




下載本文檔
版權說明:本文檔由用戶提供并上傳,收益歸屬內容提供方,若內容存在侵權,請進行舉報或認領
文檔簡介
1、精選優質文檔-傾情為你奉上高壓電氣設備電容量一覽表交聯聚乙烯電纜每公里電容量電纜導體截面積(平方毫米)電容量(uF/Km)YJV、YJLV6/6KV、6/10KVYJV、YJLV8.7/10KV、8.7/15KVYJV、YJLV12/20KVYJV、YJLV21/35KVYJV、YJLV26/35KV1*350.2120.1730.1521*500.2370.1920.1660.1180.1141*700.2700.2170.1870.1310.1251*950.3100.2400.2060.1430.1351*1200.3270.2610.2230.1530.1431*1500.3580.2
2、840.2410.1640.1531*1850.3880.3070.2670.1800.1631*2400.4300.3390.2910.1940.1761*3000.4720.3700.3190.2110.1901*4000.5310.4180.3520.2310.2091*5000.6030.4380.3880.2540.2321*6300.6670.4700.4160.2870.256電纜導體截面積(平方毫米)電容量(uF/Km)YJV、YJLV6/6KV、6/10KVYJV、YJLV8.7/10KV、8.7/15KVYJV、YJLV12/20KVYJV、YJLV21/35KVYJV、Y
3、JLV26/35KV3*350.2120.1730.1523*500.2370.1920.1660.1180.1143*700.2700.2170.1870.1310.1251*950.3100.2400.2060.1430.1353*1200.3270.2610.2230.1530.1433*1500.3580.2840.2410.1640.1533*1850.3880.3070.2670.1800.1633*2400.4300.3390.2910.1940.1763*3000.4720.3700.3190.2110.1903*4000.5310.4180.3520.2310.2093*50
4、00.6030.4380.3880.2540.2323*6300.6670.4700.4160.2870.256電纜導體截面積(平方毫米)電容量(uF/Km)YJV、YJLV64/110KVYJV、YJLV128/220KV3*2400.1293*3000.1393*4000.1560.1181*5000.1690.1243*6300.1880.1383*8000.2140.1553*10000.2310.1723*12000.2420.1793*14000.2590.1903*16000.2730.1983*18000.2840.2073*20000.2960.2153*22000.2213
5、*25000.23260KV級全絕緣變壓器的電容(PF)試品容量(KVA)類別63020003150630080001600高壓-地270041004600590070008200低壓-地420066007900100001100015300110KV中性點分級絕緣變壓器的電容(PF) 試品容量(KVA)類別500003150020000100005600高壓-中壓、低壓、地1420011400870061504200中壓-高壓、低壓、地2480011800132009600低壓-高壓、中壓、地19300193001200094006800220KV級中性點非全級絕緣部分變壓器的電容(PF)試
6、品型號SETSL-63000SSPSL-SSPSL-類型高壓-中壓、低壓及地121001350017050中壓-高壓、低壓及地185001970023260低壓-高壓、中壓及地182002360029940試品型號SETSL-SSPSL-SSPSL-類型高壓-中壓、低壓及地322303391038020中壓-高壓、低壓及地23260低壓-高壓、中壓及地224702379022160部分發電機的電容值類別型號生產廠家額定容量(MW)額定電壓(KV)相電容(uf)汽輪發電機QFS-125-2上海電機廠12513.80.08-0.12QFSN-200-2哈爾濱電機廠20015.750.19-0.21
7、QFQS-200-2東方電機廠20015.750.1928-0.21QFQS-200-2北京重型電機廠20015.750.18-0.19QFS-300-2上海電機廠30018.00.16-0.20QFSN-300-2上海電機廠30018.00.18-0.20ATB-2美國GE公司35223.00.268(設計值)TBB-320-2(前蘇聯)32022.00.312-105*234美國西屋公司60020.00.2(工廠試驗值)50WT23E-138ABB60022.00.253(設計值)水輪發電機72.5-8510.50.69430015.751.7-2.540018.02-2.5十、附錄二:部
8、分設備試驗電壓標準:電纜30-75Hz的交流耐壓試驗電壓電纜額定電壓交接試驗電壓預防性試驗電壓U。-U倍數電壓值(KV)倍數電壓值(KV)1.8/32U。3.61.6U。33.6/62U。7.21.6U。66/62U。121.6U。106/102U。121.6U。108.7/102U。17.41.6U。1412/202U。241.6U。1921/352U。421.6U。3426/352U。521.6U。4264/1101.7U。1091.36U。87127/2201.4U。1781.15U。146變壓器的交流耐壓試驗電壓標準額定電壓KV最高工作電壓KV線端交流試驗電壓值KV中性點交流試驗電壓值
9、KV全部更換繞組部分更換繞組或交接時全部更換繞組部分更換繞組或交換時<1132.532.533.51815181566.9252125211011.5353035301517.5453845382023.0554755473540.585728572110126200170(195)9580220252.03603068572395336(200)(170)500550.06305368572680578140120發電機定子繞組交流耐壓試驗標準周期要求大修前(1)全部更換定子繞組并修好后的試驗電壓如下:容量KW或KVA額定電壓UnV試驗電壓V小于1000036以上2Un+1000但最低為150010000及以上6000以下Un6000-18000Un+300018000以上按專門協議更換繞組后(2)大修前或局部更換定子繞組并修好后試驗電壓
溫馨提示
- 1. 本站所有資源如無特殊說明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請下載最新的WinRAR軟件解壓。
- 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請聯系上傳者。文件的所有權益歸上傳用戶所有。
- 3. 本站RAR壓縮包中若帶圖紙,網頁內容里面會有圖紙預覽,若沒有圖紙預覽就沒有圖紙。
- 4. 未經權益所有人同意不得將文件中的內容挪作商業或盈利用途。
- 5. 人人文庫網僅提供信息存儲空間,僅對用戶上傳內容的表現方式做保護處理,對用戶上傳分享的文檔內容本身不做任何修改或編輯,并不能對任何下載內容負責。
- 6. 下載文件中如有侵權或不適當內容,請與我們聯系,我們立即糾正。
- 7. 本站不保證下載資源的準確性、安全性和完整性, 同時也不承擔用戶因使用這些下載資源對自己和他人造成任何形式的傷害或損失。
最新文檔
- 2019年全國生物聯賽試題及答案
- 戀愛合同協議文字模板
- 員工還款合同協議
- 商品房購銷合同解除協議
- 快遞共配公司合同協議
- 商品試用買賣合同協議
- 比賽免責協議書范本
- 品牌運營權授權合同協議
- 民俗建筑設計合同協議
- 民宿合作協議合同協議
- 2024年同等學力申碩-同等學力(政治學)歷年高頻考點試卷專家薈萃含答案
- 感染科業務培訓計劃
- 2021年中國中車公司組織架構和部門職能
- 鐵路工程項目工程量清單
- 開放大學辦學組織體系建設的困境與突破路徑
- 立式機組軸線調整及瓦間隙計算
- VDA6-3的要求與說明
- 樁水平承載力計算
- 重癥肺炎患者護理查房PPT
- GB 43067-2023煤礦用儀器儀表安全技術要求
- 大課間跑操評分表
評論
0/150
提交評論