




版權說明:本文檔由用戶提供并上傳,收益歸屬內容提供方,若內容存在侵權,請進行舉報或認領
文檔簡介
100MW山地光伏(漁光互補)項目質量驗收范圍劃分表編制單位:光伏發電監理項目部二〇二四年十二月
目錄一、編制說明 -2-工程編號工程名稱驗收單位本部分編號單位工程子單位工程分部工程子分部工程分項工程檢驗批施工單位勘測單位設計單位總承包單位監理單位建設單位1土建工程√√√√√DL/T5210.1表3.0.12-4~-3.0.12.7、3.0.141光伏區土建工程√√√√√DL/T5210.1表3.0.12-4~-3.0.12.7、3.0.141光伏支架基礎√√√√DL/T5210.1表3.0.12-31#1陣列(地塊)光伏支架基礎√√√√DL/T5210.1表3.0.12-31定位及高程控制√√√DL/T5210.1表3.0.12-21定位及高程控制√√√DL/T5210.1表5.2.12混凝土預制樁施工(錘擊)√√√DL/T5210.1表3.0.12-21混凝土預制樁施工(錘擊)√√√DL/T5210.1表5.7.42#2方陣光伏支架基礎√√√√DL/T5210.1表3.0.12-31定位及高程控制√√√DL/T5210.1表3.0.12-21定位及高程控制√√√DL/T5210.1表5.2.12混凝土預制樁施工(錘擊)√√√DL/T5210.1表3.0.12-21混凝土預制樁施工(錘擊)√√√DL/T5210.1表5.7.43#3方陣光伏支架基礎√√√√DL/T5210.1表3.0.12-31定位及高程控制√√√DL/T5210.1表3.0.12-21定位及高程控制√√√DL/T5210.1表5.2.12混凝土預制樁施工(錘擊)√√√DL/T5210.1表3.0.12-21混凝土預制樁施工(錘擊)√√√DL/T5210.1表5.7.44#4方陣光伏支架基礎√√√√DL/T5210.1表3.0.12-31定位及高程控制√√√DL/T5210.1表3.0.12-21定位及高程控制√√√DL/T5210.1表5.2.12混凝土預制樁施工(錘擊)√√√DL/T5210.1表3.0.12-21混凝土預制樁施工(錘擊)√√√DL/T5210.1表5.7.45#5方陣光伏支架基礎√√√√DL/T5210.1表3.0.12-31定位及高程控制√√√DL/T5210.1表3.0.12-21定位及高程控制√√√DL/T5210.1表5.2.12混凝土預制樁施工(錘擊)√√√DL/T5210.1表3.0.12-21混凝土預制樁施工(錘擊)√√√DL/T5210.1表5.7.42箱式變壓器基礎√√√√√DL/T5210.1表3.0.12-31#1方陣變壓器基礎√√√√√DL/T5210.1表3.0.12-31定位及高程控制√√√DL/T5210.1表3.0.12-21定位及高程控制√√√DL/T5210.1表5.2.12挖方√√√DL/T5210.1表3.0.12-21土(石)方開挖√√√DL/T5210.1表5.3.1、表5.3.23填方√√√DL/T5210.1表3.0.12-21土方回填√√√DL/T5210.1表5.3.31混凝土墊層√√√DL/T5210.1表5.17.2-65模板√√√DL/T5210.1表3.0.12-21模板安裝√√√DL/T5210.1表5.12.16鋼筋√√√DL/T5210.1表3.0.12-21鋼筋加工√√√DL/T5210.1表5.12.62鋼筋安裝√√√DL/T5210.1表5.12.87混凝土√√√DL/T5210.1表3.0.12-21混凝土原材料及拌合物√√√DL/T5210.1表5.12.92混凝土施工√√√DL/T5210.1表5.12.103混凝土外觀及尺寸偏差√√√DL/T5210.1表5.12.118排油管安裝√√√DL/T5210.1表3.0.12-21排油管安裝√√√DL/T5210.1表5.31.162排油管防腐√√√DL/T5210.1表5.30.1~5.30.42#2方陣變壓器基礎√√√√DL/T5210.1表3.0.12-31定位及高程控制√√√DL/T5210.1表3.0.12-21定位及高程控制√√√DL/T5210.1表5.2.12挖方√√√DL/T5210.1表3.0.12-21土(石)方開挖√√√DL/T5210.1表5.3.1、表5.3.23填方√√√DL/T5210.1表3.0.12-24墊層√√√DL/T5210.1表3.0.12-21混凝土墊層√√√DL/T5210.1表5.17.2-65模板√√√DL/T5210.1表3.0.12-21模板安裝√√√DL/T5210.1表5.12.16鋼筋√√√DL/T5210.1表3.0.12-21鋼筋加工√√√DL/T5210.1表5.12.62鋼筋安裝√√√DL/T5210.1表5.12.87混凝土√√√DL/T5210.1表3.0.12-21混凝土原材料及拌合物√√√DL/T5210.1表5.12.92混凝土施工√√√DL/T5210.1表5.12.103混凝土外觀及尺寸偏差√√√DL/T5210.1表5.12.118排油管安裝√√√DL/T5210.1表3.0.12-21排油管安裝√√√DL/T5210.1表5.31.162排油管防腐√√√DL/T5210.1表5.30.1~5.30.43#3方陣變壓器基礎√√√√DL/T5210.1表3.0.12-31定位及高程控制√√√DL/T5210.1表3.0.12-21定位及高程控制√√√DL/T5210.1表5.2.12挖方√√√DL/T5210.1表3.0.12-21土(石)方開挖√√√DL/T5210.1表5.3.1、表5.3.23填方√√√DL/T5210.1表3.0.12-21土方回填√√√DL/T5210.1表5.3.34墊層√√√DL/T5210.1表3.0.12-21混凝土墊層√√√DL/T5210.1表5.17.2-65模板√√√DL/T5210.1表3.0.12-21模板安裝√√√DL/T5210.1表5.12.16鋼筋√√√DL/T5210.1表3.0.12-21鋼筋加工√√√DL/T5210.1表5.12.62鋼筋安裝√√√DL/T5210.1表5.12.87混凝土√√√DL/T5210.1表3.0.12-21混凝土原材料及拌合物√√√DL/T5210.1表5.12.92混凝土施工√√√DL/T5210.1表5.12.103混凝土外觀及尺寸偏差√√√DL/T5210.1表5.12.118排油管安裝√√√DL/T5210.1表3.0.12-21排油管安裝√√√DL/T5210.1表5.31.162排油管防腐√√√DL/T5210.1表5.30.1~5.30.44#4方陣變壓器基礎√√√√DL/T5210.1表3.0.12-31定位及高程控制√√√DL/T5210.1表3.0.12-21定位及高程控制√√√DL/T5210.1表5.2.12挖方√√√DL/T5210.1表3.0.12-21土(石)方開挖√√√DL/T5210.1表5.3.1、表5.3.23填方√√√DL/T5210.1表3.0.12-21土方回填√√√DL/T5210.1表5.3.34墊層√√√DL/T5210.1表3.0.12-21混凝土墊層√√√DL/T5210.1表5.17.2-65模板√√√DL/T5210.1表3.0.12-21模板安裝√√√DL/T5210.1表5.12.16鋼筋√√√DL/T5210.1表3.0.12-21鋼筋加工√√√DL/T5210.1表5.12.62鋼筋安裝√√√DL/T5210.1表5.12.87混凝土√√√DL/T5210.1表3.0.12-21混凝土原材料及拌合物√√√DL/T5210.1表5.12.92混凝土施工√√√DL/T5210.1表5.12.103混凝土外觀及尺寸偏差√√√DL/T5210.1表5.12.118排油管安裝√√√DL/T5210.1表3.0.12-21排油管安裝√√√DL