1、Directory TOC o 1-5 h z HYPERLINK l bookmark0 o Current Document preface2safe note3一.function and feature4function4feature4二、instruction5design basis5. characteristic 5technical index5LEDindicated5The front ,bottom of controller 6wire connection instruction 6三、 design requirement6afety level 6securi

2、ty7四、installation7 HYPERLINK l bookmark22 o Current Document install mode7install angle 9terminal rod/insulator install 9middle rod/insulator install10middle pull rod/insulator install10tensioner install104.7lightning-arrester10alloy wire connection11grounding11ground wirin g11五、controller install &

3、connection11controller install11controller and fence connection 12六、debug and alarm test12electrify check 12 HYPERLINK l bookmark36 o Current Document alarm test 12七、install rule & security note 15install rule 15safety note and some removing methods 16Prefaceshanghai Yi Section Company is specialize

4、d in manufacturing electric security fence with its own R&D department factory located in Shenzhen. Yi Section company persistently follows the principledo everything with whole hearted, through superior quality and zealous service, Yi Section tries every efforts to respond the users that gives us l

5、ong-term support and trust.Pulse electric fence energizer and perimeter accessory that Yi Sectionproducts and develops conforming to therequirements of GB/T7946-2008pulse electric fence installation and safe operation and meet CEI-61011 internationalelectric fence standard. The patent water proof ca

6、sing design, professional output method, advanced difference voltage output technology, unique LCD display function, makethe products as the leader in the industry. The products sell to UniteStates, Europe, Australia, Africa, and Asian country , Yi Sectionwill be the base of international production

7、 and service. Theproducts are widely used in ware house, industry areas, power station, private house, villa, school, car parks, plant areas, airpot, prison, military base.etc.Security note:Unless high/low voltage output disarmed of electric fence,don t touch the conductor part of the system.Don t i

8、nstall electric fence during the thunder, dod t install controller in moist place.Before install and use the product, do the safe educational technology training work.During the installation, in order to use normally in future, follow the instructions to make sure the grounding of products. Refer to

9、 4.9 item ”When the product is electrified , the inside of controller is 220v 50Hz AC current, 5-10KV high voltage pulse on the output port and electric fence, dori t touch it to make sure security.don t bear any responsibility if any accident arise.The user must know the related electric device kno

10、wledge, and read the user instruction and operate it carefully before install it with correct use methods, otherwise , our side Once abnormal case happen, should make sure the power off, then professional staffs check and analysisrepair or contact our company, don t repack it by your own.一.Function

11、and featureThere are two kinds of existing security products. One kind is a fence, like traditional brick wall, cement wall, glass wall, iron fence and so on, has the obvious contours, encircles the defense area, has the impediment external invasion function, but does not have the alarm and the surv

12、eillance function. Another kind is the alarm system, like the infrared correlation alarm apparatus, divulge electric cable, CCTV and so on, they have the alarm or the surveillance function, but does not have the impediment function.The smart pulse electric fence system integrate the prevents and ala

13、rm functions together, and increase thehigh voltagedeterrent effect, not only have visible fence, but also have smart multi-zone controller, the alarm system becomes brand new perimeter security system.system functionhave complete and explicit dividing line fence,and formidable impediment and deter

14、function.have low rate of false alarm function,when the outer fence alarm,the display windows rapidly display which zonesuffers break,short-circuit and tamper, reflect the current condition.The DC 12V alarm connection,dry contact signal output, can linkage with other security system, improve the sys

15、tem s safe rank.distinction function of electric fence and can detect all kinds of invasion rank, can differentiate the accidental invadefrom forceful invade ability.The accidental intruder see the alarm or suffer from the electric shock, the leave, the alarm apparatus do not send out alarm.The intr

16、uder invade forcefully , so that the electric fence will be destroyed, in this case, the system will send out alarm. Onlythe intruder really invade and destroy the system, then will send alarm, will not alarm mistakenly and fails to alarm.system featureAbsolute safety and alarm perceiveThe tradition

17、al high voltage pulse electric net system doesnt have alarm perceive function, only through high voltage, strongcurrent to impediment intruder. It is very easy to get intruder disable, even dies and so serious results. The smart pulse electric fence system adopts low energy pulse high voltage( 5 10K

