




版權(quán)說(shuō)明:本文檔由用戶提供并上傳,收益歸屬內(nèi)容提供方,若內(nèi)容存在侵權(quán),請(qǐng)進(jìn)行舉報(bào)或認(rèn)領(lǐng)
文檔簡(jiǎn)介
目錄一、工程概況···················································1二、施工管理目標(biāo)···············································1三、施工部署···················································1四、施工進(jìn)度計(jì)劃···············································5五、施工技術(shù)措施···············································6六、建立健全技術(shù)管理制度······································27七、施工質(zhì)量保證措施·········································28八、工程養(yǎng)護(hù)和冬、雨季施工措施································29九、嚴(yán)格執(zhí)行國(guó)家的有關(guān)施工規(guī)范、標(biāo)準(zhǔn)··························30十、文明施工和安全生產(chǎn)措施·······························30十一、施工合理化建議和降低成本措施····························33十二、工程質(zhì)量通病防治措施····································34十三、工程竣工檔案資料的整理及管理措施························35建筑裝修施工方案工程概況:主廠房占地面積8195m2,煤倉(cāng)間占地面積1251m2;外墻0.5米以上均采用單層壓型鋼板外墻板,0.6米以下均為200厚頁(yè)巖磚砌體,內(nèi)墻為200厚A3.5加氣砼砌體,零米以下、女兒墻及浴室?guī)?.5米高以下墻體采用200厚頁(yè)巖磚砌體;-0.06米位置設(shè)防潮層。普通地面及樓面采用彩色耐磨地坪做法,配電間、集控樓、電子設(shè)備間等電氣用房及工程師站、交接班室及會(huì)議室采用防靜電膠地板,煤倉(cāng)間皮帶機(jī)層采用耐磨防水地坪。衛(wèi)生間地面及墻面均貼面磚,蓄電池室采用防腐地坪,加藥間、藥品貯存采用耐酸地磚鋪貼。蓄電池室及加藥間、藥品貯存內(nèi)墻采用防腐涂料,其他內(nèi)墻采用乳膠漆墻面,外墻設(shè)墻裙及散水。挑檐、窗眉、陽(yáng)臺(tái)底均設(shè)滴水線,門(mén)窗采用本色鋁合金白色普通玻璃系列,外墻門(mén)采用鋼板門(mén),設(shè)備進(jìn)出及檢修門(mén)采用鋼制電動(dòng)卷簾門(mén)。運(yùn)行層及1#、2#、3#樓梯采用亞光不銹鋼欄桿,其他各層采用油漆鋼管欄桿,鋼屋架及支撐、吊車(chē)梁、電梯井構(gòu)架等鐵件用防銹漆打底,調(diào)和漆兩道,汽機(jī)房6.9米層及13.7米層主郵箱及油管閥門(mén)外緣水平5米范圍內(nèi)的鋼梁、鋼柱采用防火隔熱措施進(jìn)行全保護(hù),有耐火要求,所對(duì)應(yīng)的屋面也需耐火。屋面工程采用雙層卷材防水,防水層采用SBS卷材防水,上面聚苯乙烯保溫隔熱板上做40厚有筋細(xì)石砼面層。1.2裝修材料色彩及材質(zhì)需取得業(yè)主和設(shè)計(jì)方認(rèn)可,材料要求必須是一級(jí)品。施工管理目標(biāo)2.1質(zhì)量控制管理目標(biāo)本工程質(zhì)量要求為優(yōu)良等級(jí),并符合****投資集團(tuán)公司MERGEFIELD發(fā)文文號(hào)****內(nèi)規(guī)[2003]340號(hào)文《火電工程達(dá)標(biāo)投產(chǎn)考核辦法》的達(dá)標(biāo)投產(chǎn)及原電力工業(yè)部、****公司頒布的質(zhì)量驗(yàn)評(píng)標(biāo)準(zhǔn)優(yōu)良等級(jí)條件,確保省部級(jí)優(yōu)質(zhì)工程,爭(zhēng)創(chuàng)“魯班獎(jiǎng)”。2.2安全文明施工管理目標(biāo)(1)杜絕人身死亡事故;(2)杜絕重大機(jī)械設(shè)備事故;(3)杜絕重大火災(zāi)事故;(4)杜絕主要設(shè)備的損壞事故;(5)杜絕負(fù)主要責(zé)任的重大交通事故;(6)杜絕重大環(huán)境污染事故;(7)杜絕重大垮(坍)塌事故;(8)避免和嚴(yán)格控制一般安全事故。2.3文明施工現(xiàn)場(chǎng)控制管理目標(biāo)及保證措施(1)文明施工現(xiàn)場(chǎng)控制管理目標(biāo):強(qiáng)化施工現(xiàn)場(chǎng)科學(xué)管理,建成市級(jí)文明樣板工地。(2)保證措施:我方將主要對(duì)現(xiàn)場(chǎng)的垃圾清運(yùn)、材料堆放、噪聲控制、大氣污染預(yù)防、水污染預(yù)防、安全設(shè)施懸掛、飲食生活衛(wèi)生等方面進(jìn)行規(guī)范管理。施工組織部署3.1有完善的施工、技術(shù)管理措施為加強(qiáng)和規(guī)范本工程招標(biāo)項(xiàng)目的施工管理,完善施工、技術(shù)管理措施,結(jié)合本工程和本項(xiàng)目部的實(shí)際情況,遵循如下制度的,主要適用本項(xiàng)目工程施工技術(shù)管理的制度,涉及質(zhì)量管理、技術(shù)管理、物資管理等方面。(1)質(zhì)量責(zé)任制(2)質(zhì)量驗(yàn)收制度(3)質(zhì)量事故報(bào)告制度和處理制度(4)質(zhì)量考核及獎(jiǎng)懲辦法(5)技術(shù)責(zé)任制(6)施工組織設(shè)計(jì)及技術(shù)文件編審制度(7)設(shè)計(jì)變更管理制度(8)材料代用管理制度(9)技術(shù)檢驗(yàn)制度(10)技術(shù)培訓(xùn)及考核制度(11)技術(shù)檔案管理制度(12)圖紙會(huì)審制度(13)技術(shù)交底制度(14)樣板施工控制制度(15)原材料、半成品、成品和設(shè)備的采購(gòu)、保管、發(fā)放管理制度(16)鋼材、水泥跟蹤管理制度3.2管理人員配置根據(jù)工程的實(shí)際情況,配備生產(chǎn)經(jīng)理1人,建筑裝修施工員2人,安全員1人,質(zhì)檢員1人,為了解決施工過(guò)程中的問(wèn)題,還配備1名技術(shù)人員,并且人員具有一定的建筑裝修經(jīng)驗(yàn),業(yè)務(wù)能力較強(qiáng)的管理骨干。3.3工種配置和人員使用為了確保工程質(zhì)量,采用施工經(jīng)驗(yàn)豐富的作業(yè)人員。要求業(yè)務(wù)精通、技術(shù)能力強(qiáng)、人員素質(zhì)好,善打硬仗。人員(其中電工、電焊工、架子工、機(jī)操工為經(jīng)過(guò)相關(guān)部門(mén)專門(mén)培訓(xùn)并獲證的人員)進(jìn)場(chǎng)后進(jìn)行安全學(xué)習(xí)并組織技術(shù)安全交底。施工人員進(jìn)場(chǎng)后首先進(jìn)行技術(shù)交底并有書(shū)面簽名,而后進(jìn)行安全操作考試。施工人員統(tǒng)一著裝,統(tǒng)一安排食宿,服從項(xiàng)目部管理。3.4施工部署砌筑及裝修應(yīng)密切與結(jié)構(gòu)及安裝配套進(jìn)行,盡量往前壓時(shí)間,否則,一旦設(shè)備安裝運(yùn)行后需填作業(yè)票及顧忌較多,施工較困難。3.4.1施工平面布置.1施工臨時(shí)道路和垂直運(yùn)輸:水平運(yùn)輸項(xiàng)目部有裝載機(jī),大平板,翻斗車(chē)等,可以滿足水平運(yùn)輸施工要求。垂直運(yùn)輸利用各建筑的樓梯通道及租用提升機(jī),在煤倉(cāng)間YH~YG軸靠1#送風(fēng)機(jī)位置設(shè)1#提升機(jī),靠2#送風(fēng)機(jī)位置留給鋼煤斗安裝運(yùn)輸。擴(kuò)建端C~B間設(shè)2#提升機(jī),3#提升機(jī)設(shè)置在固定端附近。.2施工臨建設(shè)施在小臨建場(chǎng)地設(shè)置集中攪拌站,砂漿采用拌合站集中拌制,采用罐裝水泥;設(shè)置建筑材料堆放區(qū)域及散裝水泥倉(cāng)庫(kù)。(1)工地辦公室在臨建設(shè)置協(xié)作隊(duì)伍辦公室,方便管理及隊(duì)伍熟悉圖紙、技術(shù)研究。(2)材料倉(cāng)庫(kù)在臨建設(shè)置臨時(shí)倉(cāng)庫(kù),分別堆放、保存油漆(涂料)、五金和其他材料,所有的臨時(shí)倉(cāng)庫(kù)都必須設(shè)置足夠數(shù)量的滅火器和防火砂。施工器具均按指定位置擺放,五金等配件設(shè)立專用貨架,并標(biāo)識(shí)清楚。(3)加工場(chǎng)所在臨建設(shè)置協(xié)作隊(duì)伍木制品加工場(chǎng)和綜合加工場(chǎng),木制品加工場(chǎng)按原材料堆放處、臺(tái)式圓盤(pán)鋸、半成品堆放處、加工平臺(tái)、成品堆放處布置;綜合加工場(chǎng)內(nèi)布置電焊機(jī)、臺(tái)鉆桌和鉆床等,但注意必須設(shè)置足夠的滅火器和防火砂。機(jī)械設(shè)備均應(yīng)可靠接地。并應(yīng)有漏電保護(hù)裝置,并應(yīng)設(shè)置醒目警示牌。(4)砂、石和水泥堆放及拌合站砂、石等材料設(shè)置堆料場(chǎng),砂漿及零星砼集中拌制。拌合站采用罐裝水泥。水泥堆放應(yīng)方便保管和使用。進(jìn)場(chǎng)的散裝水泥存放在水泥庫(kù)內(nèi);施工面只放置當(dāng)天所需的散裝水泥,但必須注意水泥的防水、防潮和不能超高堆放。.3施工用水水源引致電廠給水管網(wǎng)。現(xiàn)場(chǎng)管道、走向、容量的布置要滿足施工要求,在拌合站設(shè)置水箱或水桶貯存一定量的備用水。施工面樓層給水管從結(jié)構(gòu)樓梯中縫引致,出水口用閘閥控制,水口下方設(shè)專用接水容器,容器里的水要及時(shí)用掉不得滿溢。給水管采用熱熔管。.4施工用電現(xiàn)場(chǎng)管線、走向、容量的布置服從總體安排和管理。電源從專業(yè)閘箱接出。施工面樓層電源線從結(jié)構(gòu)樓梯中縫引致,各層設(shè)置Ⅱ級(jí)電源箱一套,施工用電均從設(shè)立的Ⅱ級(jí)電源箱中接出,電源箱設(shè)置漏電保護(hù)器和自動(dòng)空氣開(kāi)關(guān),電線采用三相五線制,單相三線制懸掛式接至各施工用電區(qū)。施工用電地面電線均采用橡皮電纜,交織線及白線不得使用,所有施工面能接通并滿足施工要求。安監(jiān)人員和專業(yè)電工應(yīng)勤檢查工地用電狀態(tài),發(fā)現(xiàn)問(wèn)題應(yīng)及時(shí)處理,對(duì)不能處理的問(wèn)題應(yīng)及時(shí)向上級(jí)匯報(bào)。.5棄料處理服從業(yè)主的安排和管理,建筑垃圾應(yīng)及時(shí)清掃裝袋,集中堆放在業(yè)主指定的地方,定時(shí)清運(yùn)出現(xiàn)場(chǎng)。.6現(xiàn)場(chǎng)安全、文明施工管理服從我部現(xiàn)場(chǎng)統(tǒng)一的安全、文明施工管理,并認(rèn)真按照我部安全文明施工樣板工程的規(guī)定操作。3.5施工準(zhǔn)備與施工資源計(jì)劃配置施工準(zhǔn)備(1)技術(shù)準(zhǔn)備首先對(duì)施工圖紙吃透,然后會(huì)審施工圖紙。