/T5210.1表5.31.162排油管防腐√√√DL/T5210.1表5.30.1~5.30.45#5方陣變壓器基礎√√√√DL/T5210.1表3.0.12-31定位及高程控制√√√DL/T5210.1表3.0.12-21定位及高程控制√√√DL/T5210.1表5.2.12挖方√√√DL/T5210.1表3.0.12-21土(石)方開挖√√√DL/T5210.1表5.3.1、表5.3.23填方√√√DL/T5210.1表3.0.12-21土方回填√√√DL/T5210.1表5.3.34墊層√√√DL/T5210.1表3.0.12-21混凝土墊層√√√DL/T5210.1表5.17.2-65模板√√√DL/T5210.1表3.0.12-21模板安裝√√√DL/T5210.1表5.12.16鋼筋√√√DL/T5210.1表3.0.12-21鋼筋加工√√√DL/T5210.1表5.12.62鋼筋安裝√√√DL/T5210.1表5.12.87混凝土√√√DL/T5210.1表3.0.12-21混凝土原材料及拌合物√√√DL/T5210.1表5.12.92混凝土施工√√√DL/T5210.1表5.12.103混凝土外觀及尺寸偏差√√√DL/T5210.1表5.12.118排油管安裝√√√DL/T5210.1表3.0.12-21排油管安裝√√√DL/T5210.1表5.31.162排油管防腐√√√DL/T5210.1表5.30.1~5.30.42場區及地下設施√√√√√DL/T5210.1表3.0.12-4~-3.0.12.7、3.0.141場區平整√√√√√DL/T5210.1表3.0.12-31地基工程√√√√√DL/T5210.1表3.0.12-31定位及高程控制√√√DL/T5210.1表3.0.12-21定位及高程控制√√√DL/T5210.1表5.2.12挖方√√√DL/T5210.1表3.0.12-21土(石)方開挖√√√DL/T5210.1表5.3.1、表5.3.23填方√√√DL/T5210.1表3.0.12-21土方回填√√√DL/T5210.1表5.3.32道路工程√√√√DL/T5210.1表3.0.12-31場區道路√√√√DL/T5210.1表3.0.12-31路基工程√√√DL/T5210.1表3.0.12-21土方路基(3km一個檢驗批)√√√JTGF80/1表4.2.22填石路基√√√JTGF80/1表4.3.22基層√√√DL/T5210.1表3.0.12-21填隙碎石(礦渣)基層√√√JTGF80/1表7.9.23面層√√√DL/T5210.1表3.0.12-21級配碎(礫)石面層√√√JTGF80/1表7.8.23光伏場區圍欄√√√√DL/T5210.1表3.0.12-31#1方陣光伏區圍欄√√√√DL/T5210.1表3.0.12-31基礎混凝土√√√DL/T5210.1表3.0.12-21混凝土材料及拌合物√√√DL/T5210.1表5.12.92混凝土施工√√√DL/T5210.1表5.12.103混凝土結構外觀尺寸偏差√√√DL/T5210.1表5.12.112圍欄安裝√√√DL/T5210.1表3.0.12-21圍欄安裝√√√DL/T5210.1表5.13.192#2方陣光伏區圍欄√√√√DL/T5210.1表3.0.12-31基礎混凝土√√√DL/T5210.1表3.0.12-21混凝土材料及拌合物√√√DL/T5210.1表5.12.92混凝土施工√√√DL/T5210.1表5.12.103混凝土結構外觀尺寸偏差√√√DL/T5210.1表5.12.112圍欄安裝√√√DL/T5210.1表3.0.12-21圍欄安裝√√√DL/T5210.1表5.13.193#3方陣光伏區圍欄√√√√DL/T5210.1表3.0.12-31基礎混凝土√√√DL/T5210.1表3.0.12-21混凝土材料及拌合物√√√DL/T5210.1表5.12.92混凝土施工√√√DL/T5210.1表5.12.103混凝土結構外觀尺寸偏差√√√DL/T5210.1表5.12.112圍欄安裝√√√DL/T5210.1表3.0.12-21圍欄安裝√√√DL/T5210.1表5.13.193#4方陣光伏區圍欄√√√√DL/T5210.1表3.0.12-31基礎混凝土√√√DL/T5210.1表3.0.12-21混凝土材料及拌合物√√√DL/T5210.1表5.12.92混凝土施工√√√DL/T5210.1表5.12.103混凝土結構外觀尺寸偏差√√√DL/T5210.1表5.12.112圍欄安裝√√√DL/T5210.1表3.0.12-21圍欄安裝√√√DL/T5210.1表5.13.193#5方陣光伏區圍欄√√√√DL/T5210.1表3.0.12-31基礎混凝土√√√DL/T5210.1表3.0.12-21混凝土材料及拌合物√√√DL/T5210.1表5.12.92混凝土施工√√√DL/T5210.1表5.12.103混凝土結構外觀尺寸偏差√√√DL/T5210.1表5.12.112圍欄安裝√√√DL/T5210.1表3.0.12-21圍欄安裝√√√DL/T5210.1表5.13.193混凝土結構外觀尺寸偏差√√√DL/T5210.1表5.12.1103升壓站土建工程√√√√√DL/T5210.1表3.0.12-4~-3.0.12.701升壓站站區平整√√√√√DL/T5210.1表3.0.12-4~-3.0.12.701站區平整√√√√√DL/T5210.1表3.0.12-301定位及高程控制√√√DL/T5210.1表3.0.12-201定位及高程控制√√√DL/T5210.1表5.2.102挖方√√√DL/T5210.1表3.0.12-201土方開挖√√√DL/T5210.1表5.3.103填方√√√DL/T5210.1表3.0.12-201土方回填√√√DL/T5210.1表5.3.202綜合樓√√√√√√DL/T5210.13.0.12-4~-3.0.12.7O1地基與基礎工程√√√√√√DL/T5210.1表3.0.12-3O1定位及高程控制√√√DL/T5210.1表3.0.12-2O1定位及高程控制√√√DL/T5210.1表5.2.1O2挖方√√√DL/T5210.1表3.0.12-2O1土(石)方開挖√√√DL/T5210.1表5.3.1~2O3填方√√√DL/T5210.1表3.0.12-2O1土方回填√√√DL/T5210.1表5.3.304土石方堆放√√√√√DL/T5210.1表3.0.12-201土石方堆放√√√DL/T5210.1表5.3.4O5墊層√√√DL/T5210.1表3.0.12-2O1墊層√√√DL/T5210.1表5.17.2-1~6O6基礎模板√√√DL/T5210.1表3.0.12-2O1模板安裝√√√DL/T5210.1表5.12.1O7基礎鋼筋√√√DL/T5210.1表3.0.12-2O1鋼筋加工√√√DL/T5210.1表5.12.6O2鋼筋安裝√√√DL/T5210.1表5.12.8O8基礎混凝土√√√DL/T5210.1表3.0.12-2O1混凝土原材料及拌合物√√√DL/T5210.1表5.12.9O2混凝土施工√√√DL/T5210.1表5.12.10O3混凝土結構外觀及尺寸偏差√√√DL/T5210.1表5.12.1102主體結構√√√√√DL/T5210.1表3.0.12-3O1模板√√√DL/T5210.1表3.0.12-2O1現澆混凝土結構模板安裝√√√DL/T5210.1表5.12.1O2鋼筋√√√DL/T5210.1表3.0.12-2O1鋼筋加工√√√DL/T5210.1表5.12.6O2鋼筋安裝√√√DL/T5210.1表5.12.8O3混凝土√√√DL/T5210.1表3.0.12-2O1混凝土原材料及拌合物√√√DL/T5210.1表5.12.9O2混凝土施工√√√DL/T5210.