18、V ) ,because the energy is extremely low,the responsetime is extremely short, will not cause the damage to the humanbody. Once touched, will just leave dut to electric shock.1.2.2The low rate of false alarmand strong AdaptabilityThe smart pulse electric fence system is not affected by environment (f

19、or example. trees, animals, shake.etc ) and climate ( wind, snow, rain and fog,etc) and not limited by terrain height and winding degree. The rate of false alarm is very low.impediment and alarm dual functionThe new concept of smart pulse electric fence system is to prevent the intruder out of from

20、the fence area,without the crime is the goal, give the intruder one kind of deterrent feeling and impediment function, dare not act rashly, achieve the security, reduces the crime.continuous work,set armed/disarmed .use the 12V/4Ah battery as backup power supply,when the power supply is off,can work

21、 continually.According to user s request and site geographical environment, carry out the design and installation, and work with multiple modern security products, such as CCTV monitored system, television supervisory system and GSM system to improve the system security ranks.Absolute safety, confor

22、ms to the international CE certification and is also in conformity with IEC 60335-2-76 and the GB/T7946-2008 request, and get approved from public security form test.二、product instructionsproduct design basis:GB/T7946-2008 Pulse electric fence installation And Safe operationproduct characteristic:di

23、fference voltage output technology: every wire has voltage, have the differential voltage between thetwo adjacentwires.LCD display the monitor state indicating the voltage on every wire.high/low voltage switch manually, long-distance equipment auto switch function.short circuit, break and tamper ala

24、rm, equipment faultauto-detect. waterproof casing and downward appearance design guiding the industry development.4RS 485 main line control, keypad, computer, network and multiple long distance management solution.DC12V, open/close dry contact alarm output, can work with other modern security produc

25、duct technical indexpower supply:AC180V-240v50Hzuse environmentTemperature : -40-+50 Cmoisture: : 95%output index:Output peak voltage: 5KV 10KVOutput low voltage:7001000VPeak current of pulse: 10APulse duration : 0.1sPulse interval time: 1sMax quantity of electricity of pulse : 2.5mCMax energy

26、 of pulse : 5.0JSystem power consumption: 10wLED indicated lamp condition instructions:is bright.ac 220v or dc12v,when power supply input ,the green indicated lampwhen armed,the yellow indicated lamp is bright. when disarmed,it shows off.when alarm break,the red indicated lamp is bright.when alarm s

27、hort circuit,the red indicated lamp is brightwhen open cover, the red indicated lamp of tamper is bright.the front and bottom of controller instructions.底部摟找圖 I HAJkB-MAFKKMIiUiZ 碣3此the wire connection of controller instruction( above drawing)the controller comprise two parts: input and output,the p

28、ositive pulse from output part1st line high voltage output port transfer to fence wire, then return back to the receiver part15t line high voltage input port ,negative pulse from output 2nd linehigh voltage output port transfer to fence wire, then return back to the receiver part 2nd line high volta

29、ge input port ,so formpositive and negative pulse closed circuit on the front fence.high voltage earth output: can share the same earth output with lightning arrester, strong/weak earth separate.voltage switch: use for switching high/low voltage mode or automatic working mode.keypad output: can conn

30、ect keypad directly or RS485 transfer RS 232,then connect to computer by long distancecontrol, The RS 485 connection of each controller needs to go hands by hands connection, multiple connection is not allowed.switch output: output open/close dry contact signal, needs to connect with other linkage d

31、evice.alarm output: when alarm, output DC 12V voltage, connect with alarm device DC 12v below 10W.power switch: control the energizer on/off.power supply input: connect AC 220V power source.三、design request of electric fence3.1 according to different security rank, configurate suitable electric fenc

32、e,usually divide intoI、 n、III the three rank.I - general security rank, uses 4 lines system, the monitor zone partition does not surpass 500 meters. n - medium security rank, uses 8 lines system, the monitor zone partition does not surpass 250 meters.III higher security rank, uses 12 lines system, t

33、he monitor zone partition does not surpass 100 meters.Every zone must configurate independent controller, and have different triggered alarm apparatus, can indicate the alarm zone number. The alarm output usually linkage with CCTV, red-infrared correlation, spotlight, alarm apparatus etc. When appli