對(duì)設(shè)計(jì)提出合理化建議,并編制施工技術(shù)措施,作業(yè)指導(dǎo)和技術(shù)交底文件,對(duì)各種材料、設(shè)備、制品等的規(guī)格、性能加工圖紙說(shuō)明,進(jìn)行資料收集和整理。(2)現(xiàn)場(chǎng)準(zhǔn)備施工現(xiàn)場(chǎng)準(zhǔn)備包括檢查現(xiàn)場(chǎng)土建結(jié)構(gòu)完成情況,對(duì)基底進(jìn)行驗(yàn)收,測(cè)量放線,拆除障礙物,清理場(chǎng)地,疏通道路和運(yùn)輸,安置臨時(shí)施工用水、用電,生產(chǎn)和生活臨時(shí)設(shè)施。施工資源計(jì)劃配置(1)材料、機(jī)具和加工半成品計(jì)劃配置施工機(jī)具也隨人員逐步進(jìn)場(chǎng),材料在第一批技術(shù)人員進(jìn)場(chǎng)后首先拿出計(jì)劃,在甲方認(rèn)可的廠家進(jìn)貨,以最快的方式運(yùn)抵工地。(2)配備足夠的施工機(jī)械設(shè)備,采用先進(jìn)的施工技術(shù)和施工方法。4施工進(jìn)度計(jì)劃4.1本工程的工期目標(biāo)按照業(yè)主二級(jí)進(jìn)度計(jì)劃,分項(xiàng)工程的工期目標(biāo)為序號(hào)分項(xiàng)工程完成時(shí)間1主廠房樓地面工程程2009-10--292主廠房門(mén)窗工程2009-10--313主廠房裝飾工程2009-12--284主廠房屋面工程2009-05--305主廠房給排水工程程2009-07--306主廠房通風(fēng)、空調(diào)調(diào)工程2009-09--157主廠房照明工程2009-10--118主廠房圍護(hù)結(jié)構(gòu)工工程2009-05--189集控樓建筑裝飾工工程2009-05--1510集控樓建筑設(shè)備安安裝工程2009-05--3011化水建筑裝飾工程程2009-04--3012化水建筑設(shè)備安裝裝工程2009-04--304.2保證措施施工項(xiàng)目進(jìn)度控制是在既定的工期內(nèi),編制出最優(yōu)的施工進(jìn)度計(jì)劃,在執(zhí)行過(guò)程中,經(jīng)常檢查施工實(shí)際進(jìn)度情況并將其與計(jì)劃進(jìn)度相比較,找出偏差,進(jìn)行調(diào)整,不斷如此循環(huán),直至工程竣工驗(yàn)收。施工進(jìn)度計(jì)劃管理體制:總控制計(jì)劃→月計(jì)劃→周計(jì)劃→日計(jì)劃。施工進(jìn)度控制措施:有組織保證措施、技術(shù)保證措施、質(zhì)量保證措施、安全保證措施、合同措施、經(jīng)濟(jì)措施和信息措施等。每星期召開(kāi)1次生產(chǎn)例會(huì),每天召開(kāi)碰頭會(huì),找出拖延進(jìn)度計(jì)劃的原因,并采取相應(yīng)措施。實(shí)行合理的工期目標(biāo),采用分段控制點(diǎn)獎(jiǎng)懲制度。材料組織(1)按圖紙要求及簽證的材料樣板,進(jìn)行大批量的材料采購(gòu),所有的主要材料必須是一級(jí)品并保證三證齊全,關(guān)鍵在進(jìn)貨過(guò)程中精挑細(xì)選,確保材料質(zhì)量達(dá)到本工程的要求。(2)從材料的選購(gòu)、加工、包裝、運(yùn)輸?shù)葘哟危瑢訉影押觅|(zhì)量關(guān),最后到工地經(jīng)質(zhì)檢員和物資部驗(yàn)收入庫(kù)。交叉施工項(xiàng)目部統(tǒng)一安排各分項(xiàng)工程,在互不影響的情況下進(jìn)行交叉作業(yè),若存在交叉作業(yè)及與其他建設(shè)單位交叉作業(yè),則需提前溝通、提前預(yù)控。補(bǔ)救措施:配置技術(shù)能力強(qiáng),善打硬仗,并有豐富的施工經(jīng)驗(yàn)的施工隊(duì)伍組成作業(yè)層,承擔(dān)本工程的施工任務(wù)。某些特殊原因造成工期延誤時(shí),項(xiàng)目部將集中力量把損失的時(shí)間搶回來(lái),對(duì)工作面較大的分項(xiàng)工程通過(guò)增加人手和設(shè)備等方式,全方位施工以贏得時(shí)間和進(jìn)度;對(duì)工作面較小而難度又大的分項(xiàng)工程,則選派技術(shù)最好的專業(yè)師傅精工細(xì)作,加班加點(diǎn)。5施工技術(shù)措施5.1施工程序和施工方案合理安排施工程序,組織各工種搭接交叉作業(yè),是保證施工進(jìn)度計(jì)劃落實(shí)的重要步驟。施工程序如下:按先主體后分部,先建筑后裝飾,先上(吊頂)后下(地面處理)的方式進(jìn)行。各工種之間原則上按水、電(隱蔽工程)→泥工→木工→油漆工→水、電安裝的順序安排施工。由于,本招標(biāo)工程的工程量相對(duì)較大,工期相對(duì)較短,施工工藝相對(duì)復(fù)雜。因此擬定工作面同時(shí)鋪開(kāi),由上而下,每層作為一施工工作面,同時(shí)進(jìn)行施工的方案,對(duì)不影響下道工序,不影響其他專業(yè)或工種的工程,可提前進(jìn)行,各工種工序采用平行施工法按施工計(jì)劃進(jìn)行施工,減少交叉立體作業(yè),充分利用施工場(chǎng)地,嚴(yán)格遵守整體安排,精心組織施工。5.2主要項(xiàng)目的施工技術(shù)措施砌筑工程.1質(zhì)量標(biāo)準(zhǔn)建筑砌體要求達(dá)到清水墻要求,清水墻對(duì)砌塊材料要求極高。首先磚的大小要均勻,棱角要分明,色澤要統(tǒng)一。普通砌塊難達(dá)到清水墻體標(biāo)準(zhǔn)要求,砌塊要求邊角整齊,色澤均勻,這種磚價(jià)錢(qián)一般是普通磚的5~10倍。其次,砌筑工藝十分講究,灰縫要一致,陰陽(yáng)角要鋸磚磨邊,接槎要嚴(yán)密和美感,門(mén)窗洞口要用拱、花等等工藝。清水墻體除了允許偏差值比普通墻體嚴(yán)格外,還講究觀感。使用的砌塊和原材料,其技術(shù)性能、強(qiáng)度、品種必須符合設(shè)計(jì)要求,并有出廠合格證,規(guī)定試驗(yàn)項(xiàng)目必須符合標(biāo)準(zhǔn)。 砂漿的品種、強(qiáng)度必須達(dá)到設(shè)計(jì)要求,按規(guī)定制作試塊,試壓強(qiáng)度不得低于設(shè)計(jì)強(qiáng)度。 砌塊錯(cuò)縫應(yīng)符合規(guī)定,不得出現(xiàn)豎向通縫,壓縫尺寸應(yīng)達(dá)到標(biāo)準(zhǔn)要求。 墻轉(zhuǎn)角處,交接處宜同時(shí)砌筑,必須留槎時(shí)應(yīng)留斜槎,斜槎的長(zhǎng)度應(yīng)等于或大于斜槎高度,灰縫厚度均勻一致。 墻體灰縫飽滿,砌塊平順,不得出現(xiàn)破槎、松動(dòng)。 拉結(jié)鋼筋、鋼筋網(wǎng)片規(guī)格、根數(shù)、設(shè)置間距、設(shè)置位置、長(zhǎng)度應(yīng)符合前面所述內(nèi)容要求。.2材料要求(1)水泥砌筑砂漿采用普通硅酸鹽水泥,標(biāo)號(hào)32.5。水泥按品種、標(biāo)號(hào)、出場(chǎng)日期分別堆放,并保持干燥。如與水泥標(biāo)號(hào)不明或出場(chǎng)日期超過(guò)三個(gè)月時(shí),應(yīng)復(fù)查試驗(yàn)并按試驗(yàn)結(jié)果使用,不同品種的水泥不得混合使用。(2)砂砂采用中砂。不得含有草根泥塊等雜物,砂的含泥量不超過(guò)5%。(3)水采用電廠提供水源(4)石灰粉砂漿外摻料采用的石灰粉經(jīng)現(xiàn)場(chǎng)充分熟化(一般以7d以上為宜)后使用。(5)砌塊0.6米以下均為240厚頁(yè)巖磚砌體,零米以下、女兒墻及浴室?guī)?.5米高以下墻體采用240厚頁(yè)巖磚砌體;內(nèi)墻為200厚A3.5加氣砼砌體。磚進(jìn)入現(xiàn)場(chǎng)按施工平面布置圖進(jìn)行碼垛堆放,裝卸時(shí)注意保護(hù)磚的棱角不受損傷。在堆放過(guò)程中每一層磚中間要加棉氈,目的是減少堆放時(shí)磚與磚之間的碰撞,減少磚自身以及磚棱角的損傷。在同樓層上應(yīng)用同一磚廠的磚,且色澤均勻,規(guī)格尺寸一致,以確保墻體的均質(zhì)性。.3工藝流程清理基層→彈線→找平→綁扎構(gòu)造柱鋼筋→立皮數(shù)桿→拉結(jié)筋植筋→排磚→盤(pán)角→掛線→砌筑及放預(yù)埋件→砌砌塊墻體→勾縫→綁扎圈梁、現(xiàn)澆過(guò)梁鋼筋→支模、澆筑圈梁、過(guò)梁砼→砌筑圈梁、過(guò)梁上砌體→勾縫→支構(gòu)造柱模板、澆筑砼→砌梁(板)下口斜撐磚→安裝門(mén)框、敷設(shè)墻內(nèi)電線管及接線盒→墻體修補(bǔ)→墻面裝修5.2.2砌塊排列方法和要求5.2.2.1砌塊排列時(shí),必須根據(jù)設(shè)計(jì)圖紙和砌塊尺寸、垂直灰縫的寬度、水平灰縫的厚度等計(jì)算砌塊的皮數(shù)及排數(shù),以保證砌體的尺寸。5.2.2.2砌筑前,應(yīng)對(duì)砌塊的外觀質(zhì)量進(jìn)行檢查,不得使用斷裂砌塊;缺菱掉角、尺寸規(guī)格不一致的應(yīng)去除;色澤不一致的不得使用。此外,應(yīng)清除砌塊表面的污物和碎屑。5.2.2.3外墻轉(zhuǎn)角處和縱橫交接處的砌塊應(yīng)相互咬搓,交錯(cuò)搭砌,應(yīng)避免與其他墻體材料混用。5.2.2.4砌體的上下皮砌塊應(yīng)互相錯(cuò)縫搭砌,搭接長(zhǎng)度不宜小于砌塊長(zhǎng)度的三分之一。砌體的垂直與窗洞口邊線要避免通縫。5.2.2.5凡砌體中需固定門(mén)窗及其他構(gòu)件、以及擱置過(guò)梁、擱板等部位,應(yīng)盡量采用大規(guī)格和規(guī)則整齊的砌塊砌筑,不得使用零星砌塊砌筑。施工要點(diǎn)與一般構(gòu)造措施.1砌筑前,應(yīng)將樓地面找平,然后按設(shè)計(jì)圖紙放出墻體的軸線,并立好皮數(shù)桿。在墻體底部采用普通粘土磚砌筑(或澆筑C15素砼),寬度同墻厚,將樓層砌體的底部砌筑起點(diǎn)在同一水平高程。.2采用混合砂漿砌筑時(shí),砂漿的強(qiáng)度等級(jí)不宜低于M2.5。磚塊在砌筑24小時(shí)前應(yīng)澆水濕潤(rùn),以確保加氣塊不再吸收砂漿中的水份,從而保證了砂漿的強(qiáng)度。6.3砌筑時(shí),灰縫應(yīng)橫平豎直,豎向灰縫宜采用內(nèi)外臨時(shí)夾板灌縫,且灌縫密實(shí)。垂直灰縫的寬度不得小于20mm,水平灰縫的厚度不得大于15mm,砂漿飽滿度不低于80%,砌筑時(shí)要邊砌邊用原漿進(jìn)行勾縫處理。6.4內(nèi)外墻交接處和外墻轉(zhuǎn)角處應(yīng)咬槎砌筑,并在沿墻高1m。臨時(shí)間斷處應(yīng)砌成階梯形斜槎,斜槎補(bǔ)砌處必須將接槎處表面清理干凈,澆水濕潤(rùn),并填實(shí)砂漿,保持灰縫平直。6.5砌體的上下皮砌塊應(yīng)錯(cuò)縫搭砌,相互錯(cuò)開(kāi)300mm,并》150mm。當(dāng)《150mm或當(dāng)搭砌的長(zhǎng)度小于砌塊長(zhǎng)度的三分之一時(shí),水平灰縫中應(yīng)設(shè)置鋼筋加強(qiáng),砼柱、墻沿高度每隔三皮磚高設(shè)置一道拉結(jié)筋與砌體構(gòu)造鋼筋連接。6.6勾縫必不可少,抹灰要選擇時(shí)機(jī)勾縫是很重要一道工序,可消除砌體灰縫中初始狀態(tài)的微細(xì)裂縫,勾縫并非只適用于清水墻,為防止?jié)B漏,即使墻體日后要抹灰,勾縫也是必要的。清水外墻面和有防水抗?jié)B要求的清水內(nèi)墻面的灰縫縫型宜采用凹圓或V形縫,不宜采用平縫或凸圓形縫。砌塊混水墻應(yīng)隨砌隨用原漿勾縫,應(yīng)在灰縫砂漿達(dá)到“指紋硬化”(手指壓出清晰指紋而砂漿不粘手)時(shí)即刻進(jìn)行勾縫,勾縫時(shí)缺灰處應(yīng)補(bǔ)漿壓實(shí)、壓平,并形成凹縫,凹進(jìn)墻面2mm,以增強(qiáng)其抹灰層的粘結(jié)度。