1表5.12.10O3混凝土結構外觀及尺寸偏差√√√DL/T5210.1表5.12.11O4磚砌體工程√√√DL/T5210.1表3.0.12-2O1填充墻砌體√√√DL/T5210.1表5.11.5O3建筑裝飾裝修√√√√√DL/T5210.1表3.0.12-301樓面與地面√√√DL/T5210.1表3.0.12-2O1基土質量√√√DL/T5210.1表5.17.1O2墊層√√√DL/T5210.1表5.17.2-2~6O3中間層處理√√√DL/T5210.1表5.17.3-1~4O4防水層√√√DL/T5210.1表5.17.1O5面層√√√DL/T5210.1表5.17.2-1~24O2抹灰√√√DL/T5210.1表3.0.12-2O1一般抹灰√√√DL/T5210.1表5.18.1O2保溫層薄抹灰√√√DL/T5210.1表5.18.2O3門窗√√√DL/T5210.1表3.0.12-2O1木門窗安裝√√√DL/T5210.1表5.20.1O2金屬門窗安裝√√√DL/T5210.1表5.20.2O3特種門安裝√√√DL/T5210.1表5.20.4-1~3O4門窗玻璃安裝√√√DL/T5210.1表5.20.6O4吊頂√√√DL/T5210.1表3.0.12-2O1板塊面層吊頂√√√DL/T5210.1表5.15.21-2O5飾面板(磚)√√√DL/T5210.1表3.0.12-2O1內墻面磚粘貼√√√DL/T5210.1表5.24.1O6涂飾√√√DL/T5210.1表3.0.12-2O1水性涂料涂飾√√√DL/T5210.1表5.26.1O4建筑屋面√√√√√DL/T5210.1表3.0.12-3O1基層與保護√√√DL/T5210.1表3.0.12-2O1屋面找平層√√√DL/T5210.1表5.29.1O2保溫與隔熱√√√DL/T5210.1表3.0.12-2O1保溫層√√√DL/T5210.1表5.29.5O3防水與密封√√√DL/T5210.1表3.0.12-2O3屋面卷材防水層√√√DL/T5210.1表5.29.9O5建筑給、排水及采暖√√√√√DL/T5210.1表3.0.12-3O1室內給水系統√√√√√DL/T5210.1表3.0.12-201室內給水管道及配件安裝√√√DL/T5210.1表5.31.1O2室內排水系統√√√DL/T5210.1表3.0.12-201室內排水管道及配件安裝√√√DL/T5210.1表5.31.3O3衛生器具安裝√√√DL/T5210.1表3.0.12-201衛生器具安裝√√√DL/T5210.1表5.31.7O2衛生器具給水配件安裝√√√DL/T5210.1表5.31.8O2衛生器具排水管道安裝√√√DL/T5210.1表5.31.9O6通風與空調√√√DL/T5210.1表3.0.12-3O1通風與空調設備安裝√√√DL/T5210.1表3.0.12-2O1通風與空調設備安裝√√√DL/T5210.1表5.32.12O2工程系統調試√√√DL/T5210.1表3.0.12-2O1工程系統調試√√√DL/T5210.1表5.32.1907建筑電氣√√√√DL/T5210.1表3.0.12-301室內電氣照明安裝工程√√√DL/T5210.1表3.0.12-201成套配電柜、控制柜(屏、臺)和動力、照明配電箱(盤)安裝√√√DL/T5210.1表5.33.102電線導管、電纜導管和線槽敷設安裝√√√DL/T5210.1表5.33.203電線、電纜穿管和線槽敷設√√√DL/T5210.1表5.33.304電纜頭制作、接線和線路絕緣測試√√√DL/T5210.1表5.33.605普通燈具安裝√√√DL/T5210.1表5.33.706專用燈具安裝√√√DL/T5210.1表5.33.807開關、插座、風扇安裝√√√DL/T5210.1表5.33.1008建筑物照明通電試運行√√√DL/T5210.1表5.33.1109接地裝置安裝√√√DL/T5210.1表5.33.1202防雷接地裝置安裝√√√DL/T5210.1表3.0.12-201接地裝置安裝√√√DL/T5210.1表5.33.1202避雷引下線安裝及接閃器安裝√√√DL/T5210.1表5.33.1303建筑物等電位連接及浪涌保護器安裝√√√DL/T5210.1表5.33.1508智能建筑工程√√√DL/T5210.1表3.0.12-301建筑設備監控系統√√√DL/T5210.1表3.0.12-301線纜敷設√√√DL/T5210.1表5.34.102設備及軟件安裝√√√DL/T5210.1表5.34.603系統調試運行√√√DL/T5210.1表5.34.702火災自動報警及消防聯動系統工程√√√DL/T5210.1表3.0.12-301線纜敷設及附件安裝√√√DL/T5210.1表5.34.802設備及附件安裝√√√DL/T5210.1表5.34.903系統調試運行√√√DL/T5210.1表5.34.1003安全技術防范系統√√√DL/T5210.1表3.0.12-301線纜敷設√√√DL/T5210.1表5.34.102設備及軟件安裝√√√DL/T5210.1表5.34.1103系統調試運行√√√DL/T5210.1表5.34.1204防雷與接地√√√DL/T5210.1表3.0.12-301接地裝置安裝√√√DL/T5210.1表5.34.1302等電位連接及浪涌保護器安裝√√√DL/T5210.1表5.34.1403接地系統測試工程√√√DL/T5210.1表5.34.1509建筑節能工程√√√DL/T5210.1表3.0.12-301圍護系統節能√√√DL/T5210.1表3.0.12-201墻體節能工程√√√DL/T5210.1表5.35.102門窗節能工程 √√√DL/T5210.1表5.35.303屋面節能工程√√√DL/T5210.1表5.35.402電氣動力節能√√√DL/T5210.1表3.0.12-201配電與照明節能工程√√√DL/T5210.1表5.35.90335kV配電室√√√√√DL/T5210.1表3.0.12-301地基與基礎工程√√√√√DL/T5210.1表3.0.12-301定位及高程控制√√√DL/T5210.1表3.0.12-201定位及高程控制√√√DL/T5210.1表5.2.102挖方√√√DL/T5210.1表3.0.12-201土(石)方開挖√√√DL/T5210.1表5.3.1~5.3.203填方√√√DL/T5210.1表3.0.12-201土方回填√√√DL/T5210.1表5.3.304土石方堆放√√√√√DL/T5210.1表3.0.12-201土石方堆放√√√DL/T5210.1表5.3.405墊層√√√DL/T5210.1表3.0.12-201墊層√√√DL/T5210.1表5.17.2-1~5.17.2-606基礎模板√√√DL/T5210.1表3.0.12-201模板安裝√√√DL/T5210.1表5.12.107基礎鋼筋√√√DL/T5210.1表3.0.12-201鋼筋加工√√√DL/T5210.1表5.12.602鋼筋安裝√√√DL/T5210.1表5.12.808基礎混凝土√√√DL/T5210.1表3.0.12-201混凝土原材料及拌合物√√√DL/T5210.1表5.12.902混凝土施工√√√DL/T5210.1表5.12.1003混凝土結構外觀尺寸偏差√√√DL/T5210.1表5.12.1104主變區域√√√√√√DL/T5210.1表3.0.12-301地基工程√√√√√DL/T5210.1表3.0.12-301定位及高程控制√√√DL/T5210.1表3.0.12-201定位及高程控制√√√DL/T5210.1表5.2.102挖方√√√DL/T5210.1表3.0.12-201土(石)方開挖√√√DL/T5210.1表5.3.1~5.3.203填方√√√DL/