34、ed, the length of monitor zone should set according to the perimeter total length, the terrain and the objective site environment.3.2 Securitydont allow get the AC power supply on electric fence. when the product gets faulty, please make sure the electric fence without any AC power duct us

35、ed the rectification voltage dropping DC 12V, then voltage-rise to condenser charge, finally electric capacity pulse discharge boosting transformer, the output energy is limited by rectification, primary voltage-rise, electric capacitance discharge, so many links, without harm to human body and abso

36、lute safety.association factor and the influence of electric shock:The electric pulse will not injure the intruder, to avoid the associated responsibility, firstly, electric fence warning signs should hang up at every other 10 meters striking position noted ” electric fence, forbid climbing ,secondl

37、y, the height of electric fence should be above 1.8meters, if the height of electric fence is not high, should install isolated netting or wall to avoid accident.electric fence should not be with other power circuit and telecommunication wires on the same pole.electric fence should keep a certain sa

38、fe distance from the power circuit. The minimum distance as shown in the table 3-1Electric cable voltage rankhorizontal distance with electric fencevertical distance with electric fence10KV below2.5m2m35110KV5m3m220KV7m4m330KV9m5m500KV9m5mhorizontal distance between electric fence and public rod bor

39、der should be above 5m( except the electric fence on top of the wall)electric fence has pulse high voltage, when bad connection or close to charged conductor, will have fire spark. Thus, electric fence should install without any flammable gas, and without any flammable fluid place. According7to the

40、related national standard, keep enough safe distance, or take the safe measures to isolate.When inspect the place to install electric fence, pls make sure the electric fence without any conflict with the electric wire, pipeline from the ground. And without any sundry goods at nearby place, whether t

41、he electric fence is influenced strongly by transmitting station and other high frequency device. If have, must mark the signal wire with STP shielded twisted pair at the construction drawing.四、 Electric fence installinstall mode:. 1 install on top of the wall.Install the electric fence on top of wa

42、ll, the height of fence wall should be above 1.8meters, the wire pole/rod may have welding ,clip or buried the three modes, should choose suitable mode according to the fence structure condition. For example, install at the steel fence, can take the welding, install at the concrete wall, can take bu

43、ried mode to make sure stable, artistic, may use other modes also.2 The attached installThe installation attaches on the fence or top or inside, the fence wall directly withstanding the pressure and wire tension, before installation, pls make sure the structural strength of the wall, if unreliable,

44、should reinforce in advance. The metallic conductor wire from the front end of electric fence spacing to the wall should be smaller than 700mm.4.1.3 stand alone electric fenceInstall the electric fence around the building, because the height is above 1800mm, the wire number reaches 8-20, the strengt

45、h of the wire to the terminal rod/pull rod tensity must be big, hence, terminal rod/ pull rod must have enough strength, and the embedment must be stable. If the soil is solid, may directly bury the wire of terminal rod and pull rod ends to underground 60cm to do fixed. If the rigidity of terminal w

46、iring rod is insufficient, should increase the support rod. Although the middle pull rod does not withstand the tensity of wire, but must support the pressure of multiple wires. Therefore, also needs to install it stably.May take buried mode installation. Follow the chart 12 wires stand alone instal

47、lation.4.2 electric fence installation angle: ( the angle with wall) see the right drawing.according to the site condition and the first party request( (0、22.5 1 45、67.5 1 90、112.5 ; 135、157.5 ;180) and the inclined direction( inclination angle, camber angle, vertical or horizontal ) installation.4.

48、2.2 according to the perimeter condition: if resident area, school nearby, suggested by inclination angle or vertical installation, spacious area suggested to install by camber angle, if the height of wall is above 2.5meters, take horizontal installation.犀配安裝安裝垂直安裝4.2.3 According to the protection o

49、bject: if prevent from outside invasion, suggest camber angle installation, ifprevent from interior climbing, suggestinclination angle installation.4.3 terminal rod/terminal rod insulator installationFix the terminal rod insulator on the terminal rod through terminal insulator clip, considering the