勾縫完后應(yīng)把墻面的余灰清掃干凈,待砂漿硬化后宜對(duì)墻體進(jìn)行噴水養(yǎng)護(hù),養(yǎng)護(hù)時(shí)間不宜少于24h。水平灰縫的勾縫工具,長(zhǎng)度宜為450mm,豎縫的勾縫工具斷面相同,長(zhǎng)度較小。6.6砌塊的切鋸鋸、鉆孔打眼眼、開(kāi)槽等采采用專用設(shè)備備、工具進(jìn)行行加工,不得得隨意砍鑿。6.7加氣砼砌塊塊每天砌筑高高度不宜超過(guò)過(guò)1.8m。6.8為防止加氣氣砼砌體開(kāi)裂裂,墻體長(zhǎng)度度超過(guò)5m,中間宜設(shè)設(shè)置構(gòu)造柱。6.9無(wú)可靠措施施時(shí),不宜在在負(fù)溫下砌筑筑加氣砼砌體體墻體。6.10砌到接近近上層梁,板板時(shí),宜用普普通磚斜砌擠擠緊,磚傾斜斜角度為60°左右,砂漿漿應(yīng)飽滿,補(bǔ)補(bǔ)砌磚應(yīng)在砌砌體施工完7天后進(jìn)行。6.11凡有穿過(guò)過(guò)加氣砼砌塊塊墻體的管道道,應(yīng)采取可可靠措施,保保證施工質(zhì)量量,嚴(yán)格防止止管道滲水、漏水和結(jié)露,以免免造成氣砼的的鹽析、凍融融破壞和墻體體滲漏,影響響使用。6.12為防止窗窗墻體產(chǎn)生八八字裂縫,在在窗盤(pán)位置增增設(shè)砼標(biāo)呈不不小于C20現(xiàn)澆窗臺(tái)壓頂頂,長(zhǎng)度為沿沿墻體通長(zhǎng)設(shè)設(shè)置且與構(gòu)造造柱或框架連連接,厚度在在60-1000mm內(nèi),內(nèi)內(nèi)配不小于22Φ6鋼筋。6.13凡與砌體體墻相連的砼砼柱、墻、梁梁面在砌筑前前進(jìn)行表面處處理,方法是是堿水清洗砼砼表面油污,用107膠素水泥土漿摻少量砂子噴刷一道,砌體與砼之間用砂漿滿灌,做法同豎縫。6.14鋼筋混凝凝土構(gòu)造柱施施工6.14.1馬馬牙槎從每層層柱腳開(kāi)始,先先退后進(jìn)。鋼鋼筋應(yīng)除銹、調(diào)調(diào)直。對(duì)預(yù)留留的伸出鋼筋筋,不應(yīng)在施施工中任意彎彎折。如有歪歪斜,應(yīng)在澆澆灌混凝土前前校正到準(zhǔn)確確位置。箍筋筋應(yīng)按要求位位置與豎筋綁綁扎牢固。6.14.2構(gòu)構(gòu)造柱和圈梁梁的模板可用用木模或鋼模模。所有模板板需涂抹脫模模劑。在每層層磚墻砌好后后,將模板內(nèi)內(nèi)的落地灰、磚磚渣和其它雜雜物清除干凈凈。清除完畢畢應(yīng)立即封模模。模板必須須與所在墻的的兩側(cè)嚴(yán)密貼貼緊,支撐牢靠,防止板縫漿,可以沿馬牙牙槎周邊貼雙雙面膠帶。6.14.3混凝凝土澆筑、振振搗:在澆灌構(gòu)造柱混凝凝土前,必須須將磚砌體和和模板澆水潤(rùn)潤(rùn)濕,構(gòu)造柱柱根部施工縫縫處,在澆筑筑前宜先鋪55cm厚與混混凝土配合比比相同的水泥泥砂漿或減石石子混凝土。構(gòu)構(gòu)造柱的混凝凝土坍落度宜宜為50~70MM,以保證澆澆搗密實(shí)。亦亦可據(jù)施工條件件、季節(jié)不同同,在保證澆搗搗密實(shí)的情況況下加以調(diào)整整。混凝土隨隨拌隨用,拌拌合好的混凝凝土應(yīng)在1.5H內(nèi)澆灌完,超超過(guò)1.5H的混凝土不不得使用,并并不得再次拌拌合后使用。6.14.4澆筑筑方法:用吊吊斗供料時(shí),不不應(yīng)用吊斗直直接將混凝土土卸入模內(nèi),先先將吊斗降至至距鐵盤(pán)50~60cm處,將將混凝土卸在在鐵盤(pán)上,再再用鐵鍬或泥泥桶灌入模內(nèi)內(nèi),可以在構(gòu)構(gòu)造柱頂端設(shè)設(shè)置專業(yè)下料料斗,砼料通通過(guò)下料斗進(jìn)進(jìn)入。構(gòu)造柱的混凝土澆澆灌可以分段段進(jìn)行,每段段高度不宜大大于2.0MM。在施工條條件較好并能能確保澆灌密密實(shí)時(shí),亦可可每層一次澆澆灌。預(yù)制大大梁、圈梁和和柱的接頭處處,則必須在在同一層內(nèi)一一次澆灌。澆澆搗構(gòu)造柱混混凝土?xí)r,宜宜用插入式振振搗棒,分層層搗實(shí)。振搗搗棒隨振隨拔拔,每次振搗搗層的厚度不不應(yīng)超過(guò)振搗搗棒長(zhǎng)度的1.25倍。振搗時(shí)時(shí),振搗棒應(yīng)應(yīng)避免直接碰碰觸磚墻,并并嚴(yán)禁通過(guò)磚磚墻傳振。6.14.5混凝凝土養(yǎng)護(hù):混混凝土澆筑完完12h以內(nèi),應(yīng)對(duì)對(duì)混凝土加以以覆蓋并澆水水養(yǎng)護(hù)。常溫溫時(shí)每日至少少澆水兩次,養(yǎng)養(yǎng)護(hù)時(shí)間不得得少于1d。6.14.6成品品保護(hù)澆筑混凝凝土?xí)r,不得得污染清水磚磚墻面。若有有灰漿,應(yīng)及及時(shí)清除。振搗混凝土?xí)r,不不得碰動(dòng)鋼筋筋、埋件,防防止移位。鋼筋有踩踩彎、移位或或脫扣時(shí),及及時(shí)調(diào)整、補(bǔ)補(bǔ)好。散落在模板上的混混凝土應(yīng)及時(shí)時(shí)清理干凈,模模板可以周轉(zhuǎn)轉(zhuǎn)使用,但需需保護(hù)好并刷刷脫模劑。6.15冬雨季施施工注意事項(xiàng)項(xiàng)雨量為小雨以上時(shí)時(shí),應(yīng)停止砌砌筑,對(duì)已砌砌筑的墻體宜宜遮蓋,防止止雨水浸入。繼繼續(xù)施工時(shí),應(yīng)應(yīng)復(fù)核墻體的的垂直度。在在雨季施工時(shí)時(shí),砌筑砂漿漿稠度應(yīng)視實(shí)實(shí)際情況適當(dāng)當(dāng)減小,每日日砌筑高度不不宜超過(guò)1..2m。冬季施工時(shí),砌筑筑砂漿使用時(shí)時(shí)的溫度不應(yīng)應(yīng)低于5℃,小砌塊砌砌體不得采用用凍結(jié)法施工工。砌筑砂漿漿應(yīng)用普通硅硅酸鹽水泥拌拌制,不得采采用摻氯鹽的的砂漿施工,不不得使用澆過(guò)過(guò)水或浸水后后受凍的小砌砌塊。構(gòu)造柱在冬期施工工時(shí),要注意意清除模板內(nèi)內(nèi)和磚上的冰冰碴。混凝土土外加劑的選選擇和摻量須須按有關(guān)規(guī)定定確定。對(duì)已已澆好的混凝凝土,要采用用保溫措施,避避免受凍。構(gòu)造柱施工時(shí)應(yīng)有有防雨措施,下下雨時(shí)不宜露露天澆灌混凝凝土。未下雨雨而露天澆灌灌的混凝土也也要及時(shí)覆蓋蓋,以防雨水沖沖刷。要特別別注意根據(jù)露露天料場(chǎng)砂石石含水量的變變化,調(diào)整水水灰比,確保保混凝土的強(qiáng)強(qiáng)度。6.16質(zhì)量控控制要點(diǎn)(1)砌體砌筑要求雙雙面掛線;(2)不允許搭設(shè)單排排架,不準(zhǔn)在在墻體留架子子眼,構(gòu)造柱柱、圈梁澆筑筑不宜留架眼眼,避免架眼眼處封堵不嚴(yán)嚴(yán),造成粉刷刷層空鼓或裂裂縫漏水。構(gòu)構(gòu)造柱采用穿穿墻對(duì)拉筋固固定模板,模模板采用方木木做圍檁,對(duì)對(duì)拉筋采用PUC管套管,拆拆模后可以循循環(huán)使用,嚴(yán)嚴(yán)禁用對(duì)拉鐵鐵絲直接固定定模板,造成成表面不平整整或漏漿嚴(yán)重重。此外沿圈圈梁及構(gòu)造柱柱外沿墻體粘粘貼雙面膠。模模板拼縫嚴(yán)密密,振搗密實(shí)實(shí)。構(gòu)造砼要要求外光內(nèi)實(shí)實(shí),表面達(dá)到到清水砼要求求。(3)墻體預(yù)留圓孔用用Φ10—Φ12圓鋼筋做圓圓形骨架支撐撐,粉刷時(shí)切切去圓箍?jī)?nèi)支支撐,圓箍留留作粉刷層保保護(hù)沿;(4)嚴(yán)格按設(shè)計(jì)和規(guī)規(guī)范要求設(shè)置置拉結(jié)筋,柱柱梁內(nèi)漏設(shè)預(yù)預(yù)留拉結(jié)筋時(shí)時(shí),應(yīng)經(jīng)設(shè)計(jì)計(jì)工代和監(jiān)理理同意后采取取可靠補(bǔ)救措措施;大于或或等于1.5米的窗口下部部,不論設(shè)計(jì)計(jì)要求與否,均均設(shè)置窗臺(tái)梁梁或砌體內(nèi)布布設(shè)通長(zhǎng)2根Φ10圓鋼筋,防防止窗臺(tái)下砌砌體裂縫;(5)砌塊應(yīng)充分濕潤(rùn)潤(rùn)隔夜后砌筑筑;加氣混凝凝土砌塊含水水率應(yīng)控制在在18%以下,砌塊塊存放時(shí)不得得雨淋水泡,砌砌筑前不得大大量澆水濕潤(rùn)潤(rùn),造成流漿漿污染墻面。(6)墻體砌筑頂部需需設(shè)置后砌層層,該層砌體體采用斜磚砌砌筑,一般在在下部墻體完完成間隔一個(gè)個(gè)星期左右開(kāi)開(kāi)始。墻體砌筑質(zhì)質(zhì)量標(biāo)準(zhǔn)和檢檢查方法類別序號(hào)檢查項(xiàng)目質(zhì)量標(biāo)準(zhǔn)單位檢驗(yàn)方法及器具主控項(xiàng)目1磚強(qiáng)度等級(jí)、規(guī)格和和外加劑質(zhì)量量磚強(qiáng)度等級(jí)、規(guī)格和和摻入砂漿中中的外加劑等等必須符合設(shè)設(shè)計(jì)要求和現(xiàn)現(xiàn)行有關(guān)標(biāo)準(zhǔn)準(zhǔn)的規(guī)定檢查磚、外加劑質(zhì)質(zhì)量檢驗(yàn)報(bào)告告和試驗(yàn)報(bào)告告2砂漿品種、強(qiáng)度等等級(jí)砂漿品種、強(qiáng)度等等級(jí)必須符合合設(shè)計(jì)要求和和現(xiàn)行有關(guān)標(biāo)標(biāo)準(zhǔn)的規(guī)定檢查砂漿試塊試驗(yàn)驗(yàn)報(bào)告3斜槎留置承重墻體嚴(yán)禁使用用斷裂磚;磚磚應(yīng)面朝上反反砌于墻上;;墻體轉(zhuǎn)角處處和交接處應(yīng)應(yīng)同時(shí)砌筑,臨臨時(shí)間斷處應(yīng)應(yīng)砌成斜槎,斜斜槎水平投影影長(zhǎng)度不小高高度的2/3觀察檢查4砌體沿高度磚帶及及拉筋必須符合現(xiàn)行有關(guān)關(guān)標(biāo)準(zhǔn)的規(guī)定定觀察和鋼尺檢查5飽滿度水平灰縫≥90%用百格網(wǎng)檢查磚底底面與砂漿的的粘結(jié)痕跡面面積。每處檢檢測(cè)3塊磚,取其其平均值。豎向灰縫≥80%6軸線位移≤10mm用經(jīng)緯儀和鋼尺檢檢查或用其他他測(cè)量?jī)x器檢檢查7垂直度每層≤5mm用2m托線板檢查全高≤10m≤10用經(jīng)緯儀、吊線和和鋼尺檢查,或或用其他測(cè)量量?jī)x檢查>10m≤20一般項(xiàng)目1組砌形式不應(yīng)有通縫、上下下皮錯(cuò)縫長(zhǎng)度度大于1/3磚長(zhǎng),灰縫平平直、均勻、不不透亮觀察和用鋼尺檢查查2預(yù)留洞、預(yù)埋件位置準(zhǔn)確、尺寸符符合設(shè)計(jì)要求求鋼尺檢查3水平灰縫厚度和豎豎縫寬度宜為10mm,但但不應(yīng)大于112mm,也也不應(yīng)小于88mm用鋼尺量5皮磚的的高度和2mm砌體長(zhǎng)度折折算4基礎(chǔ)頂面和樓面標(biāo)標(biāo)高偏差±15mm用水平儀和鋼尺檢檢查5表面平整度清水墻、柱≤5mm用2m靠尺和楔形塞塞尺檢查混水墻、柱、基礎(chǔ)礎(chǔ)≤86門(mén)窗洞口高度寬度度偏差±5mm用鋼尺檢查7外墻上下窗偏移≤20mm以底層窗口為準(zhǔn),用用經(jīng)緯儀或吊吊線檢查8水平灰縫平直度清水墻≤7mm拉10m線和用鋼尺尺檢查渾水墻≤10.5樣板標(biāo)準(zhǔn)(灰砂磚)墻墻體砌筑雙面面掛線墻體洞口加加鋼筋圈墻體洞口效果頂部斜砌做法構(gòu)造柱澆筑效果5.2.2抹灰工工程.1工藝流程墻體水平、垂直度度檢查,線槽槽配電箱等部部位檢查墻面面基層清理澆澆水濕潤(rùn)墻面面找規(guī)矩、做做灰餅、沖筋筋抹底灰抹面灰灰養(yǎng)護(hù).2材料要求及及質(zhì)量標(biāo)準(zhǔn)(1)材料要求材料的品種、質(zhì)量量必須符合設(shè)設(shè)計(jì)要求,抹抹灰質(zhì)量要求求各抹灰層之之間及抹灰層層與基體之間間必須粘結(jié)牢牢固,無(wú)脫層層、空鼓,面面層無(wú)爆灰和和裂縫等缺陷陷。