T5210.1表3.0.12-201土方回填√√√DL/T5210.1表5.3.302主變壓器基礎√√√√DL/T5210.1表3.0.12-301墊層√√√DL/T5210.1表3.0.12-201墊層√√√DL/T5210.1表5.17.202模板√√√DL/T5210.1表3.0.12-201模板安裝√√√DL/T5210.1表5.12.103鋼筋√√√DL/T5210.1表3.0.12-201鋼筋加工√√√DL/T5210.1表5.12.602鋼筋安裝√√√DL/T5210.1表5.12.804混凝土√√√DL/T5210.1表3.0.12-201混凝土原材料及拌合物√√√DL/T5210.1表5.12.902混凝土施工√√√DL/T5210.1表5.12.1003混凝土外觀及尺寸偏差√√√DL/T5210.1表5.12.1103廠用變壓器基礎√√√√DL/T5210.1表3.0.12-301墊層√√√DL/T5210.1表3.0.12-201墊層√√√DL/T5210.1表5.17.202模板√√√DL/T5210.1表3.0.12-201模板安裝√√√DL/T5210.1表5.12.103鋼筋√√√DL/T5210.1表3.0.12-201鋼筋加工√√√DL/T5210.1表5.12.602鋼筋安裝√√√DL/T5210.1表5.12.804混凝土√√√DL/T5210.1表3.0.12-201混凝土原材料及拌合物√√√DL/T5210.1表5.12.902混凝土施工√√√DL/T5210.1表5.12.1003混凝土外觀及尺寸偏差√√√DL/T5210.1表5.12.1104主變架構√√√√DL/T5210.1表3.0.12-301架構基礎墊層√√√DL/T5210.1表3.0.12-201墊層√√√DL/T5210.1表5.17.202基礎模板√√√DL/T5210.1表3.0.12-201模板安裝√√√DL/T5210.1表5.12.103基礎鋼筋√√√DL/T5210.1表3.0.12-201鋼筋加工√√√DL/T5210.1表5.12.602鋼筋安裝√√√DL/T5210.1表5.12.804架構基礎混凝土√√√DL/T5210.1表3.0.12-201混凝土原材料及拌合物√√√DL/T5210.1表5.12.902混凝土施工√√√DL/T5210.1表5.12.1003混凝土外觀及尺寸偏差√√√DL/T5210.1表5.12.1105架構安裝√√√DL/T5210.1表3.0.12-201鋼架構安裝√√√DL/T5210.1表13.1905事故油坑、油池、排油管√√√√DL/T5210.1表3.0.12-301墊層√√√DL/T5210.1表3.0.12-201墊層√√√DL/T5210.1表5.17.202油池、油坑模板√√√DL/T5210.1表3.0.12-201模板安裝√√√DL/T5210.1表5.12.103油池、油坑鋼筋√√√DL/T5210.1表3.0.12-201鋼筋加工√√√DL/T5210.1表5.12.602鋼筋安裝√√√DL/T5210.1表5.12.804油池、油坑混凝土√√√DL/T5210.1表3.0.12-201混凝土原材料及拌合物√√√DL/T5210.1表5.12.902混凝土施工√√√DL/T5210.1表5.12.1003混凝土外觀及尺寸偏差√√√DL/T5210.1表5.12.1105排油管安裝√√√DL/T5210.1表3.0.12-201排油管安裝√√√DL/T5210.1表5.31.1605110kV屋外配電裝置√√√√√√DL/T5210.1表3.0.12-301地基工程√√√√√DL/T5210.1表3.0.12-301定位及高程控制√√√DL/T5210.1表3.0.12-201定位及高程控制√√√DL/T5210.1表5.2.102挖方√√√DL/T5210.1表3.0.12-201土(石)方開挖√√√DL/T5210.1表5.3.1~5.3.203填方√√√DL/T5210.1表3.0.12-201土方回填√√√DL/T5210.1表5.3.302SVG基礎√√√√DL/T5210.1表3.0.12-301墊層√√√DL/T5210.1表3.0.12-201墊層√√√DL/T5210.1表5.17.202模板√√√DL/T5210.1表3.0.12-201模板安裝√√√DL/T5210.1表5.12.103鋼筋√√√DL/T5210.1表3.0.12-201鋼筋加工√√√DL/T5210.1表5.12.602鋼筋安裝√√√DL/T5210.1表5.12.804混凝土√√√DL/T5210.1表3.0.12-201混凝土原材料及拌合物√√√DL/T5210.1表5.12.902混凝土施工√√√DL/T5210.1表5.12.1003混凝土外觀及尺寸偏差√√√DL/T5210.1表5.12.1103設備基礎及支架√√√√DL/T5210.1表3.0.12-301基礎墊層√√√DL/T5210.1表3.0.12-201墊層√√√DL/T5210.1表5.17.202基礎模板√√√DL/T5210.1表3.0.12-201模板安裝√√√DL/T5210.1表5.12.103基礎混凝土√√√DL/T5210.1表3.0.12-201混凝土原材料及拌合物√√√DL/T5210.1表5.12.902混凝土施工√√√DL/T5210.1表5.12.1003混凝土外觀及尺寸偏差√√√DL/T5210.1表5.12.1104支架安裝√√√DL/T5210.1表3.0.12-201支架安裝√√√DL/T5210.1表11.3.1004電纜溝√√√√DL/T5210.1表3.0.12-301磚砌溝道砌體工程√√√DL/T5210.1表3.0.12-201磚砌溝道砌體工程√√√DL/T5210.1表11.4.102磚砌溝道抹灰√√√DL/T5210.1表3.0.12-201磚砌溝道抹灰√√√DL/T5210.1表5.18.103溝道墊層√√√DL/T5210.1表3.0.12-201墊層√√√DL/T5210.1表5.17.204溝道模板√√√DL/T5210.1表3.0.12-201模板安裝√√√DL/T5210.1表5.12.105溝道鋼筋√√√DL/T5210.1表3.0.12-201鋼筋加工√√√DL/T5210.1表5.12.602鋼筋安裝√√√DL/T5210.1表5.12.806溝道混凝土√√√DL/T5210.1表3.0.12-201混凝土原材料及拌合物√√√DL/T5210.1表5.12.902混凝土施工√√√DL/T5210.1表5.12.1003混凝土外觀及尺寸偏差√√√DL/T5210.1表5.12.1107蓋板安裝√√√√DL/T5210.1表3.0.12-201蓋板安裝√√√√DL/T5210.1表11.4.1205110kV戶外配電裝置區域工程√√√√DL/T5210.1表3.0.12-301圍欄安裝√√√DL/T5210.1表3.0.12-201圍欄安裝√√√DL/T5210.1表5.13.1906綜合水泵房√√√√√DL/T5210.1表3.0.12-301地基與基礎工程√√√√√DL/T5210.1表3.0.12-301定位及高程控制√√√DL/T5210.1表3.0.12-201定位及高程控制√√√DL/T5210.1表5.2.102挖方√√√DL/T5210.1表3.0.12-201土(石)方開挖√√√DL/T5210.1表5.3.1~5.3.203填方√√√DL/T5210.1表3.0.12-201土方回填√√√DL/T5210.1表5.3.304土石方堆放√√√√√DL/T5210.1表3.0.12-201土石方堆放√√√DL/T5210.1表5.3.405墊層√√√DL/T5210.1表3.0.12-201墊層√√√DL/T5210.1表5.17.2-1~5.17.2-606基礎模板