special position of installation, other special versionsupon requestExamples:PTMEx ib T6 (r -1/+3 bar, 4.20 mA(that means: PTMEx pressure transmitter with Ex-protection, standard version for max. me
20、dium temperature. +80 °C, type of protection ib, temperature class T6, for relative pressure -1/+3 bar, output signal 4 . 20 mA, pressure connection G ½ BPTMExFG TE ib T6 (a 0-6 bar, 0.20 mA(that means: PTMExFG pressure transmitter with field housing with Ex-protection, with temperature de
21、coupler for max. medium temperature +140 °C, type of pro-tection ib, temperature class T6, for absolute pressure 0-6 bar, output signal 0 . 20 mA (3-wire technique, pressure connection G ½ BPTMExFB ib T5 (r 0-400 mbar, 4.20 mA, G1B(that means: PTMExFB pressure transmitter with Ex-protectio
22、n standard version for max. medium temperature +80 °C, type of protection ib, marking with tempera-ture class T5, for relative pressure 0-400 mbar, output signal 4 . 20 mA , (2-wire technique, pressure connection G 1 BCase Configurations, Dimensional Data and Weights, Connecting Diagram 9Technical changes, replacement of materials and errors excepted.Standard Case(no additional code letterscrewed cable gland M 16x1for standard case: approx. 0.200 kgwith temper
溫馨提示
- 1. 本站所有資源如無特殊說明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請下載最新的WinRAR軟件解壓。
- 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請聯系上傳者。文件的所有權益歸上傳用戶所有。
- 3. 本站RAR壓縮包中若帶圖紙,網頁內容里面會有圖紙預覽,若沒有圖紙預覽就沒有圖紙。
- 4. 未經權益所有人同意不得將文件中的內容挪作商業(yè)或盈利用途。
- 5. 人人文庫網僅提供信息存儲空間,僅對用戶上傳內容的表現方式做保護處理,對用戶上傳分享的文檔內容本身不做任何修改或編輯,并不能對任何下載內容負責。
- 6. 下載文件中如有侵權或不適當內容,請與我們聯系,我們立即糾正。
- 7. 本站不保證下載資源的準確性、安全性和完整性, 同時也不承擔用戶因使用這些下載資源對自己和他人造成任何形式的傷害或損失。
最新文檔
- 2025年直播行業(yè)規(guī)范化與商業(yè)模式創(chuàng)新:產業(yè)鏈整合與生態(tài)優(yōu)化報告
- 環(huán)保設備制造業(yè)市場競爭與創(chuàng)新產品市場前景研究報告
- 2025年班主任個人工作小結與班主任個人工作心得總結
- 金融科技在普惠金融中的金融科技創(chuàng)新趨勢與挑戰(zhàn)研究報告
- 高一化學教師教學工作總結
- 司爐工工作總結模版
- 文化產業(yè)園產業(yè)集聚與服務體系構建中的文化產業(yè)產業(yè)鏈協同效應報告
- 英語社團年度工作總結模版
- 教育行業(yè)招生營銷數字化策略與教育改革策略報告2025
- 汽車共享出行平臺運營模式創(chuàng)新與用戶出行需求洞察報告
- 海洋油氣開發(fā)生產簡介課件
- 卒中相關肺炎的指南解讀
- 六下統編版復習2形近字
- 硒知識科普手冊
- 起重吊裝作業(yè)審批表
- 最新三角形的特性優(yōu)質課教學設計公開課教案
- 新版冀教版科學四年級下冊全冊教案(雙面打印)
- MSAGRR數據自動生成工具(已經解密)
- 招商工作策略與路徑pptPPT通用課件
- DBJ 33-T 1268-2022工程建設工法編制標準(高清正版)
- 漫畫教你精益生產
評論
0/150
提交評論