允許偏差項(xiàng)目項(xiàng)目允許偏差(mm)檢驗(yàn)方法1立面垂直3用2000mm脫線線板和尺檢查查2表面平整2用2000mm靠尺和和楔尺檢查3陰陽(yáng)角垂直2用專用陰、陽(yáng)角量量角器檢查4陰陽(yáng)角方正2用200mm方尺和和楔尺檢查(2)質(zhì)量控制及施工要要點(diǎn)1)抹灰工程應(yīng)在砌砌體工程達(dá)到到強(qiáng)度,并干干縮、沉降穩(wěn)穩(wěn)定后進(jìn)行。2)內(nèi)外墻體面積過(guò)過(guò)大時(shí),應(yīng)適適當(dāng)分格,分分格方案及線線條應(yīng)經(jīng)業(yè)主主工程部批準(zhǔn)準(zhǔn),一般采用用黑色塑料條條或鋁制品條條;(3)抹灰工程防止空空鼓和開(kāi)裂的的措施1)抹灰砂漿應(yīng)使用含含泥量低于2%、細(xì)度模數(shù)數(shù)不小于2.5的中粗砂,嚴(yán)嚴(yán)禁使用細(xì)砂砂、石粉、混混合粉;2)混凝土結(jié)構(gòu)基層應(yīng)應(yīng)用人工鑿毛毛或涂刷混凝凝土界面結(jié)合合劑進(jìn)行毛化化處理;基層層為砼時(shí),刮刮素水泥漿一一道;基層為為加氣砼時(shí),宜宜先灑水潤(rùn)濕濕,澆水量以以水分進(jìn)入墻墻體8~10mmm為宜,澆水水后立即刷108膠:水=1:5溶液涂刷一道。3)安排專人封堵墻體體孔洞。封堵堵時(shí),必須清清除孔內(nèi)雜物物并灑水濕潤(rùn)潤(rùn),用潤(rùn)過(guò)水水的磚及防水水砂漿搗實(shí)或或用細(xì)石混凝凝土分層搗實(shí)實(shí);4)抹灰前應(yīng)清除墻面面污物,并提提前一天澆水水濕潤(rùn);5)在兩種不同基體交交接處及墻面面有管線開(kāi)槽槽處,應(yīng)采用用鋼絲網(wǎng)抹灰灰處理,加強(qiáng)強(qiáng)帶與各基體體的搭接寬度度不應(yīng)小于1150mm;;6)陰陽(yáng)角要清晰、順順直、方正;;7)為確保墻面的垂直直、平整,必必須按規(guī)定貼貼餅、沖筋,再再滿刮抹墻面面。沖筋即在在兩灰餅間抹抹出一長(zhǎng)條灰灰埂,其寬度度控制在100cm左右,厚厚度應(yīng)同灰餅餅。沖筋用于于對(duì)抹灰面進(jìn)進(jìn)行控制,因因此一定要嚴(yán)嚴(yán)格按操作要要求進(jìn)行施工工,所有沖筋筋條采用沖豎豎筋。先將墻墻面潤(rùn)濕,在在兩個(gè)灰餅間間由下向上抹抹一層灰,在在抹第二遍灰灰時(shí),要抹成成凸起的八字字形,比灰餅餅高出0.5~1cm,然后后再用刮杠的的兩端貼緊灰灰餅上下搓動(dòng)動(dòng),要搓到使使筋條與灰餅餅齊平為止。所所用的刮杠宜宜采用鋁合金金方通,如發(fā)發(fā)現(xiàn)變形應(yīng)及及時(shí)更換,否否則會(huì)導(dǎo)致沖沖出的筋不平平。沖筋抹完完后就可以抹抹灰,但應(yīng)控控制好沖筋的的軟硬度,如如筋軟,則易易將筋刮壞產(chǎn)產(chǎn)生凸凹現(xiàn)象象,也不宜在在筋太硬時(shí)抹抹灰,否則墻墻面砂漿收縮縮后,會(huì)出現(xiàn)現(xiàn)沖筋高于墻墻面的現(xiàn)象,導(dǎo)導(dǎo)致抹灰面不不平等通病。可可以手壓略有有印跡為宜。底底層灰在灰餅餅、沖筋及門(mén)門(mén)窗護(hù)角做好好后即可進(jìn)行行。按設(shè)計(jì)要要求砂漿抹于于墻面兩沖筋筋之間,要求求底層灰低于于沖筋,待收收水后再進(jìn)行行中層灰,其其厚度以墊平平?jīng)_筋為準(zhǔn),并并使其略高于于沖筋。中層層砂漿抹后用用刮杠按沖筋筋刮平。使用用刮杠時(shí),雙雙手緊握刮杠杠,均勻用力力,由下向上上移動(dòng),并使使木杠前進(jìn)方方向的一邊略略微翹起。對(duì)對(duì)于出現(xiàn)的凹凹陷處補(bǔ)抹上上砂漿,然后后再刮,直至至平直為止。緊緊接著用木抹抹子搓磨一遍遍,使表面平平整密實(shí)。墻墻的陰角,先先用方尺上下下核對(duì)方正情情況,然后用用陰角器上下下抽動(dòng)扯平,使使室內(nèi)四角做做到方正。8)當(dāng)抹灰厚度大于于35mm時(shí),應(yīng)應(yīng)按規(guī)定增加加鋼絲網(wǎng),分分層抹灰;9)抹灰必須分層進(jìn)進(jìn)行,嚴(yán)禁一一遍成活,水水泥沙漿施工工時(shí)每層厚度度宜控制在5-7mm,層層間間隔時(shí)間間不得少于24小時(shí);10)室外溫度低于55℃時(shí),不宜進(jìn)進(jìn)行外墻粉刷刷;11)外墻抹灰基本同同內(nèi)墻,只是是外墻采用的的是水泥砂漿漿打底及罩面面。分格縫按按圖示留設(shè),面面層砂漿做法法:底層砂漿漿抹好后,檢檢查有無(wú)空鼓鼓、開(kāi)裂現(xiàn)象象,若有則剔剔鑿返修,此此外應(yīng)清除塵塵土、灰垢。按按圖彈線分格格,粘分格條條,滴水槽等等,然后抹面面層砂漿。面面層砂漿厚5~8mm,先用用水潤(rùn)濕,抹抹前先薄薄地地刮一層素水水泥漿,使其其與底灰粘牢牢,緊跟著抹抹罩面灰與分分格條抹平,并并用刮杠橫豎豎刮平,木抹抹子搓毛,鐵鐵抹子壓光;;待其表面無(wú)無(wú)明水時(shí),用用海綿蘸水順順豎直方向輕輕刷1~2遍,以保證證面層灰顏色色一致,避免免及減少收縮縮裂縫。分格格條不拆除,形形成分割縫,除除了圖示分割割縫外,色帶帶與主體分縫縫處及滴水槽槽均設(shè)分格條條。13)注意加強(qiáng)灑水養(yǎng)養(yǎng)護(hù)。.3抹灰參考樣樣板機(jī)械拉毛樣樣板加氣混凝土土砌塊滿掛鋼鋼絲網(wǎng)樣本分隔縫樣板墻體罩面灰灰樣板外墻圍護(hù)工程.1安裝工藝流程.2墻面檁托板安裝施施工(1)標(biāo)高、軸線、先對(duì)對(duì)檁托板預(yù)埋埋鐵進(jìn)行復(fù)測(cè)測(cè),根據(jù)業(yè)主主提供的基準(zhǔn)準(zhǔn)點(diǎn)±0.0000,用水準(zhǔn)儀儀復(fù)測(cè)在第一一排預(yù)埋鐵板板上做出標(biāo)記記,用鋼尺根根據(jù)圖紙?jiān)O(shè)計(jì)計(jì)標(biāo)高,確定定出其它檁托托板位置的標(biāo)標(biāo)高,做好施施工記錄。(2)用全站儀進(jìn)行復(fù)測(cè),在在砼柱上確定定檁托板的軸軸線。(3)檁托板焊接,按照照?qǐng)D紙?jiān)O(shè)計(jì)位位置,對(duì)照已已測(cè)量好的位位置按圖施工工,做到準(zhǔn)確確無(wú)誤,焊縫縫及焊條嚴(yán)格格按照鋼結(jié)構(gòu)構(gòu)施工規(guī)范操操作,做好自自檢記錄,由由于墻面頂標(biāo)標(biāo)高在+35.0左右,考考慮到高度及及施工難度,采采用吊籃提升升施工,施工工順序自下而而上,一個(gè)柱柱距完成后,吊吊籃放下來(lái),依依次施工,一一面墻焊接完完成后,再進(jìn)進(jìn)行下道工序序。.3墻面檁條安裝施工工方案(1)因墻面檁條自重較較輕,施工人人員可以在吊吊籃上用滑輪輪提升材料,安安裝時(shí)按圖紙紙及材料編號(hào)號(hào)對(duì)應(yīng)安裝,普普通螺栓的緊緊固嚴(yán)格按照照鋼結(jié)構(gòu)施工工規(guī)范操作。(2)每根檁條安裝好以以后,立即安安裝拉桿并調(diào)整,做到到橫平豎直,吊吊籃走向及施施工方向,自自下而上,從從左到右,依依次施工,做做好施工自檢檢記錄。.4墻面板安裝根據(jù)本工程施工區(qū)區(qū)域和主導(dǎo)風(fēng)風(fēng)向,確定墻墻面彩板鋪設(shè)設(shè)方向。板的的鋪設(shè)方向一一定要逆著主主導(dǎo)方向進(jìn)行行,切忌將板板的方向鋪反反。(1)墻板采用φ5.55*25的自攻釘固固定,自攻釘打在在波谷上,每間隔2500mm打一個(gè)個(gè)自攻釘,將墻面板固固定在檁條上上。(2)打自攻釘時(shí)必須用用力均勻和適適當(dāng),當(dāng)防水水墊圈剛好壓壓緊墻面板時(shí)時(shí),并與自攻攻釘?shù)穆菝毕嘞嗥烬R,即表表示自攻釘已已緊固。(3)根據(jù)檁條安裝的實(shí)實(shí)際位置,再再找出排版圖圖相應(yīng)的墻面面板,在地面面鉆孔,施工工人員在吊籃籃上用滑輪及及繩索提升墻墻板,安裝順順序自下而上上,再由上到到下,依次施施工。(4)在安裝第一張板時(shí)時(shí),用經(jīng)緯儀儀校正,每安安裝五張板墻墻面板時(shí),復(fù)復(fù)測(cè)一下,墻墻面板的垂直直度,做到橫橫平豎直,板板面清潔。(5)由于墻面比較高,墻墻面板由2~3塊搭接施工工,在吊籃上上每次只能打打一排三顆自自攻釘,為確確保墻面板的的垂直度,用用自攻釘緊固固兩端后,再再安裝第二塊塊板,其安裝裝順序?yàn)橄茸宰宰螅ㄓ遥┲林劣遥ㄗ螅蠛笞韵露纤邪邃佂旰螅瑱z檢查安裝平整整度和自攻釘釘?shù)那闆r。.5質(zhì)量控制(1)板材堆放場(chǎng)地為AA排外場(chǎng)地,彩彩板圍護(hù)結(jié)構(gòu)構(gòu)的板材堆放放場(chǎng)地應(yīng)注意意以下幾點(diǎn)::1)板材堆放應(yīng)設(shè)在安安裝點(diǎn)的相近近點(diǎn),避免長(zhǎng)長(zhǎng)距離運(yùn)輸,可可設(shè)在建筑的的周?chē)徒ㄖ?nèi)的場(chǎng)地中中。2)板材宜隨進(jìn)度運(yùn)到到堆放點(diǎn),避避免在工地堆堆放時(shí)間過(guò)長(zhǎng)長(zhǎng),造成板材材不可挽回的的損壞。3)堆放板材的場(chǎng)地旁旁應(yīng)有二次加加工的場(chǎng)地。4)堆放場(chǎng)地應(yīng)平整,不不易受到工程程運(yùn)輸施工過(guò)過(guò)程中的外物物沖擊、污染染、磨損、雨雨水的浸泡。5)按施工順序堆放板板材,同一種種板材應(yīng)放在在一疊內(nèi),避避免不同種類類的疊壓和翻翻倒板材。6)堆放板材應(yīng)設(shè)墊木木或其他承墊墊材料。并應(yīng)應(yīng)使板材縱向向成一傾角放放置,以便雨雨水排出。7)當(dāng)板材長(zhǎng)期不能施施工時(shí),現(xiàn)場(chǎng)場(chǎng)應(yīng)在板材干干燥時(shí)用防雨雨材料覆蓋。(2)安裝放線:1)由于主廠廠房彩板墻面面是預(yù)制裝配配結(jié)構(gòu),故安安裝前的放線線工作對(duì)后期期安裝質(zhì)量起起到保證作用用,不可忽視視。2)安裝放線前應(yīng)對(duì)安安裝面上的主主廠房的建筑筑成品進(jìn)行測(cè)測(cè)量,對(duì)達(dá)不不到安裝要求求的部分提出出修改。對(duì)施施工偏差作出出記錄,并針針對(duì)偏差提出出相應(yīng)的安裝裝措施。3)根據(jù)排板設(shè)計(jì)確定定排板起始線線的位置。主主廠房的墻面面施工中,先先在檁條上標(biāo)標(biāo)定出起點(diǎn),即即沿跨度方向向在每個(gè)檁條條上標(biāo)出排板板起始點(diǎn),各各個(gè)點(diǎn)的連線線應(yīng)與建筑物物的縱軸線相相垂直,而后后在板的寬度度方向每隔幾幾塊板繼續(xù)標(biāo)標(biāo)注一次,以以限制和檢查查板的寬度安安裝偏差積累累。4)墻面安裝完畢后應(yīng)應(yīng)對(duì)配件的安安裝二次放線線,以保證墻墻面板的水平平度和垂直度度。忽視這種種步驟,僅用用目測(cè)和經(jīng)驗(yàn)驗(yàn)的方法,是是達(dá)不到安裝裝質(zhì)量要求的的。(3)彩鋼壓型板的質(zhì)量量驗(yàn)收標(biāo)準(zhǔn)::1)墻面板、收邊板應(yīng)應(yīng)橫平豎直,墻墻面檐口成一一直線,檐口口直線允許偏偏差L/10000mm,板與與板錯(cuò)口應(yīng)≤5mm,彩鋼鋼壓型板長(zhǎng)度度≤10m時(shí),側(cè)側(cè)彎≤5mm,板長(zhǎng)>10m時(shí)側(cè)彎≤20mm。2)板面平整清潔,不不得有嚴(yán)重的的碰撞痕跡和和凹陷等,自自攻螺栓等連連接件應(yīng)成一一直線,不得得有松動(dòng)。