√√√DL/T5210.1表3.0.12-201模板安裝√√√DL/T5210.1表5.12.107基礎鋼筋√√√DL/T5210.1表3.0.12-201鋼筋加工√√√DL/T5210.1表5.12.602鋼筋安裝√√√DL/T5210.1表5.12.808基礎混凝土√√√DL/T5210.1表3.0.12-201混凝土原材料及拌合物√√√DL/T5210.1表5.12.902混凝土施工√√√DL/T5210.1表5.12.1003混凝土結構外觀尺寸偏差√√√DL/T5210.1表5.12.1107站區附屬工程√√√√√√DL/T5210.1表3.0.12-4~3.0.12-1001站區道路、地坪√√√√√DL/T5210.1表3.0.12-301定位及高程控制√√√DL/T5210.1表3.0.12-201定位及高程控制√√√DL/T5210.1表5.2.102挖方√√√DL/T5210.1表3.0.12-201土(石)方開挖√√√DL/T5210.15.3.1~5.3.203土石方堆放√√√DL/T5210.1表3.0.12-201土石方堆放√√√DL/T5210.1表5.3.404土方路基√√√DL/T5210.1表3.0.12-201土方路基√√√DL/T5210.1表5.37.105基層√√√DL/T5210.1表3.0.12-201級配碎石及級配碎礫石基層√√√DL/T5210.1表5.37.502水泥穩定類基層√√√DL/T5210.1表5.37.806路面√√√DL/T5210.1表3.0.12-201路面混凝土原材料及拌合物√√√DL/T5210.1表5.12.902路面混凝土施工√√√DL/T5210.1表5.12.1003水泥混凝土面層√√√DL/T5210.1表5.37.904路緣石√√√DL/T5210.1表5.37.1602站區圍墻及大門√√√√DL/T5210.1表3.0.12-301定位及高程控制√√√DL/T5210.1表3.0.12-201定位及高程控制√√√DL/T5210.1表5.2.102挖方√√√DL/T5210.1表3.0.12-201土(石)方開挖√√√DL/T5210.1表5.3.1~5.3.203填方√√√DL/T5210.1表3.0.12-201土方回填√√√DL/T5210.1表5.3.304基礎墊層√√√DL/T5210.1表3.0.12-201墊層√√√DL/T5210.1表5.17.2-1~5.17.2-605基礎砌體√√√DL/T5210.1表3.0.12-201基礎砌筑√√√DL/T5210.1表5.11.1、5.11.306主體砌體√√√DL/T5210.1表3.0.12-201主體砌筑√√√DL/T5210.1表5.11.1、5.11.307裝飾裝修工程√√√DL/T5210.1表3.0.12-201一般抹灰√√√DL/T5210.1表5.18.102外墻面磚粘貼√√√DL/T5210.1表5.24.208圍欄及大門安裝√√√√DL/T5210.1表3.0.12-201大門安裝√√√DL/T5210.1表5.20.4-103站區給排水√√√DL/T5210.1表3.0.12-301室外給水管網√√√DL/T5210.1表3.0.12-201室外給水管道安裝√√√DL/T5210.1表5.31.1402室外排水管網√√√DL/T5210.1表3.0.12-301室外排水管道安裝√√√DL/T5210.1表5.31.1602室外排水管溝及井池√√√DL/T5210.1表5.31.1703常規水消防工程√√√DL/T5210.1表3.0.12-301室外給水管道安裝√√√DL/T5210.1表5.31.1402消防水泵接合器及室外消火栓安裝√√√DL/T5210.1表5.31.2504排水溝√√√DL/T5210.1表3.0.12-201磚砌溝道√√√DL/T5210.1表11.4.104站區照明√√√√DL/T5210.1表3.0.12-301成套配電柜、控制柜(屏、臺)和動力、照明配電箱(盤)安裝√√√DL/T5210.1表3.0.12-201成套配電柜、控制柜(屏、臺)和動力、照明配電箱(盤)安裝√√√DL/T5210.1表5.33.102電線、電纜導管和線槽敷設安裝√√√DL/T5210.1表3.0.12-201電線、電纜導管和線槽敷設安裝√√√DL/T5210.1表5.33.303電線、電纜穿管和線槽敷線√√√DL/T5210.1表3.0.12-201電線、電纜穿管和線槽敷線√√√DL/T5210.1表5.33.404電纜頭制作、接線和線路絕緣測試√√√DL/T5210.1表3.0.12-201電纜頭制作、接線和線路絕緣測試√√√DL/T5210.1表5.33.605建筑物景觀照明燈、航空障礙標志燈和庭院燈安裝√√√DL/T5210.1表3.0.12-201建筑物景觀照明燈、航空障礙標志燈和庭院燈安裝√√√DL/T5210.1表5.33.906照明通電試運行√√√DL/T5210.1表3.0.12-201照明通電試運行√√√DL/T5210.1表5.33.1107接地裝置安裝√√√DL/T5210.1表3.0.12-201接地裝置安裝√√√DL/T5210.1表5.33.1205水土保持工程√√√√DL/T5210.1表3.0.12-301土地整治工程√√√DL/T5210.1表3.0.12-201土地整治工程√√√DL/T5210.1表5.38.202站內綠化√√√DL/T5210.1表3.0.12-301草坪、花壇、地被栽植工程√√√DL/T5210.1表5.39.2010308附屬用房√√√√√√O1地基與基礎工程√√√√√√DL/T5210.1表3.0.12-3O1定位及高程控制√√√DL/T5210.1表3.0.12-2O1定位及高程控制√√√DL/T5210.1表5.2.1O2挖方√√√DL/T5210.1表3.0.12-2O1土(石)方開挖√√√DL/T5210.1表5.3.1~2O3填方√√√DL/T5210.1表3.0.12-2O1土方回填√√√DL/T5210.1表5.3.304土石方堆放√√√√√DL/T5210.1表3.0.12-201土石方堆放√√√DL/T5210.1表5.3.4O5墊層√√√DL/T5210.1表3.0.12-2O1墊層√√√DL/T5210.1表5.17.2-1~6O6基礎模板√√√DL/T5210.1表3.0.12-2O1模板安裝√√√DL/T5210.1表5.12.1O7基礎鋼筋√√√DL/T5210.1表3.0.12-2O1鋼筋加工√√√DL/T5210.1表5.12.6O2鋼筋安裝√√√DL/T5210.1表5.12.8O8基礎混凝土√√√DL/T5210.1表3.0.12-2O1混凝土原材料及拌合物√√√DL/T5210.1表5.12.9O2混凝土施工√√√DL/T5210.1表5.12.10O3混凝土結構外觀及尺寸偏差√√√DL/T5210.1表5.12.1101030802主體結構√√√√√DL/T5210.1表3.0.12-3O1模板√√√DL/T5210.1表3.0.12-2O1現澆混凝土結構模板安裝√√√DL/T5210.1表5.12.1O2鋼筋√√√DL/T5210.1表3.0.12-2O1鋼筋加工√√√DL/T5210.1表5.12.6O2鋼筋安裝√√√DL/T5210.1表5.12.8O3混凝土√√√DL/T5210.1表3.0.12-2O1混凝土原材料及拌合物√√√DL/T5210.1表5.12.9O2混凝土施工√√√DL/T5210.1表5.12.10O3混凝土結構外觀及尺寸偏差√√√DL/T5210.1表5.12.11O4磚砌體工程√√√DL/T5210.1表3.0.12-2O1填充墻砌體√√√DL/T5210.1表5.11.5O3建筑裝飾裝修√√√√√DL/T5210.1表3.0.12-301樓面與地面√√√DL/T5210.1表