50、distance is longer, the pulling strength is bigger, every 100 meters or big corner and divided zone must be set a terminal rod, see the right drawing):終若肝安找曲t用靶)時圖I行wr樸M處終端行逐畿圖middle pull rod/middle pull rod insulator installation.The middle pull insulator assembles on the rod through screws or use

51、pinlock to fix it. Should note thedirection of installing, usually every 20 meters to set a middle pull rod. See the right drawing:tensioner installationThe middle tensioner usually hang on the front of electric fence,when install alloy wire, penetrates the wire from the tensioner sides round hole,

52、aim and pass the middle hole, finally gets out from another side round hole. See the chart. Note, dont make the tight line excessive, heat expanded and cold contracted, it maybe break in winter weather.lightning arrester installationFirstly fix the lightning arrester on the top of terminal rod,then

53、through the own nuts fixing on the frame, the lightning arrester usually installs on top of pulse energizer, every zone must install two lightning arresters.a lloy wire connectionConnect it by wire linker, need connect the lead end to penetrate the wire linker, then use nut to contract wire in the w

54、ire linker. See the right drawing:warning signs installationAccording to the condition, every 10 meters set as one warning signs.Grounding/earthgrounding request: according to GB/T 79462008,earth principle and weak electricity separated. The electric fence system includes: controller high voltage ou

55、tput earth, lighting arrester earth, protective earth output, the three kinds of earth. High voltage earth and lightning arrester earth can share the same earth, but must separate from protective earth, and the earth pole distance is above 10meters, the earth pole depth of burying is above 1.5m, the

56、 resistance value of weak electricity should be below 4Q, the resistance of high voltage earth should be belowio ,the lightning arrester earth connects reliably by square millimeter copper wires.Ounderground wire layoutelectric fence needs underground wirelayout,needs the rated voltage 15KV high vol

57、tage insulated conductor, penetrate the insulated threading tube.electric fence underground layout, should avoid high voltage insulated conductor,as the underground is usually moist, it is hard to keep good insulation strength at the tie-in. if tie-in avoidless, should strengthen the tie-in part ins

58、ulativity, for example, use the Silastic envelope, or change the tie-in above the ground.五、 The installation and connection of controllerinstallation of controllerthe controller fixed on approaching the initial station of zone or place of divided zone, or put in the control center or guard gate, if

59、install outdoor,need rainproof box.L警號3、媒惕兒J,阻子IB-*M *,川比根5、理*升 &7,搏相脩* f 中響地厚廣Q.中間H2.威力討班生子I I ,中間票打?qū)?、警求彈中M性髯世2、算一直證極器1工提地經(jīng)門巾壽興明合金德 b工U向9膝 懂,蛾也和城倚桂地1%弱電接Jt the connection drawing of controller and fence5.2.2refer to the above drawing, connect the electric fence to bottom port of controller, the to

60、p two wires must go through lightning arrester and connect 1st line output and 2nd output“ two sending port, the end port of fence 1 and 3, port 2 and 4,needs high voltage insulated wire short circuit, other connection mode depends on the condition.the wire connection of controller refers to above d

溫馨提示

  • 1. 本站所有資源如無特殊說明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請下載最新的WinRAR軟件解壓。
  • 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請聯(lián)系上傳者。文件的所有權(quán)益歸上傳用戶所有。
  • 3. 本站RAR壓縮包中若帶圖紙,網(wǎng)頁內(nèi)容里面會有圖紙預(yù)覽,若沒有圖紙預(yù)覽就沒有圖紙。
  • 4. 未經(jīng)權(quán)益所有人同意不得將文件中的內(nèi)容挪作商業(yè)或盈利用途。
  • 5. 人人文庫網(wǎng)僅提供信息存儲空間,僅對用戶上傳內(nèi)容的表現(xiàn)方式做保護(hù)處理,對用戶上傳分享的文檔內(nèi)容本身不做任何修改或編輯,并不能對任何下載內(nèi)容負(fù)責(zé)。
  • 6. 下載文件中如有侵權(quán)或不適當(dāng)內(nèi)容,請與我們聯(lián)系,我們立即糾正。
  • 7. 本站不保證下載資源的準(zhǔn)確性、安全性和完整性, 同時也不承擔(dān)用戶因使用這些下載資源對自己和他人造成任何形式的傷害或損失。

評論

0/150

提交評論