收邊板的搭接處必必須滿涂密封封膏,收邊板板與板之間咬咬合應(yīng)緊密,不不得漏咬。3)墻面板面不得有未未經(jīng)處理的孔孔洞。圍護(hù)安裝圖示檁條安裝外墻板安裝裝彩板搭接窗孔側(cè)包角角安裝墻身陽(yáng)角包板及女女兒墻壓板安裝窗臺(tái)泛泛水板嵌縫樓地面工程根據(jù)設(shè)計(jì)圖圖紙要求,零零米汽機(jī)房、6..9m汽機(jī)房房、6.3mm電纜夾層、煤煤倉(cāng)間多數(shù)樓樓層采用彩色色耐磨地坪,配配電間、電子子設(shè)備間采用用防靜電橡膠膠地板,133.7米采用耐磨橡橡膠地板。化水等其余余構(gòu)筑物地面面采用防滑地地磚或細(xì)石混混凝土樓面。.1彩色耐磨地地坪施工流程程工藝流程:基面混混凝土澆注及及表面找平→耐磨硬化劑劑第一次撒布布→第一次機(jī)械械圓盤(pán)抹平→耐磨硬化劑劑第二次撒布布→第二次機(jī)械械圓盤(pán)抹平及及收光→耐磨地面養(yǎng)養(yǎng)護(hù)→耐磨地面切切縫→耐磨地面驗(yàn)驗(yàn)收注意事項(xiàng):1)耐耐磨層施工時(shí)時(shí),同一區(qū)域域應(yīng)暫停其它它設(shè)備安裝和和施工;2)耐磨層完成成區(qū)域3天內(nèi)禁止使使用,7天后可輕載載,28天后可正常常使用;3))交叉施工工時(shí),應(yīng)對(duì)完完工的地坪做做好保護(hù)措施施。施工完畢畢后3-4天內(nèi)必須及及時(shí)切縫并嵌嵌縫,以避免免裂紋產(chǎn)生,嵌嵌縫可避免切切縫處承受反反復(fù)剪切應(yīng)力力產(chǎn)生崩裂。4)撒粉必須均勻(包括第一次60%,第二次40%);撒布耐磨材料后用直尺刮平。5)邊角經(jīng)手工抹刀處理后不可有明顯抹刀痕跡;6)撒粉打磨的施工人員必須穿平底鞋;7)完工后的區(qū)域不可有機(jī)械刀印;8)必須處理好塊與塊之間的接縫,不可有不良點(diǎn);9)養(yǎng)護(hù)劑須均勻涂裝。
耐磨地面質(zhì)量標(biāo)準(zhǔn):主控項(xiàng)目:1)混凝土面層強(qiáng)度等級(jí)不小于C20。2)面層與基層應(yīng)結(jié)合牢固,無(wú)空鼓、裂紋。一般項(xiàng)目:1)面層表面應(yīng)光滑、平整、無(wú)抹紋、無(wú)漏壓。2)面層表面的坡度應(yīng)符合設(shè)計(jì)要求,不得有倒泛水和積水現(xiàn)象。3)偏差項(xiàng)目:表面平整度:2mm;分倉(cāng)縫平直:2mm。耐磨地坪耐磨地坪.2地磚地面施工工(1)基層處理首先對(duì)原有的基底底面進(jìn)行清理理,檢查原始始地面的平整整度。對(duì)整個(gè)個(gè)樓層應(yīng)統(tǒng)一一一個(gè)地面標(biāo)標(biāo)高,并在每每一個(gè)房間和和走道的墻面面的彈線(公公用水平線)下下標(biāo)明地面尺尺寸。(2)材料準(zhǔn)備首先應(yīng)與甲方一起起確定地磚的樣品,并并作出標(biāo)識(shí)。然然后根據(jù)材料料計(jì)劃采購(gòu)。采采購(gòu)后應(yīng)將所所購(gòu)材料報(bào)給給甲方或監(jiān)理理驗(yàn)收。對(duì)不不合格品堅(jiān)決決不用。在鋪鋪貼前應(yīng)將塊塊料浸水晾干干,并檢查每每一塊塊料的的質(zhì)量,對(duì)有有明顯色差、暗暗裂紋和缺棱棱角、對(duì)角差差、平整度等等不符和要求求的堅(jiān)決不用用。砂子、水泥分開(kāi)堆堆放,砂采用用中砂,水泥泥采用425#普通硅酸鹽鹽水泥。砂和和水泥堆放時(shí)時(shí),應(yīng)注意不不能超過(guò)樓板板的允許荷載載。(3)施工方法計(jì)算房間的尺寸、找找中心點(diǎn),拉拉十字線,均均分排板,若若局部塊料不不能均分,要要調(diào)整好鋪貼貼的部位和尺尺寸。鋪貼時(shí)時(shí)從中點(diǎn)向兩兩邊拉線每三三塊磚拉一道道線,根據(jù)地地面標(biāo)高按線線樣施工。采用水泥:砂1::4干硬性水泥泥砂漿鋪平敲敲實(shí),然后在在地磚底面均均勻抹上一層層1cm水灰比比為0.3~0.5純水泥漿再用橡皮錘錘敲實(shí),鋪平平。若發(fā)現(xiàn)空空隙應(yīng)掀起板板塊,補(bǔ)實(shí)砂砂漿后再進(jìn)行行鋪貼。(4)質(zhì)量要求::1)、板材與基層應(yīng)應(yīng)粘接牢固,不不應(yīng)有空鼓。2)、表面整潔、顏顏色一致、接接縫平直、圖圖案拼合自然然。3)、板塊邊角方正正,無(wú)裂紋、無(wú)無(wú)缺角等缺陷陷。、允許偏差及檢驗(yàn)驗(yàn)方法表面平整:允許11mm,用2m靠尺檢查查。縫格平直:允許11mm,拉5m線檢查,不不足5m拉通線。接縫高低差不大與與0.5mmm。(5)成品保護(hù)1)、地磚鋪貼后,不不得用鐵梯子子在上拖動(dòng),若若是鐵活動(dòng)梯梯,則應(yīng)在底底部包上軟包包。2)、不得用利器劃劃傷地磚表面面。3)、嚴(yán)禁在地磚表表面燒焊鐵件件。4)、不得用油性色色彩涂抹到表表面。防滑地磚、花崗巖巖的鋪貼方法法可參照進(jìn)行行。衛(wèi)生間(1)衛(wèi)生間墻面、地面面磚縫對(duì)齊;;潔具中心線線要與磚縫對(duì)對(duì)稱;排磚設(shè)設(shè)計(jì)時(shí)地漏宜宜置于板塊正正中,地板磚磚對(duì)角線裁開(kāi)開(kāi)加工地漏口口,地漏口要要比周邊地板板磚低5mmm;地面找坡0.5-11%,潑水試驗(yàn)驗(yàn)要求地面排排水順暢、不不積水;(2)衛(wèi)生間地地坪、地漏及及防水處理1)衛(wèi)生間間的樓板必須須采用現(xiàn)澆混混凝土,澆注注時(shí)應(yīng)同時(shí)將將周邊墻體除除門(mén)洞口處范范圍以外向上上做一道高度度不小于1220mm的混混凝土翻邊,成成品地坪應(yīng)低低于相鄰房間間20-30mmm;2)過(guò)樓層板管管道孔洞應(yīng)采采取預(yù)留法并并做套管,套套管應(yīng)做止水水環(huán),套管上上沿應(yīng)高出成成品地面300mm以上;;如套管漏裝裝或移位另做做時(shí),應(yīng)將洞洞口清洗干凈凈、毛化處理理、涂刷建筑筑膠液,混凝凝土填塞分兩兩次進(jìn)行:用用摻入適量抗抗裂抗?jié)B作用用微膨脹劑的的細(xì)石混凝土土澆注至套管管擋水圈以上上,凝結(jié)后進(jìn)進(jìn)行4h蓄水試驗(yàn),無(wú)無(wú)滲漏后再填填嵌上部混凝凝土并留置110mm凹面面涂刷防水材材料;3)墊層施施工時(shí),從地地漏口向四周周拉放射線找找坡,坡度為為0.5-11%,地漏口周周?chē)?%的泛水坡度度;4)在做地地板磚前必須須先做一道防防水層,防水水層施工前應(yīng)應(yīng)先將樓板四四周清理干凈凈,陰角及預(yù)預(yù)留孔洞處粉粉成小圓弧。防防水層泛水高高度不得小于于300mmm。施工完畢畢后,應(yīng)進(jìn)行行24h蓄水試驗(yàn),確確保不滲漏。4)衛(wèi)生間間墻面防潮、防防水處理衛(wèi)生間墻墻面粉刷前應(yīng)應(yīng)熱涂一道聚聚胺脂防水涂涂料(高度不不少于1.88m),并隨隨即撒粗砂礫礫便于粉刷層層的結(jié)合,基基層砂漿應(yīng)分分二次刮糙;;5)衛(wèi)生間間門(mén)框下部(與與踢腳線高度度一致)采用用花崗巖制作作,以防腐蝕蝕;6)衛(wèi)生間上水水管道暗敷。衛(wèi)生潔具安裝地磚鋪貼地漏做法、乳膠漆施工工藝藝(1)基層或基基體處理混凝土、抹灰墻面面及頂棚、石石膏板墻及頂頂棚等各種基基層面必須有有足夠的強(qiáng)度度,無(wú)起砂、粉粉化、脫皮、穌穌松、浮土等等現(xiàn)象,基層層表面的浮土土污垢以及其其他附著雜物物均應(yīng)清除干干凈,然后用用1:2.5水泥砂漿修修補(bǔ)基層或基基體上的缺棱棱掉角及孔洞洞,并用膩?zhàn)幼訉?duì)表面麻面面及縫隙進(jìn)行行填補(bǔ)平整,干干燥后用砂紙紙磨光,擦凈凈浮灰。(2)膩?zhàn)訙?zhǔn)備備乳膠漆工程采用的的膩?zhàn)討?yīng)與基基層、基體和和乳膠漆面層層的性能相配配套,膩?zhàn)拥牡乃苄院鸵淄客啃詰?yīng)滿足施施工要求,干干燥后應(yīng)與基基層或基體粘粘結(jié)牢固,無(wú)無(wú)粉化、起皮皮和裂紋現(xiàn)象象。混凝土、抹灰內(nèi)墻墻、頂棚表面面用膩?zhàn)影兹槟z1.55雙灰粉52%羧甲基纖維素溶液液(即化學(xué)漿漿糊)3.5(3)滿刮膩?zhàn)幼尤椋旱谝灰槐闈M刮膩?zhàn)幼右髾M向批批刮平整、均均勻、光滑、密密實(shí)、線角及及邊棱整齊,并并盡量刮薄,不不得漏刮,接接頭無(wú)留槎,待待完全干燥后后,用粗砂紙紙磨平整、光光潔、擦清浮浮灰。然后第第二遍、第三三遍滿刮膩?zhàn)幼樱捎猛瑯訕臃椒ㄟM(jìn)行施施工,但批刮刮方向應(yīng)垂直直方向批刮平平整,不得漏漏批刮,待完完全干燥后用用細(xì)砂紙打磨磨,手感目測(cè)測(cè)平整、光滑滑為止。(陰陰陽(yáng)角處理)(4)滾涂和刷刷涂乳膠漆1)、待封底層完全全干燥后,并并經(jīng)磨光、擦擦清后,才可可滾涂和刷涂涂乳膠漆。2)、滾涂乳膠漆::采用兩只專專用滾筒,一一只滾筒均勻勻沾上稀釋均均化的乳膠漆漆,在基層表表面先水平方方向一個(gè)方向向滾涂第一遍遍,另一只滾滾筒(不沾乳乳膠漆)重復(fù)復(fù)上述操作,達(dá)達(dá)到均勻,待待干燥(約6h)后,用細(xì)細(xì)砂紙打磨光光潔,擦清浮浮灰,特別是是棱角處要清清晰整齊,不不得堆積乳膠膠漆,質(zhì)量符符合要求后,再再垂直方向滾滾涂第二遍,用用另一只滾筒筒(不沾乳膠膠漆)重復(fù)上上述操作,達(dá)達(dá)到均勻滾筒筒切勿往返滾滾動(dòng)。3)、刷涂乳膠漆::用毛刷或短短刷沾上乳膠膠漆,先水平平方向一個(gè)方方向涂刷第一一遍,每次涂涂刷長(zhǎng)度應(yīng)均均勻一致,注注意漏刷、透透底,待干燥燥約6h)后,用細(xì)細(xì)砂紙打磨光光潔,并用濕濕布擦清,再再垂直方向涂涂刷第二遍,每每次涂刷長(zhǎng)度度應(yīng)均勻一致致,刷面均勻勻一致,無(wú)刷刷紋、流墜、透透底等現(xiàn)象。輕鋼龍骨石膏板吊吊頂(1)準(zhǔn)備工作1)在網(wǎng)架節(jié)點(diǎn)上,按按設(shè)計(jì)要求設(shè)設(shè)置吊桿;2)吊頂內(nèi)的燈槽、水水電管道及上上人吊頂內(nèi)的的人行或安裝裝通道,應(yīng)安安裝完畢,消消防管道安裝裝并試壓完畢畢;3)吊頂內(nèi)的燈槽、斜斜撐、剪刀撐撐等,應(yīng)根據(jù)據(jù)工程情況適適當(dāng)布置,輕輕型燈具應(yīng)吊吊在主龍骨或或附加龍骨上上,重型燈具具或電扇不得得與吊頂龍骨骨連接,應(yīng)另另設(shè)吊鉤。(2)材料要求1)吊頂龍骨在運(yùn)輸輸安裝時(shí),不不得扔摔、碰碰撞,龍骨應(yīng)應(yīng)平放,防止止變形,龍骨骨要放在室內(nèi)內(nèi),防止生銹銹;2)石膏板在運(yùn)輸安安裝時(shí)應(yīng)輕放放,不得破壞壞板材的表面面和邊角,應(yīng)應(yīng)防止受潮變變形,放于平平整、干燥、通通風(fēng)處。(3)龍骨安裝1)根據(jù)吊頂?shù)脑O(shè)計(jì)計(jì)標(biāo)高在四周周墻上或柱子子上彈線,彈彈線應(yīng)清楚,位位置應(yīng)準(zhǔn)確,其其水平允許偏偏差±5mm。2)主龍骨吊頂間距距,應(yīng)按設(shè)計(jì)計(jì)推薦系列選選擇,中間部部分應(yīng)起拱,金金屬龍骨起拱拱高度應(yīng)不小小于房間短向向跨度的1/200,主龍骨安安裝后應(yīng)及時(shí)時(shí)校正其位置置和標(biāo)高。3)吊桿距主龍骨端端部不得超過(guò)過(guò)300㎜,否則應(yīng)應(yīng)增設(shè)吊桿,以以免主龍骨下下墜,當(dāng)?shù)鯒U桿與設(shè)備相遇遇時(shí),應(yīng)調(diào)整整吊點(diǎn)構(gòu)造或或增設(shè)角鋼過(guò)過(guò)橋,以保證證吊頂質(zhì)量。