3.0.12-2O1基土質量√√√DL/T5210.1表5.17.1O2墊層√√√DL/T5210.1表5.17.2-2~6O3中間層處理√√√DL/T5210.1表5.17.3-1~4O4面層√√√DL/T5210.1表5.17.2-1~24O2抹灰√√√DL/T5210.1表3.0.12-2O1一般抹灰√√√DL/T5210.1表5.18.1O2保溫層薄抹灰√√√DL/T5210.1表5.18.2O3門窗√√√DL/T5210.1表3.0.12-2O1金屬門窗安裝√√√DL/T5210.1表5.20.2O2門窗玻璃安裝√√√DL/T5210.1表5.20.6O4建筑屋面√√√√√DL/T5210.1表3.0.12-3O1基層與保護√√√DL/T5210.1表3.0.12-2O1屋面找平層√√√DL/T5210.1表5.29.1O2保溫與隔熱√√√DL/T5210.1表3.0.12-2O1保溫層√√√DL/T5210.1表5.29.5O3防水與密封√√√DL/T5210.1表3.0.12-2O3屋面卷材防水層√√√DL/T5210.1表5.29.905建筑電氣√√√√DL/T5210.1表3.0.12-301室內電氣照明安裝工程√√√DL/T5210.1表3.0.12-201成套配電柜、控制柜(屏、臺)和動力、照明配電箱(盤)安裝√√√DL/T5210.1表5.33.102電線導管、電纜導管和線槽敷設安裝√√√DL/T5210.1表5.33.203電線、電纜穿管和線槽敷設√√√DL/T5210.1表5.33.304電纜頭制作、接線和線路絕緣測試√√√DL/T5210.1表5.33.605普通燈具安裝√√√DL/T5210.1表5.33.706專用燈具安裝√√√DL/T5210.1表5.33.807開關、插座、風扇安裝√√√DL/T5210.1表5.33.1008建筑物照明通電試運行√√√DL/T5210.1表5.33.1109接地裝置安裝√√√DL/T5210.1表5.33.1202防雷接地裝置安裝√√√DL/T5210.1表3.0.12-201接地裝置安裝√√√DL/T5210.1表5.33.1202避雷引下線安裝及接閃器安裝√√√DL/T5210.1表5.33.1306建筑節能工程√√√DL/T5210.1表3.0.12-301圍護系統節能√√√DL/T5210.1表3.0.12-201墻體節能工程√√√DL/T5210.1表5.35.102門窗節能工程 √√√DL/T5210.1表5.35.303屋面節能工程√√√DL/T5210.1表5.35.402電氣動力節能√√√DL/T5210.1表3.0.12-201配電與照明節能工程√√√DL/T5210.1表5.35.909儲能區域01地基與基礎工程√√√√√DL/T5210.1表3.0.12-301定位及高程控制√√√DL/T5210.1表3.0.12-201定位及高程控制√√√DL/T5210.1表5.2.102挖方√√√DL/T5210.1表3.0.12-201土(石)方開挖√√√DL/T5210.1表5.3.1~5.3.203填方√√√DL/T5210.1表3.0.12-201土方回填√√√DL/T5210.1表5.3.304土石方堆放√√√√√DL/T5210.1表3.0.12-201土石方堆放√√√DL/T5210.1表5.3.405墊層√√√DL/T5210.1表3.0.12-201墊層√√√DL/T5210.1表5.17.2-1~5.17.2-606基礎模板√√√DL/T5210.1表3.0.12-201模板安裝√√√DL/T5210.1表5.12.107基礎鋼筋√√√DL/T5210.1表3.0.12-201鋼筋加工√√√DL/T5210.1表5.12.602鋼筋安裝√√√DL/T5210.1表5.12.808基礎混凝土√√√DL/T5210.1表3.0.12-201混凝土原材料及拌合物√√√DL/T5210.1表5.12.902混凝土施工√√√DL/T5210.1表5.12.1003混凝土結構外觀尺寸偏差√√√DL/T5210.1表5.12.112安裝工程√√√√DL/T5161.1表5.0.31光伏區安裝工程√√√√DL/T5161.1表5.0.31#1方陣光伏發電單元安裝√√√√DL/T5161.1表5.0.21光伏支架安裝√√√√DL/T5161.1表5.0.21光伏支架安裝√√√GB50794表5.2.22電池組件安裝√√√√DL/T5161.1表5.0.21電池組件安裝√√√GB50794表5.3.23逆變器安裝√√√√DL/T5161.1表5.0.21逆變器安裝√√√GB50794表5.5.12逆變器帶電試運行√√√√DL/T5161.13表3.0.34箱式變壓器安裝√√√√DL/T5161.1表5.0.21安裝檢查√√√√DL/T5161.3表1.0.2、表1.0.6、表1.0.7、表1.0.102帶電試運√√√√DL/T5161.3表3.0.75電纜敷設工程√√√√DL/T5161.1表5.0.21電纜管配制與敷設√√√DL/T5161.5表1.0.22電纜敷設√√√DL/T5161.5表2.0.3DL/T5161.5表2.0.43電力電纜終端制作及安裝√√√DL/T5161.5表3.0.24電力電纜接頭制作及安裝√√√DL/T5161.5表3.0.35電纜防火及阻燃√√√DL/T5161.5表4.0.26防雷及接地裝置安裝√√√√DL/T5161.1表5.0.21接地裝置安裝√√√DL/T5161.6表1.0.22#2方陣光伏發電單元安裝√√√√DL/T5161.1表5.0.21光伏支架安裝√√√√DL/T5161.1表5.0.21光伏支架安裝√√√GB50794表5.2.22電池組件安裝√√√√DL/T5161.1表5.0.21電池組件安裝√√√GB50794表5.3.23逆變器安裝√√√√DL/T5161.1表5.0.21逆變器安裝√√√DL/T5161.13表2.0.22逆變器帶電試運行√√√√DL/T5161.13表3.0.34箱式變壓器安裝√√√√DL/T5161.1表5.0.21安裝檢查√√√√DL/T5161.3表1.0.2、表1.0.6、表1.0.7、表1.0.102帶電試運√√√√DL/T5161.3表3.0.75電纜敷設工程√√√√DL/T5161.1表5.0.21電纜管配制與敷設√√√DL/T5161.5表1.0.22電纜敷設√√√DL/T5161.5表2.0.3DL/T5161.5表2.0.43電力電纜終端制作及安裝√√√DL/T5161.5表3.0.24電力電纜接頭制作及安裝√√√DL/T5161.5表3.0.35電纜防火及阻燃√√√DL/T5161.5表4.0.26防雷及接地裝置安裝√√√√DL/T5161.1表5.0.21接地裝置安裝√√√DL/T5161.6表1.0.23#3方陣光伏發電單元安裝√√√√DL/T5161.1表5.0.21光伏支架安裝√√√√DL/T5161.1表5.0.21光伏支架安裝√√√GB50794表5.2.22電池組件安裝√√√√DL/T5161.1表5.0.21電池組件安裝√√√GB50794表5.3.23逆變器安裝√√√√DL/T5161.1表5.0.21逆變器安裝√√√DL/T5161.13表2.0.22逆變器帶電試運行√√√√DL/T5161.13表3.0.34箱式變壓器安裝√√√√DL/T5161.1表5.0.21安裝檢查√√√√DL/T5161.3表1.0.2、表1.0.6、表1.0.7、表1.0.102帶電試運√√√√DL/T5161.3表3.0.75電纜敷設工程√√√√DL/T5161.1表5.0.21電纜管配制與敷設√√√DL/T5161.5表1.0.22電纜敷設√√√DL/T5161.5表2.0.3DL/T5161.5表2.0.43電力電纜終端制作及安裝√√√DL/T5161.5表3.0.24電力電纜接頭制作及安裝√√