4)對(duì)于檢修孔、通通風(fēng)部位,在在安裝龍骨的的同時(shí),將其其尺寸位置留留出,將橫撐撐龍骨安裝完完畢。5)次龍骨應(yīng)貼緊主主龍骨安裝,當(dāng)當(dāng)用自攻螺絲絲安裝板材時(shí)時(shí),板材的接接縫處,必須須安裝在寬度度不小于40mm的次次龍骨上。6)全面校正主、次次龍骨的位置置及其水平度度,連接件應(yīng)應(yīng)錯(cuò)開(kāi)安裝,明明龍骨應(yīng)目測(cè)測(cè)無(wú)明顯彎曲曲,通長(zhǎng)次龍龍骨連接處的的對(duì)接錯(cuò)位偏偏差不超過(guò)22mm,校正正后應(yīng)將龍骨骨的所有吊掛掛件、連接件件擰緊。(4)石膏板安裝1)板材應(yīng)在自由狀狀態(tài)下進(jìn)行固固定,防止出出現(xiàn)彎棱、凸凸鼓現(xiàn)象,石膏板的長(zhǎng)長(zhǎng)邊沿縱向次次龍骨鋪設(shè)。2)自攻螺釘與紙面面石膏板邊距距離,面板包包封的邊以10~15mm為宜宜,切割板的的邊以15~20mm為宜宜。3)固定石膏板的次次龍骨間距一一般不大于4400mm,在在南方潮濕地地區(qū),間距應(yīng)應(yīng)相應(yīng)減少,以以300mmm為宜。4)釘距以150~~170mmm為宜,螺釘釘應(yīng)垂直,彎彎曲、變形的的螺釘應(yīng)剔除除,并在相隔隔50cm的部部位另安螺釘釘。5)安裝雙層石膏板板時(shí),面層板板與基層板的的接縫應(yīng)錯(cuò)開(kāi)開(kāi),不得在同同一根龍骨上上接縫。6)紙面石膏板與龍龍骨固定,應(yīng)應(yīng)從一塊板的的中間向板的的四邊固定,不不得多點(diǎn)同時(shí)時(shí)作業(yè)。7)螺絲宜埋入紙面面2-3mm并不不破壞紙面,釘釘眼應(yīng)作除銹銹處理,并用用石膏膩?zhàn)幽ㄆ健?)頂棚板縫處理工工藝:先用嵌嵌縫石膏膩?zhàn)幼庸纹剑骶W(wǎng)網(wǎng)格布一道,刷刷乳膠一道,貼貼嵌縫紙帶一一道。(5)質(zhì)量評(píng)定驗(yàn)收1)石膏板與龍骨應(yīng)應(yīng)連接緊密,表表面應(yīng)平整,不不得有污染、折折裂、缺棱掉掉角、錘傷等等缺陷,連接接應(yīng)均勻一致致,粘貼的面面板不得有脫脫層。2)表面平整度允許許偏差3mmm,接縫高低低允許偏差11mm。墻面鑲貼瓷磚工藝藝(1)基層處理在抹底找平之前需需將基層表面面的浮土,砂砂漿疙瘩、油油污等清理干干凈,洞孔補(bǔ)補(bǔ)好,高出鑿鑿平,如為混混凝土基層應(yīng)應(yīng)鑿毛。(2)底層找平將磚面澆水濕潤(rùn)后后,用1:3水泥砂漿按按標(biāo)筋高度或或標(biāo)志抹平,用用木搓板壓實(shí)實(shí),厚度約為為10-12mm。(3)排磚彈線待找平層砂漿干至至六七成,即即可根據(jù)磚的的尺寸和鑲貼貼施工面積在在找平層上進(jìn)進(jìn)行分段分格格排磚彈線。在在同一墻面上上的磚塊橫豎豎排列,均不不得有一以上上的非整磚,且且只能排在次次要部位或不不顯眼醒目處處。(4)鑲貼鑲貼面磚以前,磚磚墻面要提前前浸濕好,瓷瓷磚要在施工工前浸水,浸浸水時(shí)間不得得小于兩個(gè)小小時(shí),然后取取出涼至手按按磚背無(wú)水跡跡方可貼磚。鑲磚用1:1水泥泥砂漿,使用用水泥不得低低于P32.5的普通硅酸酸鹽水泥,砂砂子為細(xì)砂(過(guò)過(guò)篩),施工工溫度最低在在5度以上,在在磚背面滿抹抹灰漿,四角角刮成斜平面面,厚度約55mm左右,注注意邊角滿漿漿。瓷磚就位位后用灰匙木木柄輕輕擊磚磚面,使之與與鄰面平。粘粘貼8-10塊,用靠尺尺板檢查表面面平整度并用用灰匙將縫撥撥直。(5)擦縫待面磚貼好244小時(shí)后,用用白水泥漿涂涂滿縫隙,再再用棉紗頭蘸蘸漿將縫隙擦擦平實(shí)。水電暖通安裝(1)消防箱安裝:應(yīng)考考慮安裝位置置和朝向便于于操作,且不不影響人員通通行和箱門(mén)開(kāi)開(kāi)啟。固定螺螺栓安裝在箱箱內(nèi),開(kāi)孔應(yīng)應(yīng)采用機(jī)械開(kāi)開(kāi)孔,嚴(yán)禁采采用氣割法開(kāi)開(kāi)孔。(2)空調(diào)通風(fēng)管道安裝裝:通風(fēng)管外外露部分刷涂涂料,保證外外觀效果,法法蘭、螺栓處處刷白漆,鐵鐵皮風(fēng)管保溫溫層外裹鋁箔箔層。(3)照明配管:管卡固固定采用膨脹脹螺栓,管卡卡固定間距、標(biāo)標(biāo)高一致,成成排鋼管焊接接應(yīng)焊管卡內(nèi)內(nèi)部,自制鋼鋼管卡端頭應(yīng)應(yīng)采用弧角。墻體開(kāi)槽嚴(yán)禁直接打鑿造成墻體粉刷空鼓,應(yīng)用手砂輪切割機(jī)開(kāi)縫,然后打鑿。(4)配電箱安裝:各標(biāo)標(biāo)志用彩色打打印回路標(biāo)簽簽,插座面板板上用不同顏顏色標(biāo)明零線線、火線、接接地線。(5)燈具安裝:同一房房間燈具順直直一條線,高高低一個(gè)平,燈燈具與吊頂密密合,同組開(kāi)開(kāi)關(guān)高低差≤0.5mmm,總體布置置保證造型美美觀。(6)管道支架、托架及及吊筋:統(tǒng)一一制作、統(tǒng)一一規(guī)劃,角楞楞打圓,除凈凈銹后刷紅丹丹防銹漆,然然后運(yùn)至現(xiàn)場(chǎng)場(chǎng)安裝,安裝裝后支架及托托架再刷兩道道罩面漆。無(wú)無(wú)吊頂房間的的吊筋要套PVC管裝飾。支支架、托架固固定如采用膨膨脹螺栓,膨膨脹螺栓應(yīng)用用平頭膨脹螺螺栓(7)上下水、消防、暖暖氣等管道及及衛(wèi)生器具安安裝:上下水、消防、暖暖氣等管道穿穿越樓層板和和墻體時(shí)均應(yīng)應(yīng)預(yù)設(shè)套管,套套管的坐標(biāo)位位置要正確;;套管內(nèi)用油油麻填塞、油油膏封口;穿越樓層板的鋼套套管要用車(chē)床床加工倒角,上上口要高出建建筑層面300mm;套管管外露地面以以上部分刷紅紅丹防銹漆和和面漆。現(xiàn)澆樓層板的套管管在混凝土中中部應(yīng)設(shè)擋水水圈,管壁光光滑時(shí)應(yīng)做毛毛化處理:涂涂膠、噴灑中中粗砂。樓層板預(yù)留孔洞后后置法安裝套套管詳見(jiàn)衛(wèi)生生間過(guò)樓層板板管道套管安安裝法;穿墻套管要由兩根根短管組成,并并加工坡口,抹抹灰時(shí)注意調(diào)調(diào)整,使套管管在墻面兩側(cè)側(cè)齊平。b、+0.55m以上穿越越建筑物外墻墻的所有管道道在墻體外側(cè)側(cè)均應(yīng)設(shè)擋水水圈滴水,防防止雨水污染染外墻面。c、上下水管管道安裝要橫橫平豎直,外外露絲扣不超超過(guò)三扣,鉛鉛油麻絲(或或防水膠布)不不準(zhǔn)有“胡子”。下水管道道坡度符合設(shè)設(shè)計(jì)規(guī)定,焊焊口要打磨并并防腐。閥門(mén)門(mén)、暖氣片要要逐個(gè)打壓,做做強(qiáng)度和氣密密性檢驗(yàn)。d、衛(wèi)生器具具如大便器、水水箱、洗手池池等安裝規(guī)范范,高低及位位置要符合設(shè)設(shè)計(jì)要求。e、管道過(guò)地地板磚、墻面面磚安裝時(shí)應(yīng)應(yīng)盡可能居板板中,依實(shí)測(cè)測(cè)尺寸,在地地板磚或墻面面磚上放樣,用用鉆割圓孔,然然后鋸割一分分為二進(jìn)行粘粘貼。幾組室內(nèi)管道底部部處理圖管道穿墻處加墊圈圈電纜溝、排水溝蓋蓋板(1)室內(nèi)外溝道要平直直,溝底坡度度符合設(shè)計(jì)要要求,排水順順暢、措施可可靠;(2)溝沿及蓋板周邊均均須設(shè)置熱鍍鍍鋅角鋼保護(hù)護(hù)(無(wú)論設(shè)計(jì)計(jì)要求與否)為為節(jié)約鋼材,溝溝沿角鋼可反反扣向溝壁混混凝土內(nèi),但但角鋼選材不不宜小于30×300×3mmm;蓋板角鋼鋼下部粘貼橡橡膠板,避免免蓋板與溝沿沿接觸不緊密密、晃動(dòng);蓋蓋板上表面與與溝沿上口應(yīng)應(yīng)平齊一致;;蓋板面層應(yīng)應(yīng)與地面裝飾飾標(biāo)準(zhǔn)一致;;蓋板蓋上后后,要平整、穩(wěn)穩(wěn)固,蓋板與與蓋板、蓋板板與角鋼之間間縫隙要做到到基本密合。具具體做法附圖圖執(zhí)行。(3)樓板孔洞鋼格柵板板(或玻璃鋼鋼格柵板)安安裝,溝沿做做法應(yīng)參照上上述要求。(4)室內(nèi)溝道蓋板應(yīng)按按嵌入式施工工,室外溝蓋蓋板可按外壓壓式施工。(5)溝蓋板在集中拌拌和站預(yù)制,定定制專用不銹銹鋼溝蓋板模模具,角鋼面面涂防腐漆一一道,銀粉漆漆一道。室外電纜溝組圖屋面防水施工(1)簡(jiǎn)況本工程采用防水卷卷材防水,屋屋面按上人保保溫屋面(由由下到上)做做法:混凝土土現(xiàn)澆板---220厚1∶3水泥砂漿找找平層(分縫縫)---刷基層處理理劑一遍---兩層3.0厚SBS改性瀝青防防水卷材,配配套粘貼劑粘粘貼---25厚擠塑聚苯苯乙烯保溫隔隔熱板---面層40厚C30細(xì)石砼內(nèi)配4@150,分格縫6m×6m。所有防水材料均由由專業(yè)隊(duì)伍負(fù)負(fù)責(zé)施工,防防水材料進(jìn)場(chǎng)場(chǎng)應(yīng)抽檢合格格方可使用。防防水卷材屋面面,其屋面水水泥砂漿找平平層嚴(yán)格控制制平整度。施施工前,基層層應(yīng)堅(jiān)實(shí)、平平整,不得有有突出的尖角角和凹坑,表表面不起砂,轉(zhuǎn)轉(zhuǎn)角處應(yīng)做成成圓弧形,為為保證施工質(zhì)質(zhì)量,應(yīng)在+5~+35℃氣溫下施工工。(2)防水卷材施工方方法防水卷材施工前應(yīng)應(yīng)對(duì)近期天氣氣情況進(jìn)行了了解,保證施施工過(guò)程中避避免雨水天氣氣的干擾。施施工前對(duì)驗(yàn)收收合格的基層層進(jìn)行全面清清掃干凈,做做到施工部位位不存有泥、砂砂、油污等影影響卷材與基基層粘接強(qiáng)度度的雜物、污污物。對(duì)施工工部位涂刷基基層處理劑,要要求使用長(zhǎng)把把滾刷將須施施工的基層全全部涂刷處理理劑,局部不不易滾刷的部部位用小刷進(jìn)進(jìn)行刷涂,涂涂刷完成后應(yīng)應(yīng)保證基層不不露白底。下下道工序必須須在底膠完全全干燥后再進(jìn)進(jìn)行施工。卷材施工前應(yīng)先對(duì)對(duì)基層的干燥燥程度進(jìn)行簡(jiǎn)簡(jiǎn)易檢測(cè),將將1m2卷材平平坦地干鋪在在找平層上,靜靜置3~4小時(shí)后掀開(kāi)開(kāi)檢查覆蓋部部位與卷材面面是否有水印印,如無(wú)即可可鋪設(shè)。防水水層做時(shí)首先先對(duì)陰陽(yáng)角、水水落口、出屋屋面管道、屋屋面設(shè)施下部部等特殊部位位加鋪一道附附加層。屋面面卷材的粘貼貼應(yīng)從流水坡坡度的下坡口口開(kāi)始,彈出出標(biāo)準(zhǔn)線,使使卷材的長(zhǎng)向向與流水坡度度方向垂直。粘粘貼卷材前,應(yīng)應(yīng)先將其鋪展展在干凈的基基層上,用長(zhǎng)長(zhǎng)把滾刷蘸專專用粘結(jié)劑在在卷材上涂刷刷;同時(shí)對(duì)基基層采用同樣樣的粘結(jié)劑進(jìn)進(jìn)行刷涂。使使用前應(yīng)待卷卷材和基層的的粘結(jié)劑晾至至基本干燥后后(以不粘手手為宜),才才能進(jìn)行鋪貼貼。鋪貼卷材時(shí),應(yīng)將將卷材的一端端粘貼固定在在預(yù)定的部位位,再沿彈出出的標(biāo)準(zhǔn)線向向前鋪展卷材材,隔一米左右對(duì)標(biāo)標(biāo)準(zhǔn)線進(jìn)行調(diào)調(diào)整,對(duì)線鋪鋪貼。鋪貼過(guò)過(guò)程中最好能能逐步對(duì)粘結(jié)結(jié)上的卷材進(jìn)進(jìn)行壓實(shí)處理理,徹底排除除卷材與基層層之間的空氣氣,鋪完一卷卷后應(yīng)對(duì)完成成粘結(jié)的卷材材進(jìn)行檢查,不不得有空鼓、起起泡等現(xiàn)象。鋪鋪貼防水卷材材時(shí),必須自自然鋪貼,絕絕不允許人工工用力將拉力力施加于卷材材的任何方向向上。搭接完成后,卷材材間接縫口應(yīng)應(yīng)用專用密封封材料進(jìn)行封封邊處理,要要求接縫口封封邊后必須嚴(yán)嚴(yán)密、均勻,不不得露出底色色且寬度不得得小于10mmm。(3)細(xì)部要求屋面防水細(xì)部工藝藝要求:①在屋面的陰陽(yáng)角角、水落口周周?chē)拔菝嬖O(shè)設(shè)施下部等處處要增加一層層卷材附加增增強(qiáng)層,對(duì)于于卷材泛水收收頭處應(yīng)固定定牢固,用密密封膠封嚴(yán)。水水落口周?chē)?500mm范范圍內(nèi)坡度不不應(yīng)小于5%。②密封材料在金屬屬基層上應(yīng)用用耐高溫、耐耐久性好的9030系列如硅酮酮密封膏,對(duì)對(duì)于砼及水泥泥制品基層上上則采用聚氯氯乙烯膠泥。③伸出屋面的管道道四周抹找平平層時(shí)應(yīng)做成成圓錐臺(tái),并并增設(shè)柔性防防水層,并加加大排水坡度度。管道四周周的找平層上上預(yù)留20×20mmm凹槽,內(nèi)內(nèi)填密封材料料。上口宜用用管箍箍緊,密密封材料封口口嚴(yán)密。④防水卷材的接頭頭應(yīng)相互錯(cuò)開(kāi)開(kāi)300mmm以上,以避避免卷材接頭頭處多層卷材材相互重疊而而粘結(jié)不實(shí)成成為漏源;上上下層卷材鋪鋪貼時(shí)長(zhǎng)邊縫縫還應(yīng)錯(cuò)開(kāi)1/3幅寬的卷材材,以避免卷卷材鋪貼不平平而導(dǎo)致局部部積水滲漏。低跨屋面落水口處處加設(shè)鋼筋混混凝土承水簸簸箕(板)或或特制水簸箕箕,防集中水水流沖刷。屋面支架底部做法法衛(wèi)生間屋面排氣管管做法出屋面管道底部施施工門(mén)窗工程施工本工程門(mén)窗工程,一一般門(mén)窗采用用本色鋁合金金,窗采用80系列,門(mén)采采用100系列。其他他特種門(mén)窗有有隔聲門(mén)窗、防防火門(mén)窗,設(shè)設(shè)備進(jìn)出及檢檢修要求的大大門(mén)采用鋼質(zhì)質(zhì)電動(dòng)卷簾門(mén)門(mén),外墻門(mén)采采用復(fù)合(雙雙面)鋼板門(mén)門(mén)。電氣配電室及電纜纜夾層的門(mén)安安裝可以用同同把鑰匙開(kāi)啟啟的球形門(mén)鎖鎖。門(mén)窗工程的施工方方法及措施如如下:門(mén)窗安裝應(yīng)預(yù)留洞洞口,嚴(yán)禁邊邊安裝邊砌墻墻,施工中應(yīng)應(yīng)及時(shí)清理門(mén)門(mén)窗表面的水水泥砂漿,保保護(hù)表面質(zhì)量量。鋁合金的的制作安裝前前先需放線,檢檢查預(yù)留洞口口的幾何形狀狀,預(yù)埋件的的位置是否符符合要求,窗窗框的加工尺尺寸要依照實(shí)實(shí)際洞口尺寸寸,同一立面面的窗的水平平與垂直方向向要做到整齊齊一致。彈好好位置線后,將將門(mén)窗框用木木楔臨時(shí)固定定,門(mén)窗框立立直,上下位位置符合要求求,然后再用用射釘將鍍鋅鋅錨固定在構(gòu)構(gòu)件上,錨固固板門(mén)距離不不大于5000mm,然后后填縫并壓光光、拉毛。鋁鋁合金窗裝入入洞口應(yīng)橫平平豎直,外框框與洞口應(yīng)彈彈性連接牢固固。橫向及豎豎向組合時(shí),應(yīng)應(yīng)采取套插,搭搭接成曲面結(jié)結(jié)合,搭接長(zhǎng)長(zhǎng)度為10mm,油膏密密封。密封條條安裝時(shí)應(yīng)留留有超過(guò)裝配配長(zhǎng)度20-30mm的伸縮余余量,轉(zhuǎn)角處處應(yīng)斜面斷開(kāi)開(kāi),用膠粘劑劑粘貼牢固。鋁鋁合金門(mén)窗安安裝與洞口的的空隙,應(yīng)用用礦棉條或或或玻璃棉氈條條分層填塞,縫縫隙表面留5~8mm深的槽口,填填塞密封材料料或打上密封封膠。防火門(mén)的材料安裝裝都要有產(chǎn)品品合格證和質(zhì)質(zhì)保書(shū)。門(mén)的的安裝應(yīng)按設(shè)設(shè)計(jì)圖紙要求求分清向內(nèi)或或向外開(kāi)啟形形式及左手或或右手開(kāi)啟,門(mén)門(mén)裝入洞口后后用木楔固定定,調(diào)整水平平及垂直度,并并用砂漿嵌填填縫隙密實(shí)。7施工質(zhì)量保證證措施7.1施工質(zhì)質(zhì)量保證體系系、檢查監(jiān)督督機(jī)構(gòu)及控制制措施和手段段施工質(zhì)量的控制措措施和手段(1)施工方案及技術(shù)術(shù)交底由項(xiàng)目總工程師根根據(jù)施工的實(shí)實(shí)際情況確定定是否需要編編制技術(shù)文件件,當(dāng)項(xiàng)目總總工程師根據(jù)據(jù)作業(yè)人員的的技能、培訓(xùn)訓(xùn)和特定施工工過(guò)程的控制制復(fù)雜程度,確確認(rèn)當(dāng)沒(méi)有形形成文件的程程序就不能保保證質(zhì)量或安安全時(shí),確定定編制專用的的技術(shù)文件(包包括作業(yè)指導(dǎo)導(dǎo)書(shū)、施工方方案、施工措措施、專項(xiàng)性性或?qū)I(yè)性施施工組織設(shè)計(jì)計(jì)、管理規(guī)定定、作業(yè)流程程等)。由項(xiàng)目總工程師安安排人員編制制,并經(jīng)相關(guān)關(guān)部門(mén)會(huì)簽。分分管該項(xiàng)目的的副經(jīng)理負(fù)責(zé)責(zé)審核。由項(xiàng)項(xiàng)目總工程師師負(fù)責(zé)技術(shù)文文件的審查,對(duì)對(duì)其技術(shù)的可可行性負(fù)責(zé)。最最后經(jīng)項(xiàng)目經(jīng)經(jīng)理批準(zhǔn)。項(xiàng)目?jī)?nèi)部審批完成成后,按監(jiān)理理單位要求,報(bào)報(bào)監(jiān)理單位審審查。對(duì)專項(xiàng)作作業(yè)進(jìn)行技術(shù)術(shù)交底,要求求全員交底。(2)供貨與包包裝、運(yùn)輸、貯貯存依據(jù)工程設(shè)計(jì)所選選定的材料,編編制采購(gòu)計(jì)劃劃,并根據(jù)質(zhì)質(zhì)量管理內(nèi)控控文件,對(duì)外外購(gòu)材料實(shí)行行樣品制。無(wú)論接貨、發(fā)運(yùn)均均辦理交接手手續(xù),交驗(yàn)收收各項(xiàng)內(nèi)容。接接貨時(shí)對(duì)損壞壞的產(chǎn)品進(jìn)行行記錄或照相相,對(duì)發(fā)運(yùn)時(shí)時(shí)可能出現(xiàn)的的隱患問(wèn)題進(jìn)進(jìn)行事先消除除。無(wú)表面保保護(hù)產(chǎn)品或應(yīng)應(yīng)箱裝而無(wú)箱箱的產(chǎn)品不得得發(fā)運(yùn)且拒絕絕接收。材料或半成品構(gòu)件件應(yīng)貯存在通通風(fēng)干燥的庫(kù)庫(kù)房中,避免免與酸、堿等等腐蝕性物質(zhì)質(zhì)接觸。材料料要分區(qū)擺放放,明確標(biāo)識(shí)識(shí)。(3)廠內(nèi)加工生產(chǎn)工人按操作規(guī)規(guī)程加工零件件,組裝半成成品,實(shí)施質(zhì)質(zhì)量控制,生生產(chǎn)過(guò)程中實(shí)實(shí)施自檢、班班組互檢、質(zhì)質(zhì)檢員抽檢三三級(jí)管理。質(zhì)質(zhì)檢人員對(duì)加加工工序進(jìn)行行監(jiān)督檢查,并并及時(shí)解決和和糾正加工中中存在的問(wèn)題題。(4)組織技術(shù)質(zhì)量教教育在工程過(guò)程中開(kāi)展展以創(chuàng)優(yōu)工程程活動(dòng)為中心心的質(zhì)量教育育活動(dòng),認(rèn)真真貫徹執(zhí)行有有關(guān)施工質(zhì)量量要求及規(guī)范范要求,并對(duì)對(duì)在保證工程程質(zhì)量上有突突出成績(jī)的班班組及個(gè)人給給予獎(jiǎng)勵(lì),對(duì)對(duì)出現(xiàn)質(zhì)量事事故者嚴(yán)懲不不怠。為保證項(xiàng)目質(zhì)量得得到最有效的的控制,在正正式安裝之前前,將在現(xiàn)場(chǎng)場(chǎng)環(huán)境位置安安裝單元樣板板,對(duì)樣板效效果進(jìn)行比較較質(zhì)評(píng)。對(duì)現(xiàn)場(chǎng)材料嚴(yán)格把把關(guān),按有關(guān)關(guān)制度程序化化操作,杜絕絕使用質(zhì)量不不合格的產(chǎn)品品。現(xiàn)場(chǎng)施工推行工序序間質(zhì)量控制制辦法,即中中間檢驗(yàn)。建立質(zhì)量管理網(wǎng)絡(luò)絡(luò),嚴(yán)格遵循循三級(jí)質(zhì)檢制制度。(5)工程質(zhì)量驗(yàn)收1)本工程質(zhì)量及技術(shù)術(shù)要求以會(huì)簽簽的設(shè)計(jì)圖紙紙為準(zhǔn),凡圖圖紙末注明的的,按國(guó)家、行行業(yè)及企業(yè)標(biāo)標(biāo)準(zhǔn)執(zhí)行。2)施工中完善各種質(zhì)質(zhì)量驗(yàn)收手續(xù)續(xù),認(rèn)真填寫(xiě)寫(xiě)各種原始記記錄和質(zhì)量驗(yàn)驗(yàn)收表格。3)工程整體交工驗(yàn)收收時(shí)整理完整整的竣工圖(包包括設(shè)計(jì)變更更通知書(shū),工工程洽商記錄錄、修改圖等等)。7.2材料進(jìn)場(chǎng)和和二次檢驗(yàn)制制度現(xiàn)場(chǎng)材料員負(fù)責(zé)制制定材料的檢檢驗(yàn)控制辦法法,負(fù)責(zé)材料料驗(yàn)收,清點(diǎn)點(diǎn)、過(guò)秤、測(cè)測(cè)量、二次檢檢驗(yàn)以及保存存等。進(jìn)入現(xiàn)場(chǎng)的材料、半半成品、成品品及配件都應(yīng)應(yīng)具有材料合合格證、質(zhì)量量保證書(shū)、生生產(chǎn)廠家、產(chǎn)產(chǎn)品試驗(yàn)報(bào)告告等。帶有技術(shù)性的材料料應(yīng)由材料員員會(huì)同施工員員、質(zhì)量檢查查員共同檢查查把關(guān)。由甲方提供材料由由材料員負(fù)責(zé)責(zé)登記、驗(yàn)收收,并要求供供貨商提供產(chǎn)產(chǎn)品合格證及及檢驗(yàn)報(bào)告。由甲方提供的材料料由材料員對(duì)對(duì)其規(guī)格、質(zhì)質(zhì)量、數(shù)量、提提供時(shí)間、記記錄標(biāo)識(shí)。不合格的材料不得得進(jìn)入施工現(xiàn)現(xiàn)場(chǎng),發(fā)現(xiàn)不不合格的材料料由采購(gòu)人員員負(fù)責(zé)退回供供料單位。由于使用不合格的的材料。造成成質(zhì)量返工或或影響產(chǎn)品質(zhì)質(zhì)量。所返工工造成的損失失由有關(guān)責(zé)任任人賠付。材料發(fā)放必須由材材料員辦理出出庫(kù)手續(xù),注注明材料名稱稱、規(guī)格、數(shù)數(shù)量、計(jì)量單單位、用途及及領(lǐng)料日期,由由領(lǐng)用人簽名名方可發(fā)放。主要建筑裝飾材料料、大宗裝飾飾材料必須先先取樣,經(jīng)有有關(guān)人員及部部門(mén)認(rèn)證后,再再按樣品采購(gòu)購(gòu),不符合原原樣品的材料料不得采購(gòu)。材料復(fù)查、審核中中,必須注意意在已有的材材質(zhì)證件的條條件下,按標(biāo)標(biāo)準(zhǔn)規(guī)定取樣樣復(fù)試。7.4工序質(zhì)量量控制措施和和自檢、自控控措施工序質(zhì)量是產(chǎn)品質(zhì)質(zhì)量的基礎(chǔ),產(chǎn)產(chǎn)品質(zhì)量是“生產(chǎn)者質(zhì)量”,因此在施施工過(guò)程中嚴(yán)嚴(yán)格控制各道道工序質(zhì)量,是是把住質(zhì)量關(guān)關(guān)的前題。