√DL/T5161.5表3.0.35電纜防火及阻燃√√√DL/T5161.5表4.0.26防雷及接地裝置安裝√√√√DL/T5161.1表5.0.21接地裝置安裝√√√DL/T5161.6表1.0.24#4方陣光伏發電單元安裝√√√√DL/T5161.1表5.0.21光伏支架安裝√√√√DL/T5161.1表5.0.21光伏支架安裝√√√GB50794表5.2.22電池組件安裝√√√√DL/T5161.1表5.0.21電池組件安裝√√√GB50794表5.3.23逆變器安裝√√√√DL/T5161.1表5.0.21逆變器安裝√√√DL/T5161.13表2.0.22逆變器帶電試運行√√√√DL/T5161.13表3.0.34箱式變壓器安裝√√√√DL/T5161.1表5.0.21安裝檢查√√√√DL/T5161.3表1.0.2、表1.0.6、表1.0.7、表1.0.102帶電試運√√√√DL/T5161.3表3.0.75電纜敷設工程√√√√DL/T5161.1表5.0.21電纜管配制與敷設√√√DL/T5161.5表1.0.22電纜敷設√√√DL/T5161.5表2.0.3DL/T5161.5表2.0.43電力電纜終端制作及安裝√√√DL/T5161.5表3.0.24電力電纜接頭制作及安裝√√√DL/T5161.5表3.0.35電纜防火及阻燃√√√DL/T5161.5表4.0.26防雷及接地裝置安裝√√√√DL/T5161.1表5.0.21接地裝置安裝√√√DL/T5161.6表1.0.25#5方陣光伏發電單元安裝√√√√DL/T5161.1表5.0.21光伏支架安裝√√√√DL/T5161.1表5.0.21光伏支架安裝√√√GB50794表5.2.22電池組件安裝√√√√DL/T5161.1表5.0.21電池組件安裝√√√GB50794表5.3.23逆變器安裝√√√√DL/T5161.1表5.0.21逆變器安裝√√√DL/T5161.13表2.0.22逆變器帶電試運行√√√√DL/T5161.13表3.0.34箱式變壓器安裝√√√√DL/T5161.1表5.0.21安裝檢查√√√√DL/T5161.3表1.0.2、表1.0.6、表1.0.7、表1.0.102帶電試運√√√√DL/T5161.3表3.0.75電纜敷設工程√√√√DL/T5161.1表5.0.21電纜管配制與敷設√√√DL/T5161.5表1.0.22電纜敷設√√√DL/T5161.5表2.0.3DL/T5161.5表2.0.43電力電纜終端制作及安裝√√√DL/T5161.5表3.0.24電力電纜接頭制作及安裝√√√DL/T5161.5表3.0.35電纜防火及阻燃√√√DL/T5161.5表4.0.26防雷及接地裝置安裝√√√√DL/T5161.1表5.0.21接地裝置安裝√√√DL/T5161.6表1.0.20202升壓站設備安裝調試√√√√DL/T5161.1表5.0.301主變壓器系統設備安裝√√√√DL/T5161.1表5.0.201主變壓器安裝√√√√DL/T5161.1表5.0.201主變壓器本體安裝√√√DL/T5161.3表1.0.602主變壓器器身檢查√√√√DL/T5161.3表1.0.703主變壓器附件安裝√√√DL/T5161.3表1.0.804主變壓器注油、熱油循環及密封試驗√√√DL/T5161.3表1.0.905主變壓器整體檢查√√√DL/T5161.3表1.0.1002主變壓器系統附屬設備安裝√√√√DL/T5161.1表5.0.201中性點隔離開關安裝√√√DL/T5161.2表5.0.202中性點避雷器安裝√√√DL/T5161.2表6.0.203中性點電流互感器安裝√√√DL/T5161.3表2.0.204控制柜及端子箱檢查安裝√√√DL/T5161.8表3.0.205軟母線安裝√√√DL/T5161.4表7.0.206矩形母線安裝√√√DL/T5161.4表3.0.203主變壓器帶電試運√√√√DL/T5161.3表3.0.702主控及直流設備安裝√√√√DL/T5161.1表5.0.301主控室設備安裝√√√√DL/T5161.1表5.0.201控制及保護和自動化屏安裝√√√DL/T5161.8表4.0.202直流屏及不間斷電源設備安裝√√√DL/T5161.13表2.0.203二次回路檢查及接線√√√DL/T5161.8表5.0.202蓄電池組安裝√√√√DL/T5161.1表5.0.201蓄電池安裝√√√DL/T5161.9表1.0.2DL/T5161.9表2.0.202充放電及容量測定√√√DL/T5161.9表3.0.20335kV配電裝置安裝√√√√DL/T5161.1表5.0.301主母線及旁路母線安裝√√√√DL/T5161.1表5.0.201矩形母線安裝√√√DL/T5161.4表3.0.202接地開關安裝√√√DL/T5161.2表5.0.202電壓互感器及避雷器安裝√√√√DL/T5161.1表5.0.201避雷器安裝√√√DL/T5161.2表6.0.202電壓互感器安裝√√√DL/T5161.3表2.0.303箱柜安裝√√√DL/T5161.81.0.210.135kV配電裝置帶電試運√√√√DL/T5161.1表6.0.404110kV氣體絕緣金屬封閉開關設備安裝√√√√DL/T5161.1表5.0.301氣體絕緣金屬封閉開關設備安裝√√√√DL/T5161.1表5.0.201基礎檢查及設備支架安裝√√√DL/T5161.2表1.0.202氣體絕緣金屬封閉開關設備本體安裝√√√DL/T5161.2表1.0.302配套設備安裝√√√√DL/T5161.1表5.0.201軟母線安裝√√√DL/T5161.4表7.0.203就地控制設備安裝√√√√DL/T5161.1表5.0.201控制柜及就地箱安裝√√√DL/T5161.8表3.0.202二次回路檢查及接線√√√DL/T5161.8表5.0.204110kV氣體絕緣金屬封閉開關設備帶電試運√√√√DL/T5161.2表9.0.60535kV及站用配電裝置安裝√√√√DL/T5161.1表5.0.301變壓器安裝√√√√DL/T5161.1表5.0.201變壓器本體安裝√√√DL/T5161.3表1.0.602變壓器器身檢查√√√DL/T5161.3表1.0.703變壓器附件安裝√√√DL/T5161.3表1.0.804變壓器整體檢查√√√DL/T5161.3表1.0.1002400V站用低壓配電裝置安裝√√√√DL/T5161.1表5.0.201低壓變壓器安裝√√√DL/T5161.3表1.0.203二次回路檢查接線√√√DL/T5161.8表5.0.20335kV系統設備帶電試運√√√√DL/T5161.1表6.0.504400V系統設備帶電試運√√√√、DL/T5161.1表6.0.606無功補償裝置安裝√√√√DL/T5161.1表5.0.301電抗器安裝√√√√DL/T5161.1表5.0.201隔離開關安裝√√√DL/T5161.2表5.0.202電抗器安裝√√√DL/T5161.2表4.0.203母線安裝√√√DL/T5161.4表7.0.210無功補償裝置帶電試運√√√√DL/T5161.2表9.0.707全站電纜施工√√√√DL/T5161.1表5.0.301電纜管配制及敷設√√√√DL/T5161.1表5.0.201電纜管配制及敷設√√√DL/T5161.5表1.0.202電纜支架(橋架)配制及安裝√√√√DL/T5161.1表5.0.201電纜支架(橋架)安裝√√√DL/T5161.5表1.0.303電纜敷設√√√√DL/T5161.1表5.0.201屋內電纜敷設√√√DL/T5161.5表2.0.202屋外電纜敷設√√√DL/T5161.5表2.0.304電力電纜終端及中間接頭制作√√√√DL/T5161.1表5.0.201電力電纜終端制作及安裝√√√DL/T5161.5表3.0.205控制電纜終端制作及安裝√√√√DL/T5161.1表5.0.201控制電纜終端制作及安裝√√√DL/T5161.5表3.0.406電纜防火與阻燃√√√√DL/T5161.1表5.0.201電纜防火與阻燃√√√DL/T5161.5表4.0.208全站防雷及接地裝置安裝√√√√DL/T5161.1表5.0.301避雷針及引下線安裝√√√√DL/T5161.1表5.0.201避雷針及引下線安裝√√√DL/T5161.6表3.0.202接地裝置安裝√√√√DL/T5161.1表5.0.201屋外接地裝置安裝√√√DL/T5161.6表1.0.202屋內接地裝置安裝√√√DL/T5161.6表2.0.203電氣二次系統等電位接地裝置安裝√√√DL/T5161.6表4.0.209通信工程安裝√√√√DL/T5161.1表5.0.301光纖通信設備安裝√√√√DL/T5161.1表5.0.201機架安裝√√√DL/T5161.11表6.0.202通信設備安裝√√√DL/T5161.11表4.0.203站內通信光纜安裝√√√DL/T5161.11表7.0.202通信系統防雷接地安裝√√√√DL/T5161.1表5.0.201通信站(系統)防雷接地安裝√√√DL/T5161.11表8.0.210儲能設備安裝01儲能蓄電池倉安裝√√√√DL/T5161.1表5.0.201箱柜安裝√√√DL/T5161.81.0.202二次回路檢查及接線√√√DL/T5161.8表5.0.202變壓器安裝√√√√DL/T5161.1表5.0.201變壓器本體安裝√√√DL/T5161.3表1.0.602變壓器器身檢查√√√DL/T5161.3表1.0.703變壓器附件安裝√√√DL/T5161.3表1.0.804變壓器整體檢查√√√DL/T5161.3表1.0.1003400V站用低壓配電裝置安裝√√√√DL/T5161.1表5.0.201低壓變壓器安裝√√√DL/T5161.3表1.0.203二次回路檢查接線√√√DL/T5161.8表5.0.20435kV系統設備帶電試運√√√√DL/T5161.1表6.0.505400V系統設備帶電試運√√√√DL/T5161.1表6.0.603場內電力線路工程√√√√GB50173-2014表D.0.25011路35kV場內電力線路工程√√√√GB50173-2014表D.0.2401土石方工程√√√√GB50173-2014表D.0.2401路徑復測√√√GB50173-2014表D.0.102普通(掏挖)和拉線基礎分坑√√√GB50173-2014表D.0.202基礎工程√√√√GB50173-2014表D.0.2401鋼管塔、鐵塔基礎(澆筑前)√√√GB50173-2014表D.0.5、表D.0.2002鋼管塔、鐵塔基礎(澆筑后)√√√GB50173-2014表D.0.6、表D.0.2003桿塔工程√√√√GB50173-2014表D.0.2401自立式鐵塔組立√√√GB50173-2014表D.0.8、表D.0.2104架線工程√√√√GB50173-2014表D.0.2401導地線(含光纜)展放√√√GB50173-2014表D.0.11、表D.0.2302導地線接續管√√√GB50173-2014表D.0.12、表D.0.2303導地線(含光纜)緊線√√√GB50173-2014表D.0.13、表D.0.2304附件安裝(含光纜)√√√GB50173-2014表D.0.14、表D.0.2205接地工程√√√√GB50173-2014表D.0.2401接地裝置施工√√√GB50173-2014表D.0.1706線路防護工程√√√√GB50173-2014表D.0.2401線路防護設施√√√GB50173-2014表D.0.1907電氣工程√√√√GB50173-2014表D.0.2401光纜測試√√√GB50173-2014表D.0.1502對地、風偏與交叉跨越√√√GB50173-2014表D.0.1603桿上電氣設備√√√GB50173-2014表D.0.1808電力電纜線路工程√√√√DL/T5161.1表5.0.301電纜管配制及敷設√√√DL/T5161.5表1.0.202電纜支架(橋架)安裝√√√DL/T5161.5表1.0.303電纜敷設√√√DL/T5161.5表2.0.3DL/T5161.5表2.0.404電力電纜終端制作及安裝√√√DL/T5161.5表3.0.205電力電纜接頭制作及安裝√√√DL/T5161.5表3.0.306電纜防火與阻燃√√√DL/T5161.5表4.0.207光纜安裝√√√DL/T5161.11表7.0.208光纜測試√√√GB50173表D.0.15022路35kV場內電力線路工程√√√√GB50173-2014表D.0.24~NN回路35kV場內電力線路工程√√√√GB50173-2014表D.0.24注:2回路35kV場內電力線路工程~N回路35kV場內電力線路工程質量驗收范圍劃分內容按照集電線路1回路35kV場內電力線路工程進行(共N個回路)。04110kV~750kV送出線路工程√√√√√DL/T5168表C.0.20100土石方工程√√√√√√DL/T51686表C.0.101路徑復測√√√DL/T5168表4.2.2、表A.0.102普通基礎分坑及開挖√√√DL/T51684.2.3A.0.203拉線基礎分坑及開挖√√√DL/T51684.2.4A.0.204巖石、掏挖基礎分坑及開挖√√√DL/T51684.2.5A.0.305施工基面及電氣開方√√√DL/T51684.2.6A.0.40200基礎工程√√√√√DL/T5168表C.0.101現澆鐵塔基礎施工√√√DL/T
溫馨提示
- 1. 本站所有資源如無特殊說明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請下載最新的WinRAR軟件解壓。
- 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請聯系上傳者。文件的所有權益歸上傳用戶所有。
- 3. 本站RAR壓縮包中若帶圖紙,網頁內容里面會有圖紙預覽,若沒有圖紙預覽就沒有圖紙。
- 4. 未經權益所有人同意不得將文件中的內容挪作商業或盈利用途。
- 5. 人人文庫網僅提供信息存儲空間,僅對用戶上傳內容的表現方式做保護處理,對用戶上傳分享的文檔內容本身不做任何修改或編輯,并不能對任何下載內容負責。
- 6. 下載文件中如有侵權或不適當內容,請與我們聯系,我們立即糾正。
- 7. 本站不保證下載資源的準確性、安全性和完整性, 同時也不承擔用戶因使用這些下載資源對自己和他人造成任何形式的傷害或損失。
最新文檔
- 學校應急疏散演練計劃
- 2024-2025學年山東省淄博市周村區八年級上學期期中考試地理試卷
- 竺可楨學校教育集團八年級第一學期科學期中試卷
- 工廠安全文明生產費使用計劃
- 2024-2025學年四川省達州市通川區達州鐵路中學七年級上學期期中檢測地理試卷
- 永康市第一學期九年級期末學業水平監測 科學試題卷
- 部編版三年級語文下冊詞匯積累計劃
- 醫療行業員工試用期轉正談話記錄范文
- 2025年數據安全管理計劃
- 稅務資產評估實習經驗總結范文
- 《離散數學》題庫答案
- 口腔種植手術協議書
- 小學英語-國際音標-練習及答案
- 2025-2030年國有銀行行業市場深度分析及競爭格局與投資發展研究報告
- 2025年建筑模板制品行業深度研究報告
- 掛名股東簽署協議書
- 2025國家開放大學《員工勞動關系管理》形考任務1234答案
- 湖北省荊門市2025年七年級下學期語文期末考試試卷及答案
- 環境監測中的化學分析技術試題及答案
- 2024-2025湘科版小學科學四年級下冊期末考試卷及答案(三套)
- 下肢深靜脈血栓的預防和護理新進展
評論
0/150
提交評論