嚴(yán)嚴(yán)格要求執(zhí)行行前道工序應(yīng)應(yīng)本著“下道工序就就是用戶”的原則,保保證每道工序序的質(zhì)量,才才能使最后完完工的產(chǎn)品達(dá)達(dá)到質(zhì)量標(biāo)準(zhǔn)準(zhǔn)和設(shè)計(jì)要求求,而且對(duì)縮縮短工期降低低成本都能起起到有利的作作用,因此制制定了自檢、互互檢、交接檢檢制度。自檢、互檢(1)制作前應(yīng)及時(shí)對(duì)對(duì)原材料、成成品、半成品品和操作質(zhì)量量進(jìn)行檢查,發(fā)發(fā)現(xiàn)材料問(wèn)題題應(yīng)立即和技技術(shù)、材料、質(zhì)質(zhì)監(jiān)部門(mén)聯(lián)系系,并暫停使使用,發(fā)現(xiàn)質(zhì)質(zhì)量問(wèn)題能及及時(shí)予以糾正正。(2)質(zhì)檢員應(yīng)協(xié)助操操作班組人員員相互檢查當(dāng)當(dāng)月班組所完完成的工程質(zhì)質(zhì)量,并將各各操作人員的的名字、級(jí)別別和質(zhì)量等級(jí)級(jí)分別寫(xiě)在所所完成的實(shí)物物上。(3)對(duì)當(dāng)天生產(chǎn)的不不符合質(zhì)量要要求的產(chǎn)品,應(yīng)應(yīng)由原操作人人員及時(shí)進(jìn)行行返修。發(fā)現(xiàn)現(xiàn)重大質(zhì)量問(wèn)問(wèn)題應(yīng)及時(shí)報(bào)報(bào)請(qǐng)上級(jí)有關(guān)關(guān)人員進(jìn)行處處理。如未及及時(shí)返修,因因而影響施工工質(zhì)量的由原原操作人員負(fù)負(fù)責(zé),同時(shí)按按有關(guān)規(guī)定給給予處罰。(4)凡未經(jīng)班組自檢檢、互檢(以以當(dāng)月班組自自檢、互檢、質(zhì)質(zhì)量檢查評(píng)定定表為準(zhǔn))施施工員和質(zhì)檢檢員有權(quán)拒絕絕驗(yàn)收,有權(quán)權(quán)拒絕在當(dāng)月月的清算任務(wù)務(wù)單上簽證質(zhì)質(zhì)量等級(jí)。交接檢(1)要工序交接時(shí)應(yīng)應(yīng)由施工負(fù)責(zé)責(zé)人召集質(zhì)檢檢員和有關(guān)人人員進(jìn)行交接接檢查,對(duì)不不符合質(zhì)量要要求的,應(yīng)根根據(jù)返修處理理的難易程度度和進(jìn)度需要要,由原施工工班組在限定定的時(shí)間內(nèi)進(jìn)進(jìn)行返修。(2)在限定時(shí)間內(nèi)不不派人返修或或未按時(shí)完成成返修而影響響下道操作,其其影響工日數(shù)數(shù)由上道工序序操作人員負(fù)負(fù)責(zé)。(3)返修工作完成后后,應(yīng)由原參參加交換檢查查的前道工序序人員進(jìn)行復(fù)復(fù)驗(yàn)認(rèn)可后,方方可進(jìn)行下道道工序操作。(4)在自檢、互檢、交交接檢的基礎(chǔ)礎(chǔ)上,由專職職質(zhì)檢員負(fù)責(zé)責(zé)抽查各個(gè)分分項(xiàng)工程的質(zhì)質(zhì)量情況,發(fā)發(fā)現(xiàn)問(wèn)題及時(shí)時(shí)通知施工負(fù)負(fù)責(zé)人或班組組,并督促期期及時(shí)進(jìn)行返返修。8工程養(yǎng)護(hù)和冬、雨雨季施工措施施8.1工程養(yǎng)養(yǎng)護(hù)措施(1)樓地面鋪貼地磚、花花崗石、大理理石等,自然然養(yǎng)護(hù)期一般般為七天,注注意勤澆水養(yǎng)養(yǎng)護(hù)。(2)養(yǎng)護(hù)期間的注意成成品保護(hù),不不許人員在地地面上走動(dòng)或或堆放材料。8.2冬雨季施施工措施(1)防雨、防潮的材料料(如礦棉板板、石膏板、木木材、水泥等等)進(jìn)場(chǎng)時(shí)間間應(yīng)盡量避開(kāi)開(kāi)下雨天,因因此收看天氣氣預(yù)報(bào),及時(shí)時(shí)掌握當(dāng)?shù)氐牡奶鞖馇闆r。(2)在施工現(xiàn)長(zhǎng)考慮足足夠的防雨、防防潮倉(cāng)庫(kù),貯貯存過(guò)程中易易受潮材料,并并準(zhǔn)備足夠數(shù)數(shù)量的抽濕設(shè)設(shè)備和干燥吸吸濕材料。(3)在施工現(xiàn)場(chǎng)和防潮潮材料倉(cāng)庫(kù)配配備一定數(shù)量量的空氣溫、濕濕度計(jì),隨時(shí)時(shí)了解空氣的的濕度,注意意通風(fēng)干燥。(4)進(jìn)入現(xiàn)場(chǎng)的木飾面面、實(shí)木線,無(wú)無(wú)論是否使用用,必須刷一一道封閉油漆漆,進(jìn)行雨季季防潮工作。(5)當(dāng)持續(xù)下雨,空氣氣濕度較大時(shí)時(shí),即溫濕度度顯示80%時(shí),在木作作施工場(chǎng),一一方面增加用用電風(fēng)扇,另另一方面放置置干燥吸濕材材料;在油漆漆施工時(shí),加加入適當(dāng)?shù)幕姿_保保工程質(zhì)量。9嚴(yán)格執(zhí)行國(guó)國(guó)家的有關(guān)施施工規(guī)范、標(biāo)標(biāo)準(zhǔn)國(guó)家的有關(guān)施工規(guī)規(guī)范、標(biāo)準(zhǔn)是是工程建設(shè)的的法律法規(guī),是是工程質(zhì)量檢檢查、驗(yàn)收的的依據(jù),在施施工中必須嚴(yán)嚴(yán)格執(zhí)行。根根據(jù)招標(biāo)工程程的實(shí)際情況況,涉及的質(zhì)質(zhì)量、安全方方面的規(guī)范、標(biāo)標(biāo)準(zhǔn)主要有::序號(hào)名稱版本號(hào)1建筑工程施工質(zhì)量量驗(yàn)收統(tǒng)一標(biāo)標(biāo)準(zhǔn)GB50300--20012工程建設(shè)標(biāo)準(zhǔn)強(qiáng)制制性條文20023建筑裝修裝飾工程程質(zhì)量驗(yàn)收規(guī)規(guī)范GB50210--20014建筑給水排水及采采暖施工質(zhì)量量驗(yàn)收規(guī)范GB50242--20025建筑電氣工程施工工質(zhì)量驗(yàn)收規(guī)規(guī)范GB50303--20026民用建筑工程室內(nèi)內(nèi)環(huán)境污染控控制規(guī)范GB50325--20017建筑地面工程施工工質(zhì)量驗(yàn)收規(guī)規(guī)范GB50209--20028砌體工程施工質(zhì)量量驗(yàn)收規(guī)范GB50203--20029玻璃幕墻工程質(zhì)量量檢驗(yàn)標(biāo)準(zhǔn)JGJ/T1399-2001110建筑施工安全檢查查標(biāo)準(zhǔn)JGJ59-99911建筑施工門(mén)式鋼管管腳手架安全全技術(shù)規(guī)范JGJ128-2200012建筑工程施工現(xiàn)場(chǎng)場(chǎng)供電用電安安全規(guī)范GB50194--9313建設(shè)工程項(xiàng)目管理理規(guī)范GB/T503226-2000114建筑施工高處作業(yè)業(yè)安全技術(shù)規(guī)規(guī)范JGJ80-91115建筑機(jī)械使用安全全技術(shù)規(guī)程JGJ33-2000116建筑施工扣件式鋼鋼管腳手架安安全技術(shù)規(guī)范范JGJ130-2200110文明施工和安全生生產(chǎn)措施10.1施工安安全保障體系系和控制事故故發(fā)生的方法法、職責(zé)為了實(shí)現(xiàn)本招標(biāo)工工程的安全目目標(biāo),我們建建立工程施工工安全保障體體系。控制事故發(fā)生的方方法、職責(zé)10.2安全職職責(zé)1)現(xiàn)場(chǎng)項(xiàng)目經(jīng)理、技技術(shù)負(fù)責(zé)人、施施工作業(yè)組組組長(zhǎng)對(duì)本職范范圍內(nèi)安全生生產(chǎn)負(fù)有領(lǐng)導(dǎo)導(dǎo)和貫徹國(guó)家家及地方安全全施工方針、政政策及落實(shí)具具體措施的責(zé)責(zé)任,將認(rèn)真真進(jìn)行遵章守守紀(jì)和安全教教育,定期或或不定期地進(jìn)進(jìn)行安全檢查查、總結(jié)、評(píng)評(píng)定。2)現(xiàn)場(chǎng)安全員嚴(yán)格格安全員崗位位責(zé)任制規(guī)定定工作,每天天親臨作業(yè)現(xiàn)現(xiàn)場(chǎng),隨時(shí)檢檢查、糾正不不安全因素,對(duì)對(duì)違章操作者者,記提示單單、清配單乃乃至罰款通知知
溫馨提示
- 1. 本站所有資源如無(wú)特殊說(shuō)明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請(qǐng)下載最新的WinRAR軟件解壓。
- 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請(qǐng)聯(lián)系上傳者。文件的所有權(quán)益歸上傳用戶所有。
- 3. 本站RAR壓縮包中若帶圖紙,網(wǎng)頁(yè)內(nèi)容里面會(huì)有圖紙預(yù)覽,若沒(méi)有圖紙預(yù)覽就沒(méi)有圖紙。
- 4. 未經(jīng)權(quán)益所有人同意不得將文件中的內(nèi)容挪作商業(yè)或盈利用途。
- 5. 人人文庫(kù)網(wǎng)僅提供信息存儲(chǔ)空間,僅對(duì)用戶上傳內(nèi)容的表現(xiàn)方式做保護(hù)處理,對(duì)用戶上傳分享的文檔內(nèi)容本身不做任何修改或編輯,并不能對(duì)任何下載內(nèi)容負(fù)責(zé)。
- 6. 下載文件中如有侵權(quán)或不適當(dāng)內(nèi)容,請(qǐng)與我們聯(lián)系,我們立即糾正。
- 7. 本站不保證下載資源的準(zhǔn)確性、安全性和完整性, 同時(shí)也不承擔(dān)用戶因使用這些下載資源對(duì)自己和他人造成任何形式的傷害或損失。
最新文檔
- 注冊(cè)會(huì)計(jì)師財(cái)務(wù)審計(jì)科技應(yīng)用試題及答案
- 房屋交易合同額外條款協(xié)議書(shū)
- 試題及答案:培養(yǎng)條件的設(shè)置
- 微生物檢驗(yàn)過(guò)程中的常見(jiàn)誤區(qū)試題及答案
- 注冊(cè)會(huì)計(jì)師考試2025年戰(zhàn)略財(cái)務(wù)管理的實(shí)施方法與挑戰(zhàn)試題及答案
- 項(xiàng)目管理法規(guī)遵循試題及答案
- 逐層深入備戰(zhàn)2025年注冊(cè)會(huì)計(jì)師考試內(nèi)容試題及答案
- 2025年證券從業(yè)資格證心理準(zhǔn)備技巧試題及答案
- 教學(xué)環(huán)境與氛圍營(yíng)造計(jì)劃
- 注冊(cè)會(huì)計(jì)師時(shí)間分配技巧試題及答案
- 慢性病管理與護(hù)理方法試題及答案
- 定向培養(yǎng)協(xié)議書(shū)模板
- 基于CRISPR-Cas9技術(shù)探索敲除RAB7A增強(qiáng)肺癌對(duì)吉西他濱敏感性的機(jī)制研究
- 社區(qū)文化活動(dòng)服務(wù)行業(yè)跨境出海戰(zhàn)略研究報(bào)告
- 汽車(chē)背戶協(xié)議合同
- 碳中和目標(biāo)下的公路建設(shè)策略-全面剖析
- 2025年山東省東營(yíng)市廣饒縣一中中考一模英語(yǔ)試題(原卷版+解析版)
- 中華傳統(tǒng)美德在幼兒園語(yǔ)言領(lǐng)域的滲透路徑探索
- T-ZZB 3624-2024 1000kV交流架空輸電線路金具
- 2025年河南應(yīng)用技術(shù)職業(yè)學(xué)院?jiǎn)握新殬I(yè)技能測(cè)試題庫(kù)匯編
- 形勢(shì)與政策(貴州財(cái)經(jīng)大學(xué))知到智慧樹(shù)章節(jié)答案
評(píng)論
0/150
提交評(píng)論